Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study

被引:11
|
作者
Min, Chang-Ki [1 ,2 ]
Kim, Kyoung-A [1 ,2 ]
机构
[1] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju, South Korea
[2] Jeonbuk Natl Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Backjedaero 567, Jeonju, South Korea
关键词
Diagnostic Imaging; Cone-beam Computed Tomography; Artefacts; Dental implant; CONE-BEAM CT; COMPUTED-TOMOGRAPHY; FILLING MATERIALS; REDUCTION; MOTION; RANGE; JAW;
D O I
10.1259/dmfr.20200365
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Quantification of dental implant metal artefacts in CBCT images using correlation analysis of trabecular microstructural parameters from CBCT and micro-CT, and analysis of the effect of varying the angular position of the subject. Methods: Polyurethane synthetic bone blocks were first scanned without implants by micro-CT and CBCT. Two dental implants were then placed parallel in the bone blocks and these specimens were scanned by CBCT with different alpha angles. Three volumes of interest (VOI) were set for further analysis. Six microstructural parameters were measured: trabecular thickness (Tb-Th), trabecular spacing (Th-Sp), bone volume per total volume (BV/TV), bone surface per total volume (BS/TV), connectivity density (CD) andfractal dimension (FD). Micro-CT measurements were used as a gold standard for CBCT. Spearman correlation coefficients for each microstructural parameter from CBCT and micro-CT were calculated and compared using Steiger's Z test. Results: Without the implants, in VOI1, the Spearman correlation coefficients of Tb-Th, Tb-Sp, BV/TV, BS/TV, CD and FD were 0.599, 0.76, 0.552, 0.566, 0.664 and 0.607, respectively. With the implants, the correlation coefficients decreased sharply in VOI1. As the alpha angle increased from zero to 90 degrees, the correlation coefficients increased and became significant. Similar results appeared in VOI2. In contrast, in VOI3, the correlation coefficient decreased as the alpha angle increased. Conclusions: Metal artefacts were successfully quantified using microstructural parameters in terms of the image quality of the CBCT. Changes in alpha angle affected the quality of the CBCT image.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Microstructural Evaluation of Dental Implant Success Using Micro-CT: A Comprehensive Review
    Setiawan, Krisnadi
    Primarti, Risti Saptarini
    Sitam, Suhardjo
    Suridwan, Wawan
    Usri, Kosterman
    Latief, Fourier Dzar Eljabbar
    APPLIED SCIENCES-BASEL, 2024, 14 (23):
  • [2] Porosity Analysis in Metal Additive Manufacturing by Micro-CT
    Shrestha, Subin
    Starr, Thomas
    Chou, Kevin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 2, 2019,
  • [3] Qualitative and Quantitative Micro-CT Analysis of Natal and Neonatal Teeth
    Bijle, Mohammed Nadeem
    Mallineni, Sreekanth Kumar
    Tsoi, James
    CHILDREN-BASEL, 2022, 9 (04):
  • [4] QUANTITATIVE MICRO-CT ANALYSIS OF BONE IN ZEBRAFISH FOR STUDIES OF OA
    Russell, R.
    Tsang, K.
    Harris, M.
    Aliprantis, A.
    Charles, J.
    Duryea, J.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 : A205 - A206
  • [5] A comparative study of new and current methods for dental micro-CT image denoising
    Shahmoradi, Mahdi
    Lashgari, Mojtaba
    Rabbani, Hossein
    Qin, Jie
    Swain, Michael
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (03)
  • [6] Micro-CT Analysis of Microgap at a Novel Two-Piece Dental Implant Comprising a Replaceable Sleeve In Vitro
    Kapishnikov, Sergey
    Gadyukov, Adir
    Chaushu, Gavriel
    Chaushu, Liat
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 451 - 459
  • [7] Micro-CT Structure Analysis on Dental Implants: Preliminary In Vitro Trial
    Galletti, Fulvia
    D'Angelo, Tommaso
    Fiorillo, Luca
    Lo Giudice, Paola
    Irrera, Natasha
    Rizzo, Giuseppina
    Cervino, Gabriele
    PROSTHESIS, 2024, 6 (06): : 1437 - 1447
  • [8] Osseointegration of titanium dental implant under fluoride exposure in rabbits: Micro-CT and histomorphometry study
    Yu, Ying-juan
    Zhu, Wen-qing
    Xu, Li-na
    Ming, Pan-pan
    Shao, Shui-yi
    Qiu, Jing
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (10) : 1038 - 1048
  • [9] Quantitative topographic anatomy of the femoral ACL footprint: a micro-CT analysis
    Norman, Daniel G.
    Getgood, Alan
    Thornby, John
    Bird, Jonathan
    Turley, Glen A.
    Spalding, Tim
    Williams, Mark A.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (11) : 985 - 995
  • [10] Quantitative topographic anatomy of the femoral ACL footprint: a micro-CT analysis
    Daniel G. Norman
    Alan Getgood
    John Thornby
    Jonathan Bird
    Glen A. Turley
    Tim Spalding
    Mark A. Williams
    Medical & Biological Engineering & Computing, 2014, 52 : 985 - 995