Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor

被引:58
|
作者
Nasirizadeh, Navid [1 ]
Zare, Hamid R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd 89195741, Iran
关键词
Noradrenalin; Acetaminophen; Differential pulse voltammetry; Biosensor; Hematoxylin; GLASSY-CARBON ELECTRODE; ADENINE-DINUCLEOTIDE NADH; ASCORBIC-ACID; URIC-ACID; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; DERIVATIVE SPECTROPHOTOMETRY; PHARMACEUTICAL FORMULATIONS; ELECTROCHEMICAL PROPERTIES; MASS-SPECTROMETRY;
D O I
10.1016/j.talanta.2009.07.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L-1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, alpha, the catalytic electron transfer rate constant, k', and the standard catalytic electron transfer rate constant, k(0), for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 x 10(-1) to 65.40 mu mol L-1 and 65.40-274.20 mu mol L-1 of NA, and for 12.00-59.10 mu mol L-1 and 59.10-261.70 mu mol L-1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 +/- 0.03 mu A for an electrolyte solution containing 5.00 mu mol L-1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [31] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Hadi Beitollahi
    Alireza Mohadesi
    Mortaza Mostafavi
    Hassan Karimi-Maleh
    Mehdi Baghayeri
    Ali Akbari
    Ionics, 2014, 20 : 729 - 737
  • [32] Differential Pulse Voltammetric Detection of Acetaminophen Using Nickel Phthalocyanine/CeO2-Modified ITO Electrodes
    Gomes, Emiliano C.
    Ribeiro, Camila L.
    Santos Jr, Vianney O.
    Paterno, Leonardo G.
    CHEMOSENSORS, 2023, 11 (03)
  • [33] Differential pulse voltammetric determination of trace rotenone using molecularly imprinted polymer microspheres
    Yang, Ming
    Chen, Yuantao
    Ma, Jing
    Huai, Lufeng
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 95 - 99
  • [34] Differential pulse voltammetric determination of trace rotenone using molecularly imprinted polymer microspheres
    Ming Yang
    Yuantao Chen
    Jing Ma
    Lufeng Huai
    Microchimica Acta, 2009, 166 : 95 - 99
  • [35] Differential pulse voltammetric determination of 8-aminoquinoline using carbon paste electrode
    Stoica, AI
    Zima, J
    Barek, J
    ANALYTICAL LETTERS, 2005, 38 (01) : 149 - 156
  • [36] Differential pulse voltammetric determination of acyclovir in pharmaceutical preparations using a pencil graphite electrode
    Dilgin, Didem Giray
    Karakaya, Serkan
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 570 - 576
  • [37] A differential pulse voltammetric determination of nisoldipine using glassy carbon electrode in pharmaceutical preparations
    Dogrukol-Ak, D
    Gökören, N
    Tunçel, M
    ANALYTICAL LETTERS, 1998, 31 (01) : 105 - 116
  • [38] Simultaneous quantitative determination of diazepam and liposomes using differential pulse polarography
    Kontoyannis, CG
    Antimisiaris, SG
    Douroumis, D
    ANALYTICA CHIMICA ACTA, 1999, 391 (01) : 83 - 88
  • [39] Simultaneous voltammetric determination of molybdenum and copper by adsorption cathodic differential pulse stripping method using a principal component artificial neural network
    Ensafi, AA
    Khayamian, T
    Atabati, M
    TALANTA, 2002, 57 (04) : 785 - 793
  • [40] RAPID DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF 7-METHYLGUANINE
    SEQUARIS, JM
    VALENTA, P
    NURNBERG, HW
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 122 (MAY) : 263 - 268