Early Results of Descemet-Stripping and Automated Endothelial Keratoplasty (DSAEK) in Patients With Glaucoma Drainage Devices

被引:37
|
作者
Riaz, Kamran M. [1 ]
Sugar, Joel [1 ]
Tu, Elmer Y. [1 ]
Edward, Deepak P. [1 ]
Wilensky, Jacob T. [1 ]
Namavari, Abed [1 ]
Djalilian, Ali R. [1 ]
机构
[1] Univ Illinois, Chicago Eye & Ear Infirmary, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
关键词
DSAEK; tube shunt; air bubble; PENETRATING KERATOPLASTY; PRECUT TISSUE; DISLOCATION;
D O I
10.1097/ICO.0b013e31819c4e2c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the outcome of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma tube shunts in the anterior chamber. Methods: Retrospective review of 4 patients with a history Of tube shunt placement that experienced corneal decompensation and subsequently underwent DSAEK at 1 institution. Details of the Surgical procedures as well as postoperative features including graft attachment, visual acuity, intraocular pressure (IOP), graft clarity, and central corneal thickness were recorded. Results: There were no graft detachments postoperatively. In all but 1 case, the corneal edema resolved with a corresponding decrease in corneal thickness. In 1 case, where there was excessive donor tissue manipulation intraoperatively, the edema failed to resolve. This patient underwent a repeat DSAEK with subsequent graft attachment and resolution of the corneal edema. In all 4 patients, the tube Shunt was revised at the time of DSAEK. The tube was not tied or plugged in any of the patients. Except for 1 patient with fibrin reaction, there were no IOP spikes postoperatively. At the 6-month follow-up, the visual acuity had improved in all patients and the IOP had not changed significantly front preoperative levels. Conclusion: This small series suggests that DSAEK is a viable and effective option in patients with existing tube shunts. The presence of a tube did not affect the rate of graft dislocation; however, it appeared to increased the rate of complications postoperatively. These early outcomes support the use of DSAEK as an alternative to penetrating keratoplasty in this patient population.
引用
收藏
页码:959 / 962
页数:4
相关论文
共 50 条
  • [31] Descemet-stripping Automated Endothelial Keratoplasty by Using Suture for Donor Insertion
    Sarnicola, Vincenzo
    Toro, Patricia
    CORNEA, 2008, 27 (07) : 825 - 829
  • [32] Ischemic optic neuropathy after Descemet-stripping automated endothelial keratoplasty
    Rosenberg, Christopher R.
    Weissbart, Sarah B.
    Sibony, Patrick A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : E8 - E10
  • [33] Modification in Descemet-stripping automated endothelial keratoplasty - "Hitch suture" technique
    Vajpayee, Rasik B.
    Agarwal, Tushar
    Jhanji, Vishal
    Sharma, Namrata
    CORNEA, 2006, 25 (09) : 1060 - 1062
  • [34] Descemet-stripping automated endothelial keratoplasty after bee sting of the cornea
    Hammel, Na'ama
    Bahar, Irit
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09): : 1726 - 1728
  • [35] Failed Descemet-Stripping Automated Endothelial Keratoplasty Grafts: A Clinicopathologic Analysis
    Shulman, Julia
    Kropinak, Mark
    Ritterband, David C.
    Perry, Henry D.
    Seedor, John A.
    McCormick, Steven A.
    Milman, Tatyana
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (05) : 752 - 759
  • [36] Outcomes of Descemet-Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy
    Mohebbi, Masoomeh
    Nabavi, Amin
    Fadakar, Kaveh
    Hashemi, Hassan
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 57 - 62
  • [37] Textural interface opacity after Descemet-stripping automated endothelial keratoplasty
    Kim, Keunsoo
    Alder, Brian
    Vora, Gargi K.
    Carlson, Alan N.
    Afshari, Natalie A.
    Kuo, Anthony N.
    Kim, Terry
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (09): : 1514 - 1520
  • [38] Modified Descemet’s stripping automated endothelial keratoplasty for eyes with glaucoma drainage devices and shallow anterior chambers
    Alfonso Vasquez-Perez
    Syed Mohammed Naqib
    Mayank A. Nanavaty
    International Ophthalmology, 2018, 38 : 1753 - 1757
  • [39] Modified Descemet's stripping automated endothelial keratoplasty for eyes with glaucoma drainage devices and shallow anterior chambers
    Vasquez-Perez, Alfonso
    Naqib, Syed Mohammed
    Nanavaty, Mayank A.
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1753 - 1757
  • [40] Posteriore lamelläre Keratoplastik (DSAEK)Descemet’s stripping with automated endothelial keratoplasty (DSAEK)
    C. Cursiefen
    F.E. Kruse
    Der Ophthalmologe, 2008, 105 : 183 - 192