Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study

被引:11
|
作者
Min, Chang-Ki [1 ,2 ]
Kim, Kyoung-A [1 ,2 ]
机构
[1] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju, South Korea
[2] Jeonbuk Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Backjedaero 567, Jeonju, South Korea
关键词
Diagnostic Imaging; Cone-beam Computed Tomography; Artefacts; Dental implant; CONE-BEAM CT; COMPUTED-TOMOGRAPHY; FILLING MATERIALS; REDUCTION; MOTION; RANGE; JAW;
D O I
10.1259/dmfr.20200365
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject. Methods: Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (Tb-Th), trabecular spacing (Th-Sp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger's Z test. Results: Without the implants, in VOI1, the Spearman correlation coefficients of Tb-Th, Tb-Sp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90 degrees, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased. Conclusions: Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] A micro-investigation of unsaturated sand in mini-triaxial compression based on micro-CT image analysis
    Wang, Ji-Peng
    Luan, Ji-Yuan
    Gao, Xu-Guang
    Liu, Tai-Heng
    Ando, Edward
    Francois, Bertrand
    ACTA GEOTECHNICA, 2022, 17 (11) : 4799 - 4821
  • [42] CBCT and Micro-CT analysis of the mandibular first premolars with C-shaped canal system in a Chinese population author
    Zhang, Yimeng
    Weng, Xunben
    Fu, Yu
    Qi, Xuekai
    Pan, Yihuai
    Zhao, Yu
    BMC ORAL HEALTH, 2023, 23 (01)
  • [43] CBCT and Micro-CT analysis of the mandibular first premolars with C-shaped canal system in a Chinese population author
    Yimeng Zhang
    Xunben Weng
    Yu Fu
    Xuekai Qi
    Yihuai Pan
    Yu Zhao
    BMC Oral Health, 23
  • [44] Semi-Automatic Evaluation of Fetal Rabbit Skull Bones by Micro-CT Image Analysis
    Wise, L. D.
    Dogsas, B.
    Winkelmann, C. T.
    Pais, H.
    BIRTH DEFECTS RESEARCH PART A-CLINICAL AND MOLECULAR TERATOLOGY, 2011, 91 (05) : 371 - 371
  • [45] Digital Image Correlation Validation of Finite Element Strain Analysis of Dental Implant Insertion for Two Implant Designs
    Yang, Baixuan
    Irastorza-Landa, Ainara
    Heuberger, Peter
    Ploeg, Heidi-Lynn
    PROCEEDINGS OF ASME 2023 VERIFICATION, VALIDATION, AND UNCERTAINTY QUANTIFICATION SYMPOSIUM, VVUQ2023, 2023,
  • [46] Inside the kink-bands of archaeological flax artefacts via sub-micrometer resolution micro-CT: A comprehensive microstructural analysis to better understand degradation mechanisms of fibres
    Morgillo, Loren
    Melelli, Alessia
    Scheel, Mario
    Wightman, Raymond
    Weitkamp, Timm
    Goudenhooft, Camille
    Quiles, Anita
    Shah, Darshil U.
    Abida, Marwa
    Beaugrand, Johnny
    Bourmaud, Alain
    COMPOSITES PART B-ENGINEERING, 2025, 298
  • [47] The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study
    Mikic, Mirko
    Vlahovic, Zoran
    Nenezic, Dragoslav
    Videnovic, Goran
    Ilic, Danijela
    Mladenovic, Rasa
    VOJNOSANITETSKI PREGLED, 2021, 78 (08) : 811 - 817
  • [48] SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study
    Vinhas, Ana Sofia
    Salazar, Filomena
    Mendes, Jose Manuel
    Silva, Antonio Sergio
    Rios-Carrasco, Blanca
    Rios-Santos, Jose Vicente
    Gil, Javier
    Herrero-Climent, Mariano
    Aroso, Carlos
    MATERIALS, 2024, 17 (02)
  • [49] Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT
    Van Dessel, Jeroen
    Nicolielo, Laura Ferreira Pinheiro
    Huang, Yan
    Coudyzer, Walter
    Salmon, Benjamin
    Lambrichts, Ivo
    Jacobs, Reinhilde
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 95 - 105
  • [50] Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis
    Moris, Izabela C. M.
    Monteiro, Silas Borges
    Martins, Raissa
    Ribeiro, Ricardo Faria
    Gomes, Erica A.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018