Differential pulse voltammetric simultaneous determination of noradrenalin and acetaminophen using a hematoxylin biosensor

被引:58
|
作者
Nasirizadeh, Navid [1 ]
Zare, Hamid R. [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd 89195741, Iran
关键词
Noradrenalin; Acetaminophen; Differential pulse voltammetry; Biosensor; Hematoxylin; GLASSY-CARBON ELECTRODE; ADENINE-DINUCLEOTIDE NADH; ASCORBIC-ACID; URIC-ACID; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; DERIVATIVE SPECTROPHOTOMETRY; PHARMACEUTICAL FORMULATIONS; ELECTROCHEMICAL PROPERTIES; MASS-SPECTROMETRY;
D O I
10.1016/j.talanta.2009.07.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L-1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, alpha, the catalytic electron transfer rate constant, k', and the standard catalytic electron transfer rate constant, k(0), for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 x 10(-1) to 65.40 mu mol L-1 and 65.40-274.20 mu mol L-1 of NA, and for 12.00-59.10 mu mol L-1 and 59.10-261.70 mu mol L-1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 +/- 0.03 mu A for an electrolyte solution containing 5.00 mu mol L-1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:656 / 663
页数:8
相关论文
共 50 条
  • [1] Preparation and electrochemical application of rutin biosensor for differential pulse voltammetric determination of NADH in the presence of acetaminophen
    Zare, Hamid R.
    Samimi, Reza
    Nasirizadeh, Navid
    Mazloum-Ardakani, Mohammad
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2010, 75 (10) : 1421 - 1434
  • [2] Simultaneous determination of tyrosine, acetaminophen and ascorbic acid using gold nanoparticles/multiwalled carbon nanotube/glassy carbon electrode by differential pulse voltammetric method
    Madrakian, Tayyebeh
    Haghshenas, Esmaeel
    Afkhami, Abbas
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 451 - 460
  • [3] A New Sensitive Sensor for Simultaneous Differential Pulse Voltammetric Determination of Codeine and Acetaminophen Using a Hydroquinone Derivative and Multiwall Carbon Nanotubes Carbon Paste Electrode
    Garazhian, Elahe
    Shishehbore, M. Reza
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 2015
  • [4] Simultaneous voltammetric determination of droxidopa, acetaminophen, and tyrosine on hematoxylin and graphene oxide/ZnO nanocomposite-modified glassy carbon electrode
    Beitollahi, Hadi
    Salimi, Hadiseh
    Ganjali, Mohammad Reza
    IONICS, 2018, 24 (05) : 1487 - 1495
  • [5] Simultaneous voltammetric determination of droxidopa, acetaminophen, and tyrosine on hematoxylin and graphene oxide/ZnO nanocomposite-modified glassy carbon electrode
    Hadi Beitollahi
    Hadiseh Salimi
    Mohammad Reza Ganjali
    Ionics, 2018, 24 : 1487 - 1495
  • [6] Simultaneous FIA determination of two components with differential normal pulse voltammetric multidetection
    Alpizar, J
    Crespi, A
    Cladera, A
    Forteza, R
    Cerda, V
    ELECTROANALYSIS, 1997, 9 (03) : 247 - 250
  • [7] Voltammetric and differential pulse determination of roxithromycin
    Drljevic-Djuric, K. M.
    Jovic, V. D.
    Lacnjevac, U. C.
    Ivic, M. L. Avramov
    Petrovic, S. D.
    Mijin, D. Z.
    Djordjevic, S. B.
    ELECTROCHIMICA ACTA, 2010, 56 (01) : 47 - 52
  • [8] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF FAMOTIDINE
    SQUELLA, JA
    RIVERA, C
    LEMUS, I
    NUNEZVERGARA, LJ
    MIKROCHIMICA ACTA, 1990, 1 (5-6) : 343 - 348
  • [9] Differential pulse voltammetric simultaneous determination of four anti-inflammatory drugs by using soft modelling
    Reguera, C
    Ortiz, MC
    Arcos, MJ
    ELECTROANALYSIS, 2002, 14 (24) : 1699 - 1706
  • [10] Differential pulse voltammetric simultaneous determination of acetaminophen and ascorbic acid using single-walled carbon nanotube-modified carbon-ceramic electrode
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    Pournaghi-Azar, Mohammad Hossein
    ANALYTICAL BIOCHEMISTRY, 2011, 411 (02) : 167 - 175