Comparative evaluation of BacT/ALERT 3D and BACTEC systems for the recovery of pathogens causing bloodstream infections

被引:22
|
作者
Jamal, Wafaa [1 ]
Tamaray, Gigette [1 ]
Pazhoor, Aleyamma [1 ]
Rotimi, V. O. [1 ]
机构
[1] Mubarak Al Kabeer Hosp, Dept Lab Med, Microbiol Unit, Jabriya, Kuwait
关键词
BacT/ALERT blood culture system; BACTEC 9240 blood culture system; bacteraemia;
D O I
10.1159/000092186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare BacT/ALERT (BTA) and BACTEC 9240 (BAC), two continuously monitoring automated blood culture systems, for the recovery of bloodstream pathogens and standard media available for these systems. Materials and Methods: Blood samples from 100 adults and 50 paediatric patients suspected of having bloodstream infections were inoculated at the bedside into non-vented BTA and BAC standard blood culture bottles and incubated in their respective instruments. The time to growth detection (TD) was recorded for each bottle that became positive. A quantitative assay was also carried out with 5 standard bloodstream pathogens to assess TD of each pathogen as well as the quantity of organisms recovered. Results: A total of 23 isolates representing true infections were recovered by both BTA and BAC bottles, indicating a blood culture positivity rate of 15.3%, 18 (78.3%) by BTA bottles and 13 (56.5%) by BAC. Proteus mirabilis, Pseudomonas aeruginosa and Clostridium perfringens were recovered only by the BTA system. The average TDs were 19.0 and 24.6 h for BTA and BAC, respectively. Analysis of the quantitative growth of known pathogens in both systems was more or less the same for Staphylococcus aureus, Escherichia coli and P. aeruginosa but slightly different for Haemophilus influenzae and Streptococcus pneumoniae. The anaerobic bottle of the BTA did not support the growth of H. influenzae below an inoculum of 10(10) CFU/ml whereas the BAC did so at a lower inoculum of 10(8) CFU/ml. TD for S. pneumoniae in the BTA was about half of that in the BAC. Conclusions: The BTA system appears to be more efficient in detecting common bloodstream pathogens as a higher inoculum is needed for the BAC system to detect the same organism. Copyright (C) 2006 S. Karger AG, Basel.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [1] Comparative evaluation of BacT/ALERT VIRTUO and BACTEC FX400 blood culture systems for the detection of bloodstream infections
    Qin, Yurong
    Liao, Yiwen
    Zhou, Jingfang
    Liu, Weijiang
    Chen, Huimin
    Chen, Xiaoli
    Wang, Weisha
    Zhang, Ni
    Zhao, Yunhu
    Wang, Liang
    Gu, Bing
    Liu, Suling
    MICROBIOLOGY SPECTRUM, 2025, 13 (01)
  • [2] Comparative evaluation of BACTEC FX, BacT/ALERT 3D, and BacT/ALERT VIRTUO-automated blood culture systems using simulated blood cultures
    Li, Zhengkang
    Liu, Suling
    Chen, Huimin
    Zhang, Xinqiang
    Ling, Yong
    Zhang, Ni
    Hou, Tieying
    ACTA CLINICA BELGICA, 2022, 77 (01) : 71 - 78
  • [3] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Lilian
    Posteraro, Brunella
    Sabatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [4] Epidemiology of bloodstream infections and time to detection of positive blood cultures: An evaluation of the automated BacT/Alert and BACTEC 9240 systems
    Endimiani, A
    Tamborini, A
    Luzzaro, F
    Lombardi, G
    Toniolo, A
    MICROBIOLOGICA, 2002, 25 (01): : 9 - 16
  • [5] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples (vol 10, 221, 2019)
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Liliana
    Posteraro, Brunella
    Sabbatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [6] Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for Candida growth detection
    Horvath, LL
    George, BJ
    Murray, CK
    Harrison, LS
    Hospenthal, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 115 - 118
  • [7] Evaluation of the BacT/ALERT 3D system for recovery and drug susceptibility testing of Mycobacterium tuberculosis
    Ängeby, KAK
    Werngren, J
    Toro, JC
    Hedström, G
    Petrini, B
    Hoffner, SE
    CLINICAL MICROBIOLOGY AND INFECTION, 2003, 9 (11) : 1148 - 1152
  • [8] Comparison of Clinical Performance Between BacT/Alert Virtuo and BacT/Alert 3D Blood Culture Systems
    Kim, Seong Chun
    Lee, Seungjun
    Kim, Sunjoo
    Cho, Oh-Hyun
    Park, Hyunwoong
    Yu, Seong-Mi
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (03) : 237 - 242
  • [9] Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/ALERT 3D) on culture positivity
    Akan, ÖA
    Yildiz, E
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2006, 54 (03) : 193 - 196
  • [10] Platelet Bacterial Detection Experience with BACT/ALERT VIRTUO versus BACT/ALERT 3D
    Vassallo, R.
    Castro, K.
    James, J.
    Sanchez, J.
    Tysarczyk, M.
    TRANSFUSION, 2023, 63 : 216A - 217A