Measurement and correction of misalignments in corneal topography using the null-screen method

被引:9
|
作者
Campos-Garcia, Manuel [1 ]
Aguirre-Aguirre, Daniel [1 ]
Ivan Moreno-Oliva, Victor [2 ]
Huerta-Carranza, Oliver [1 ]
de Emanuel Armengol-Cruz, Victor [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Apdo Postal 70-186, Mexico City 04510, DF, Mexico
[2] Univ Istmo, Ciudad Univ S-N, Tehuantepec 70760, Oax, Mexico
关键词
SURFACES;
D O I
10.1364/OSAC.409933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Misalignments are a common problem in corneal topography reconstruction. To determine the topography of the surface using a corneal topographer based on the null-screen method, it is necessary to measure errors caused by mechanical misalignment of the topographer, which could influence the results of this technique but are not related to the quality of the corneal surface. To evaluate the variability in measurements, in this work, we simulate some misalignments in the optical system, for the simulation we design a semi-radial null-screen to test a reference spherical surface to identify the variations in results introduced by misalignment errors of the corneal topographer with respect to the test surface. According to the simulations, the accuracy of the null-screen method ranges from 0.81 mu m to 2.84 mu m for typical tilt, decentering, and defocusing errors. Experimental results for the testing of a spherical surface are shown. After removing the misalignments, we found that the variations are approximately 3.5 mu m rms value measured with respect to the best-fitting sphere, and the radius of curvature differs approximately 0.06% from the design value. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:158 / 170
页数:13
相关论文
共 50 条
  • [41] Effectiveness of a Cranial Distortion Correction Software Using A Novel Measurement Method
    Belloeil-Marrane, T.
    Gutierrez, A.
    Smeulders, J.
    Gevaert, T.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1406 - S1407
  • [42] Roughness correction method for the measurement of attenuation coefficient using contact transducers
    Fu, Tong
    Chen, Ping
    Liu, Huaqiang
    INSIGHT, 2022, 64 (10) : 582 - 588
  • [43] Elevation angle measurement for low-angle targets using synthesized pattern null method
    Wu, Suxing
    Shen, Lei
    Geng, Liang
    Yang, Guang
    Zhang, Pengda
    Zhang, Yanran
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (08) : 2217 - 2223
  • [44] Quantitative temperature measurement of an electrically heated carbon nanotube using the null-point method
    Chung, Jaehun
    Kim, Kyeongtae
    Hwang, Gwangseok
    Kwon, Ohmyoung
    Jung, Seungwon
    Lee, Junghoon
    Lee, Jae Woo
    Kim, Gyu Tae
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (11):
  • [45] Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method
    Hannink, Erin
    Dawes, Helen
    Shannon, Thomas M. L.
    Barker, Karen L.
    SPINE DEFORMITY, 2022, 10 (06) : 1299 - 1306
  • [46] AUTOMATIC TREE DATA REMOVAL METHOD FOR TOPOGRAPHY MEASUREMENT RESULT USING TERRESTRIAL LASER SCANNER
    Yokoyama, Hiroshi
    Chikatsu, Hirofumi
    3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2017, 42-2 (W3): : 659 - 664
  • [47] Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method
    Erin Hannink
    Helen Dawes
    Thomas M. L. Shannon
    Karen L. Barker
    Spine Deformity, 2022, 10 : 1299 - 1306
  • [48] Covariate Measurement Error Correction for Student Growth Percentiles Using the SIMEX Method
    Shang, Yi
    VanIwaarden, Adam
    Betebenner, Damian W.
    EDUCATIONAL MEASUREMENT-ISSUES AND PRACTICE, 2015, 34 (01) : 4 - 14
  • [49] Local measurement of weak stresses on the surface of HgCdTe/CdTe/ZnTe/GaAs structures using the null method
    Stupak, M. F.
    Dvoretsky, S. A.
    Mikhailov, N. N.
    Makarov, S. N.
    Elesin, A. G.
    JOURNAL OF APPLIED PHYSICS, 2023, 134 (18)
  • [50] Topography-based flying-spot-mode correction of irregular corneal astigmatism using the 193NM excimer laser.
    Seitz, B
    Langenbucher, A
    Kus, MM
    Naumann, GOH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2494 - 2494