Flow-injection chemiluminescence sensor for determination of isoniazid in urine sample based on molecularly imprinted polymer

被引:41
|
作者
Xiong, Yan [1 ]
Zhou, Houjiang [1 ]
Zhang, Zhujun [1 ]
He, Deyong [1 ]
He, Chao [1 ]
机构
[1] SW China Univ, Dept Chem, Inst Analyt Chem, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
isoniazid; molecularly imprinted polymer; chemiluminescence sensor;
D O I
10.1016/j.saa.2006.03.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, molecularly imprinted polymer (MIP) of isoniazid is synthesized through thermal radical copolymerization of metharylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) in the presence of isoniazid template molecules. A novel flow injection chemiluminescence sensor for isoniazid determination is developed by packing the isoniazid-MIP into the flow cell as recognition elements. Isoniazid could be selectively adsorbed by the MIPs and the adsorbed isoniazid was sensed by its great enhancing effect on the weak CL reaction between luminol and periodate which were mixed in the flow cell. The enhanced CL intensity is linear in the range 2 x 10(-9) to 2 x 10(-7) g/mL and the detection limit is 7 x 10(-10) g/mL (3 sigma) isoniazid with a relative standard deviation 2.8% (n =9) for 8 x 10(-8) g/mL. The sensor is reversible and reusable. It has a great improvement in sensitivity and selectivity for CL analysis. As a result, the sensor has been successfully applied to determination of isoniazid in human urine. At the same time, the binding characteristic of the polymer to isoniazid was evaluated by batch method and the dynamic method, respectively. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 50 条
  • [21] Flow-Injection Preconcentration of Chloramphenicol Using Molecularly Imprinted Polymer for HPLC Determination in Environmental Samples
    Kowalski, Damian
    Pobozy, Ewa
    Trojanowicz, Marek
    JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2011,
  • [22] Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline
    Xiong, Yan
    Zhou, Houjiang
    Zhang, Zhujun
    He, Deyong
    He, Chao
    ANALYST, 2006, 131 (07) : 829 - 834
  • [23] Flow injection chemiluminescence sensor using molecularly imprinted polymers as recognition element for determination of maleic hydrazide
    Fang, Yanjun
    Yan, Shoulei
    Ning, Baoan
    Liu, Nan
    Gao, Zhixian
    Chao, Fuhuan
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2323 - 2327
  • [24] Flow-Injection Chemiluminescence Determination of Trace Copper On-Line Separation and Enrichment by Ion Imprinted Polymer
    Li Hui-zhi
    Pei Mei-shan
    Zhang Jin
    Wei Qin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (06) : 1472 - 1475
  • [25] Flow injection chemiluminescence sensor based on core-shell magnetic molecularly imprinted nanoparticles for determination of chrysoidine in food samples
    Lu, Fuguang
    Sun, Min
    Fan, Lulu
    Qiu, Huamin
    Li, Xiangjun
    Luo, Chuannan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 591 - 598
  • [26] Flow-injection Chemiluminescence Determination of Catecholamines
    Cheng Xiao ZHANG
    Zhu Jun ZHANG(Department of Chemistry
    (Lu’an Teacher’s College
    Chinese Chemical Letters, 1998, (09) : 843 - 845
  • [27] Flow-injection chemiluminescence determination of fluoroquinolones
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, GA
    Baeyens, WRG
    ANALYTICAL LETTERS, 2000, 33 (06) : 1117 - 1129
  • [28] Flow-injection chemiluminescence determination of catecholamines
    Wolyniec, Elzbieta
    Niedzwiedzka, Urszula
    Kojlo, Anatol
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (02) : 219 - 231
  • [29] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    ANALYST, 1987, 112 (06) : 883 - 886
  • [30] Flow-injection chemiluminescence determination of catecholamines
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 843 - 845