Flow-injection chemiluminescence determination of fluoroquinolones

被引:47
|
作者
Rao, Y
Tong, Y
Zhang, XR [1 ]
Luo, GA
Baeyens, WRG
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] State Univ Ghent, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
ofloxacin; norfloxacin; ciprofloxacin; lomefloxacin; chemiluminescence; flow-injection; cerium (IV);
D O I
10.1080/00032710008543113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-injection CL method was developed for the determination of fluoroquinolones including ofloxacin, norfloxacin, ciprofloxacin and lomefloxacin in pharmaceutical preparations, based on the chemiluminescence reaction of sulphite with cerium(IV) sensitized by these compounds. The linear ranges are 0.04 to 4.0 mu g ml(-1) for ofloxacin and 0.4 to 40.0 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The detection limits are 0.016 mu g ml(-1) for ofloxacin and 0.16 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The relative standard deviations (RSD) are 2.1 to 2.6% (n = 10) for these fluoroquinolones. The analytical procedure has been applied to the determination of the fluoroquinolones in pharmaceutical commercial formulations. The results are in agreement with those obtained by the official methods.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 50 条
  • [1] Flow-injection chemiluminescence determination of fluoroquinolones by enhancement of weak chemiluminescence from peroxynitrous acid
    Liang, YD
    Song, JF
    Yang, XF
    [J]. ANALYTICA CHIMICA ACTA, 2004, 510 (01) : 21 - 28
  • [2] Flow-injection electrogenerated chemiluminescence determination of fluoroquinolones based on its sensitizing effect
    Ma, HY
    Zheng, XW
    Zhang, ZJ
    [J]. LUMINESCENCE, 2005, 20 (4-5) : 303 - 306
  • [3] Flow-injection Chemiluminescence Determination of Catecholamines
    Cheng Xiao ZHANG
    Zhu Jun ZHANG(Department of Chemistry
    (Lu’an Teacher’s College
    [J]. Chinese Chemical Letters, 1998, (09) : 843 - 845
  • [4] Flow-injection chemiluminescence determination of catecholamines
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    [J]. CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 843 - 845
  • [5] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    [J]. ANALYST, 1987, 112 (06) : 883 - 886
  • [6] Flow-injection chemiluminescence determination of catecholamines
    Wolyniec, Elzbieta
    Niedzwiedzka, Urszula
    Kojlo, Anatol
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (02) : 219 - 231
  • [7] Determination of norfloxacin by flow-injection chemiluminescence
    Liao, SL
    Xie, ZH
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1938 - 1942
  • [8] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [9] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    [J]. ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [10] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667