Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study

被引:11
|
作者
Min, Chang-Ki [1 ,2 ]
Kim, Kyoung-A [1 ,2 ]
机构
[1] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju, South Korea
[2] Jeonbuk Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Backjedaero 567, Jeonju, South Korea
关键词
Diagnostic Imaging; Cone-beam Computed Tomography; Artefacts; Dental implant; CONE-BEAM CT; COMPUTED-TOMOGRAPHY; FILLING MATERIALS; REDUCTION; MOTION; RANGE; JAW;
D O I
10.1259/dmfr.20200365
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject. Methods: Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (Tb-Th), trabecular spacing (Th-Sp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger's Z test. Results: Without the implants, in VOI1, the Spearman correlation coefficients of Tb-Th, Tb-Sp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90 degrees, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased. Conclusions: Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Constant Strain Rate and Peri-Implant Bone Modeling: An In Vivo Longitudinal Micro-CT Analysis
    De Smet, Els
    Jaecques, Siegfried V. N.
    Wevers, Martine
    Vander Sloten, Jos
    Naert, Ignace E.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 358 - 366
  • [32] Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT
    Nakashima, Daisuke
    Ishii, Ken
    Nishiwaki, Yuji
    Kawana, Hiromasa
    Jinzaki, Masahiro
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01) : 1
  • [33] Quantitative analysis of vascular parameters for micro-CT imaging of vascular networks with multi-resolution
    Fengjun Zhao
    Jimin Liang
    Xueli Chen
    Junting Liu
    Dongmei Chen
    Xiang Yang
    Jie Tian
    Medical & Biological Engineering & Computing, 2016, 54 : 511 - 524
  • [34] Accurate segmentation for quantitative analysis of vascular trees in 3D micro-CT images
    Riedel, CH
    Chuah, SC
    Zamir, M
    Ritman, EL
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 256 - 265
  • [35] 3-D visual analysis and quantitative characterization on coal matrix based on Micro-CT
    Zhao, Changxin
    Cheng, Yuanping
    Wang, Chenghao
    Zhang, Kaizhong
    Wang, Zhenyang
    Chu, Peng
    Yang, Tao
    INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES, 2024, 176
  • [36] Quantitative analysis of vascular parameters for micro-CT imaging of vascular networks with multi-resolution
    Zhao, Fengjun
    Liang, Jimin
    Chen, Xueli
    Liu, Junting
    Chen, Dongmei
    Yang, Xiang
    Tian, Jie
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (2-3) : 511 - 524
  • [37] Quantitative CT-based bone strength parameters for the prediction of novel spinal implant stability using resonance frequency analysis: a cadaveric study involving experimental micro-CT and clinical multislice CT
    Daisuke Nakashima
    Ken Ishii
    Yuji Nishiwaki
    Hiromasa Kawana
    Masahiro Jinzaki
    Morio Matsumoto
    Masaya Nakamura
    Takeo Nagura
    European Radiology Experimental, 3
  • [38] Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning
    Li, Jun Yuan
    Pow, Edmond Ho Nang
    Zheng, Li Wu
    Ma, Li
    Kwong, Dora Lai Wan
    Cheung, Lim Kwong
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 506 - 510
  • [39] Quantitative Analysis of the Accuracy of CT to CBCT Deformable Image Registration for Contour Mapping for Prostate Cancer
    Schmidt, R.
    Dogan, N.
    Ford, J.
    Studenski, M.
    Abramowitz, M.
    Padgett, K.
    Spieler, B.
    Xu, Y.
    Delgadillo, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] A micro-investigation of unsaturated sand in mini-triaxial compression based on micro-CT image analysis
    Ji-Peng Wang
    Ji-Yuan Luan
    Xu-Guang Gao
    Tai-Heng Liu
    Edward Andò
    Bertrand François
    Acta Geotechnica, 2022, 17 : 4799 - 4821