Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor

被引:58
|
作者
Nasirizadeh, Navid [1 ]
Zare, Hamid R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd 89195741, Iran
关键词
Noradrenalin; Acetaminophen; Differential pulse voltammetry; Biosensor; Hematoxylin; GLASSY-CARBON ELECTRODE; ADENINE-DINUCLEOTIDE NADH; ASCORBIC-ACID; URIC-ACID; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; DERIVATIVE SPECTROPHOTOMETRY; PHARMACEUTICAL FORMULATIONS; ELECTROCHEMICAL PROPERTIES; MASS-SPECTROMETRY;
D O I
10.1016/j.talanta.2009.07.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L-1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, alpha, the catalytic electron transfer rate constant, k', and the standard catalytic electron transfer rate constant, k(0), for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 x 10(-1) to 65.40 mu mol L-1 and 65.40-274.20 mu mol L-1 of NA, and for 12.00-59.10 mu mol L-1 and 59.10-261.70 mu mol L-1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 +/- 0.03 mu A for an electrolyte solution containing 5.00 mu mol L-1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [21] Differential Pulse Voltammetric Determination of Paraquat Using a Bismuth-Film Electrode
    de Figueiredo-Filho, Luiz Carlos S.
    dos Santos, Vagner B.
    Janegitz, Bruno Campos
    Guerreiro, Thiago Brito
    Fatibello-Filho, Orlando
    Faria, Ronald Censi
    Marcolino-Junior, Luiz Humberto
    ELECTROANALYSIS, 2010, 22 (11) : 1260 - 1266
  • [22] DIRECT DETERMINATION OF ACETAMINOPHEN IN PLASMA BY DIFFERENTIAL PULSE VOLTAMMETRY
    MUNSON, JW
    ABDINE, H
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1978, 67 (12) : 1775 - 1776
  • [23] Differential pulse anodic stripping voltammetric determination of endosulfan
    Mathew, L
    Reddy, MLP
    Rao, TP
    Iyer, CSP
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1998, 37 (11): : 1027 - 1028
  • [24] Differential pulse voltammetric determination of nitrite with gold ultramicroelectrode
    da Silva, SM
    Mazo, LH
    ELECTROANALYSIS, 1998, 10 (17) : 1200 - 1203
  • [25] Differential pulse cathodic voltammetric determination of floctafenine and metopimazine
    Gazy, Azza A.
    Hassan, Ekram M.
    Abdel-Hay, Mohamed H.
    Belal, Tarek S.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1535 - 1539
  • [26] Differential Pulse Voltammetric Determination of Nitrite with Gold Ultramicroelectrode
    Departamento de Química, Instituto de Biociências, UNESP, Caixa Postal 510, CEP 18618-000, Botucatu, SP, Brazil
    不详
    Electroanalysis, 17 (1200-1203):
  • [27] DIFFERENTIAL PULSE ADSORPTIVE VOLTAMMETRIC DETERMINATION OF CHROMIUM IN ALUMINUM
    SARNAIK, KM
    PALRECHA, MM
    DHANESHWAR, RG
    ELECTROANALYSIS, 1989, 1 (05) : 469 - 471
  • [28] Simultaneous Differential Pulse Voltammetric Determination of Ascorbic Acid and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2010, 22 (15) : 1717 - 1723
  • [29] Application of orthogonal functions to differential pulse voltammetric analysis - Simultaneous determination of tin and lead in soft drinks
    Sabry, SM
    Wahbi, AAM
    ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) : 173 - 183
  • [30] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Beitollahi, Hadi
    Mohadesi, Alireza
    Mostafavi, Mortaza
    Karimi-Maleh, Hassan
    Baghayeri, Mehdi
    Akbari, Ali
    IONICS, 2014, 20 (05) : 729 - 737