Early Results of Descemet-Stripping and Automated Endothelial Keratoplasty (DSAEK) in Patients With Glaucoma Drainage Devices

被引:37
|
作者
Riaz, Kamran M. [1 ]
Sugar, Joel [1 ]
Tu, Elmer Y. [1 ]
Edward, Deepak P. [1 ]
Wilensky, Jacob T. [1 ]
Namavari, Abed [1 ]
Djalilian, Ali R. [1 ]
机构
[1] Univ Illinois, Chicago Eye & Ear Infirmary, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
关键词
DSAEK; tube shunt; air bubble; PENETRATING KERATOPLASTY; PRECUT TISSUE; DISLOCATION;
D O I
10.1097/ICO.0b013e31819c4e2c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the outcome of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma tube shunts in the anterior chamber. Methods: Retrospective review of 4 patients with a history Of tube shunt placement that experienced corneal decompensation and subsequently underwent DSAEK at 1 institution. Details of the Surgical procedures as well as postoperative features including graft attachment, visual acuity, intraocular pressure (IOP), graft clarity, and central corneal thickness were recorded. Results: There were no graft detachments postoperatively. In all but 1 case, the corneal edema resolved with a corresponding decrease in corneal thickness. In 1 case, where there was excessive donor tissue manipulation intraoperatively, the edema failed to resolve. This patient underwent a repeat DSAEK with subsequent graft attachment and resolution of the corneal edema. In all 4 patients, the tube Shunt was revised at the time of DSAEK. The tube was not tied or plugged in any of the patients. Except for 1 patient with fibrin reaction, there were no IOP spikes postoperatively. At the 6-month follow-up, the visual acuity had improved in all patients and the IOP had not changed significantly front preoperative levels. Conclusion: This small series suggests that DSAEK is a viable and effective option in patients with existing tube shunts. The presence of a tube did not affect the rate of graft dislocation; however, it appeared to increased the rate of complications postoperatively. These early outcomes support the use of DSAEK as an alternative to penetrating keratoplasty in this patient population.
引用
收藏
页码:959 / 962
页数:4
相关论文
共 50 条
  • [41] Posteriore lamelläre Keratoplastik (DSAEK)Descemet’s stripping automated endothelial keratoplasty (DSAEK)
    C. Cursiefen
    F.E. Kruse
    Der Ophthalmologe, 2009, 106 : 939 - 954
  • [42] Subconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Ide, Takeshi
    Kymionis, George D.
    Yoo, Sonia H.
    O'Brien, Terrence P.
    OPEN OPHTHALMOLOGY JOURNAL, 2008, 2 : 107 - 108
  • [43] Immunreaktion mit Khodadoust-Linie nach ‚‚Descemet stripping automated endothelial keratoplasty’‘ (DSAEK)Immunological graft rejection with Khodadoust line after “Descemet stripping automated endothelial keratoplasty” (DSAEK)
    M. Fiorentzis
    A. Viestenz
    B. Seitz
    Der Ophthalmologe, 2015, 112 : 783 - 787
  • [44] Comparison of the Visual Outcomes of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) and Penetrating Keratoplasty
    Chikama, T. -I.
    Sato, Y.
    Morita, Y.
    Yanai, R.
    Yamada, N.
    Morishige, N.
    Nishida, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [45] Visual Outcomes in Phakic Patients Undergoing Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Tsui, J. Y.
    Wagoner, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Visual quality assessment after DSAEK corneal keratoplasty (Descemet Stripping Automated Endothelial Keratoplasty)
    Guechi, Oualid
    Boiche, Mathilde
    Yahia, Rekia
    Ghetemme, Cedric
    Houmad, Naila
    Baudot, Audrey
    Ameloot, Francois
    Perone, Jean-Marc
    Bertaux, Pierre-jean
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [47] Spontaneous Reattachment of a Detached Sutured Descemet-Stripping Automated Endothelial Keratoplasty Graft
    Gad, Rania E.
    Kahn, Jonathan
    Trief, Danielle
    CASE REPORTS IN OPHTHALMOLOGY, 2024, 15 (01): : 41 - 46
  • [48] Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) vs Ultra-Thin DSAEK (UT-DSAEK) vs Descemet's Membrane Endothelial Keratoplasty (DMEK)
    Yan, Peng
    Teja, Salina
    Baig, Kashif
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [49] Retained nuclear fragment found during Descemet-stripping automated endothelial keratoplasty
    Mifflin, Mark D.
    Neuffer, Marcus C.
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03): : 608 - 610
  • [50] Outcome of Descemet Stripping Endothelial Keratoplasty (DSAEK) in Patients with Previous Trabeculectomy
    Morita, Yukiko
    Morishige, Naoyuki
    Yamada, Naoyuki
    Okamura, Nanako
    Ohta, Manami
    Teranishi, Shin-Ichiro
    Suzuki, Katsuyoshi
    Sonoda, Koh-hei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)