Flow-injection chemiluminescence determination of fluoroquinolones

被引:47
|
作者
Rao, Y
Tong, Y
Zhang, XR [1 ]
Luo, GA
Baeyens, WRG
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] State Univ Ghent, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
ofloxacin; norfloxacin; ciprofloxacin; lomefloxacin; chemiluminescence; flow-injection; cerium (IV);
D O I
10.1080/00032710008543113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-injection CL method was developed for the determination of fluoroquinolones including ofloxacin, norfloxacin, ciprofloxacin and lomefloxacin in pharmaceutical preparations, based on the chemiluminescence reaction of sulphite with cerium(IV) sensitized by these compounds. The linear ranges are 0.04 to 4.0 mu g ml(-1) for ofloxacin and 0.4 to 40.0 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The detection limits are 0.016 mu g ml(-1) for ofloxacin and 0.16 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The relative standard deviations (RSD) are 2.1 to 2.6% (n = 10) for these fluoroquinolones. The analytical procedure has been applied to the determination of the fluoroquinolones in pharmaceutical commercial formulations. The results are in agreement with those obtained by the official methods.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 50 条
  • [41] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (03) : 167 - 174
  • [42] Chemiluminescence flow-injection immunoassays
    Gübitz, G
    Schmid, MG
    Silviaeh, H
    Aboul-Enein, HY
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2001, 31 (02) : 141 - 148
  • [43] Flow-injection chemiluminescence and electrogenerated chemiluminescence determination of escitalopram oxalate in tablet form
    Alarfaj, Nawal A.
    Aly, Fatma A.
    Al-Qahtany, Abeer A.
    LUMINESCENCE, 2013, 28 (01) : 84 - 92
  • [44] Determination of phosphate in freshwater samples by flow-injection with lucigenin chemiluminescence
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    Khan, Maqsood A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (14-15) : 1119 - 1129
  • [45] FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION FOR DETERMINATION OF FREE-CHOLESTEROL
    HO, CN
    BISHOP, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 140 - ANYL
  • [46] Flow-Injection Post-Chemiluminescence Method for the Determination of Palmatine
    Han, Suqin
    Wei, Bei
    Hao, Fang
    APPLIED SPECTROSCOPY, 2013, 67 (07) : 747 - 751
  • [47] CHEMILUMINESCENCE DETERMINATION OF NITRATE WITH PHOTOCHEMICAL ACTIVATION IN A FLOW-INJECTION SYSTEM
    LIU, RM
    LIU, DJ
    SUN, AL
    LIU, GH
    TALANTA, 1995, 42 (03) : 437 - 440
  • [48] Determination of ozone in aqueous by flow-injection analysis with chemiluminescence detection
    Jin, BH
    He, Y
    Zhuang, ZX
    Wang, XR
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 580 - 583
  • [49] The determination of glutamine with flow-injection chemiluminescence detection and mechanism study
    Liu, Yan-Ming
    Liu, Zhuan-Li
    Shi, Yan-Mei
    Tian, Wei
    LUMINESCENCE, 2010, 25 (01) : 50 - 54
  • [50] Development of a New Flow-injection Chemiluminescence Method for the Determination of Sulfide
    Yang Yingchun
    Feng Yuanyuan
    Ye Zhixiang
    Yin Honglin
    Yang Huaijin
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,