Flow-injection chemiluminescence sensor for determination of isoniazid in urine sample based on molecularly imprinted polymer

被引:41
|
作者
Xiong, Yan [1 ]
Zhou, Houjiang [1 ]
Zhang, Zhujun [1 ]
He, Deyong [1 ]
He, Chao [1 ]
机构
[1] SW China Univ, Dept Chem, Inst Analyt Chem, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
isoniazid; molecularly imprinted polymer; chemiluminescence sensor;
D O I
10.1016/j.saa.2006.03.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, molecularly imprinted polymer (MIP) of isoniazid is synthesized through thermal radical copolymerization of metharylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) in the presence of isoniazid template molecules. A novel flow injection chemiluminescence sensor for isoniazid determination is developed by packing the isoniazid-MIP into the flow cell as recognition elements. Isoniazid could be selectively adsorbed by the MIPs and the adsorbed isoniazid was sensed by its great enhancing effect on the weak CL reaction between luminol and periodate which were mixed in the flow cell. The enhanced CL intensity is linear in the range 2 x 10(-9) to 2 x 10(-7) g/mL and the detection limit is 7 x 10(-10) g/mL (3 sigma) isoniazid with a relative standard deviation 2.8% (n =9) for 8 x 10(-8) g/mL. The sensor is reversible and reusable. It has a great improvement in sensitivity and selectivity for CL analysis. As a result, the sensor has been successfully applied to determination of isoniazid in human urine. At the same time, the binding characteristic of the polymer to isoniazid was evaluated by batch method and the dynamic method, respectively. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 50 条
  • [31] Determination of norfloxacin by flow-injection chemiluminescence
    Liao, SL
    Xie, ZH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1938 - 1942
  • [32] Determination of sulfonamides in meat with dummy-template molecularly imprinted polymer-based chemiluminescence sensor
    Zhao Bin Li
    Jing Liu
    Ju Xiang Liu
    Zhan Hui Wang
    Jian Ping Wang
    Analytical and Bioanalytical Chemistry, 2019, 411 : 3179 - 3189
  • [33] Determination of sulfonamides in meat with dummy-template molecularly imprinted polymer-based chemiluminescence sensor
    Li, Zhao Bin
    Liu, Jing
    Liu, Ju Xiang
    Wang, Zhan Hui
    Wang, Jian Ping
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (14) : 3179 - 3189
  • [34] A flow-injection chemiluminescent biomimetic immunoassay method using a molecularly imprinted polymer as a biomimetic antibody for the determination of trichlorfon
    Wang, Shoumin
    Jiang, Mingdi
    Ju, Zeliang
    Qiao, Xuguang
    Xu, Zhixiang
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 159 - 170
  • [35] A flow injection chemiluminescence system for the determination of isoniazid
    Y. Huang
    Z. Zhang
    D. Zhang
    J. Lv
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 429 - 431
  • [36] A flow injection chemiluminescence system for the determination of isoniazid
    Huang, YM
    Zhang, ZJ
    Zhang, DJ
    Lv, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (04): : 429 - 431
  • [37] Molecularly imprinted polymer-based chemiluminescence array sensor for the detection of proline
    Chang, Pingping
    Zhang, Zhujun
    Yang, Chunyan
    ANALYTICA CHIMICA ACTA, 2010, 666 (1-2) : 70 - 75
  • [38] Flow injection fluorimetric determination of β-estradiol using a molecularly imprinted polymer
    Bravo, JC
    Fernández, P
    Durand, JS
    ANALYST, 2005, 130 (10) : 1404 - 1409
  • [39] Flow-injection Chemiluminescence Sensor for the Determination of Free Chlorine in Tap Water
    Shu Na LIU
    Wei QIN
    Zhu Jun ZHANGDepartment of Chemistry Shaanxi Normal University Xi an
    Chinese Chemical Letters, 1996, (11)
  • [40] Flow-injection determination of vitamin K3 by a chemiluminescence sensor
    Huang, YM
    Chen, ZQ
    Zhang, ZJ
    ANALYTICAL SCIENCES, 1999, 15 (12) : 1227 - 1230