Early Results of Descemet-Stripping and Automated Endothelial Keratoplasty (DSAEK) in Patients With Glaucoma Drainage Devices

被引:37
|
作者
Riaz, Kamran M. [1 ]
Sugar, Joel [1 ]
Tu, Elmer Y. [1 ]
Edward, Deepak P. [1 ]
Wilensky, Jacob T. [1 ]
Namavari, Abed [1 ]
Djalilian, Ali R. [1 ]
机构
[1] Univ Illinois, Chicago Eye & Ear Infirmary, Dept Ophthalmol & Visual Sci, Chicago, IL 60612 USA
关键词
DSAEK; tube shunt; air bubble; PENETRATING KERATOPLASTY; PRECUT TISSUE; DISLOCATION;
D O I
10.1097/ICO.0b013e31819c4e2c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the outcome of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma tube shunts in the anterior chamber. Methods: Retrospective review of 4 patients with a history Of tube shunt placement that experienced corneal decompensation and subsequently underwent DSAEK at 1 institution. Details of the Surgical procedures as well as postoperative features including graft attachment, visual acuity, intraocular pressure (IOP), graft clarity, and central corneal thickness were recorded. Results: There were no graft detachments postoperatively. In all but 1 case, the corneal edema resolved with a corresponding decrease in corneal thickness. In 1 case, where there was excessive donor tissue manipulation intraoperatively, the edema failed to resolve. This patient underwent a repeat DSAEK with subsequent graft attachment and resolution of the corneal edema. In all 4 patients, the tube Shunt was revised at the time of DSAEK. The tube was not tied or plugged in any of the patients. Except for 1 patient with fibrin reaction, there were no IOP spikes postoperatively. At the 6-month follow-up, the visual acuity had improved in all patients and the IOP had not changed significantly front preoperative levels. Conclusion: This small series suggests that DSAEK is a viable and effective option in patients with existing tube shunts. The presence of a tube did not affect the rate of graft dislocation; however, it appeared to increased the rate of complications postoperatively. These early outcomes support the use of DSAEK as an alternative to penetrating keratoplasty in this patient population.
引用
收藏
页码:959 / 962
页数:4
相关论文
共 50 条
  • [21] Descemet-stripping automated endothelial keratoplasty with a donor tissue injector
    Khor, Wei-Boon
    Kim, Terry
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1768 - 1772
  • [22] Guttae in the donor after Descemet-stripping automated endothelial keratoplasty
    Lee, Bryan S.
    Virdi, Ajoy S.
    Hammersmith, Kristin M.
    Jun, Albert S.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (10) : 1523 - 1525
  • [23] Guttae in the donor after Descemet-stripping automated endothelial keratoplasty
    Bryan S. Lee
    Ajoy S. Virdi
    Kristin M. Hammersmith
    Albert S. Jun
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 1523 - 1525
  • [24] Clinical Outcomes of Descemet Stripping Endothelial Keratoplasty in Eyes With Glaucoma Drainage Devices
    Mansoori, Tarannum
    Srirampur, Arjun
    Balijepalli, Pasyanthi
    JOURNAL OF GLAUCOMA, 2019, 28 (11) : E169 - E169
  • [25] Clinical Outcomes of Descemet Stripping Endothelial Keratoplasty in Eyes With Glaucoma Drainage Devices
    Kang, Joann J.
    Ritterband, David C.
    Atallah, Richard T.
    Liebmann, Jeffrey M.
    Seedor, John A.
    JOURNAL OF GLAUCOMA, 2019, 28 (07) : 601 - 605
  • [26] Descemet-stripping automated endothelial keratoplasty: a successful alternative to repeat penetrating keratoplasty
    Lee, Bryan S.
    Stark, Walter J.
    Jun, Albert S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03): : 195 - 200
  • [27] Outcomes of Descemet Stripping Automated Endothelial Keratoplasty in Patients With Previous Glaucoma Drainage Device Insertion
    Kim, Peter
    Amiran, Maoz D.
    Lichtinger, Alejandro
    Yeung, Sonia N.
    Slomovic, Allan R.
    Rootman, David S.
    CORNEA, 2012, 31 (02) : 172 - 175
  • [28] Prevention and management of complications in Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK)
    Cursiefen, C.
    Steven, P.
    Roters, S.
    Heindl, L. M.
    OPHTHALMOLOGE, 2013, 110 (07): : 614 - +
  • [29] Descemet-stripping Automated Endothelial Keratoplasty Effect of Anterior Lamellar Corneal Tissue-On/-Off Storage Condition on Descemet-stripping Automated Endothelial Keratoplasty Donor Tissue
    Ide, Takeshi
    Yoo, Sonia H.
    Kymionis, George D.
    Goldman, James M.
    Perez, Victor L.
    O'Brien, Terrence P.
    CORNEA, 2008, 27 (07) : 754 - 757
  • [30] Descemet's stripping with automated endothelial keratoplasty and glaucoma
    Banitt, Michael R.
    Chopra, Vikas