Measurement and correction of misalignments in corneal topography using the null-screen method

被引:9
|
作者
Campos-Garcia, Manuel [1 ]
Aguirre-Aguirre, Daniel [1 ]
Ivan Moreno-Oliva, Victor [2 ]
Huerta-Carranza, Oliver [1 ]
de Emanuel Armengol-Cruz, Victor [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Apdo Postal 70-186, Mexico City 04510, DF, Mexico
[2] Univ Istmo, Ciudad Univ S-N, Tehuantepec 70760, Oax, Mexico
关键词
SURFACES;
D O I
10.1364/OSAC.409933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Misalignments are a common problem in corneal topography reconstruction. To determine the topography of the surface using a corneal topographer based on the null-screen method, it is necessary to measure errors caused by mechanical misalignment of the topographer, which could influence the results of this technique but are not related to the quality of the corneal surface. To evaluate the variability in measurements, in this work, we simulate some misalignments in the optical system, for the simulation we design a semi-radial null-screen to test a reference spherical surface to identify the variations in results introduced by misalignment errors of the corneal topographer with respect to the test surface. According to the simulations, the accuracy of the null-screen method ranges from 0.81 mu m to 2.84 mu m for typical tilt, decentering, and defocusing errors. Experimental results for the testing of a spherical surface are shown. After removing the misalignments, we found that the variations are approximately 3.5 mu m rms value measured with respect to the best-fitting sphere, and the radius of curvature differs approximately 0.06% from the design value. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:158 / 170
页数:13
相关论文
共 50 条
  • [31] Corneal Topography Using Dynamic Point Shifting Method in Quadrangular OLED's Prism
    Rodriguez-Rodriguez, M. I.
    Juarez, Carlos Enrique Valderrama
    Zamacona, Juan Ricardo Damian
    Diaz-Uribe, R.
    OPTICAL MANUFACTURING AND TESTING XIV, 2022, 12221
  • [32] Measurement error correction using iterative method and oversampling
    Kamensky, M.
    Kovac, K.
    MEASUREMENT 2007: 6TH INTERNATIONAL CONFERENCE ON MEASUREMENT, PROCEEDINGS, 2007, : 38 - +
  • [33] Simultaneous Corneal Topography and Epithelial Thickness Mapping from a Single Measurement Using Optical Coherence Tomography
    Sikorski, Bartosz L.
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [34] Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study
    Kobashi, Hidenaga
    Tsubota, Kazuo
    Aoki, Shunsuke
    Kobayashi, Masaaki
    Sumali, Brian
    Mitsukura, Yasue
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (07) : 2199 - 2207
  • [35] CONTACT-LENS FITTING IN CORNEAL TOPOGRAPHY USING SIMULATED SAGITTAL RADIUS METHOD (SRM)
    MATALLANA, M
    WEISS, C
    OLTRUP, T
    JEAN, B
    BENDE, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S1033 - S1033
  • [36] Surgically-induced prismatic and refractive correction after refractive keratotomy using Fourier analysis of corneal topography.
    Azar, DT
    Proctor, S
    Leitman, T
    Azar, NF
    Raasch, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2564 - 2564
  • [37] Null method for four-point probe measurement using high resistance probes
    Ishikawa, Makoto
    Yoshimura, Masamichi
    Ueda, Kazuyuki
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2006, 4 : 115 - 117
  • [38] Comparison of Central Corneal Thickness Measurement Using Ultrasonic Pachymetry, Rotating Scheimpflug Camera, and Scanning-Slit Topography
    Sedaghat, Mohammad Reza
    Daneshvar, Ramin
    Kargozar, Abbas
    Derakhshan, Akbar
    Daraei, Mona
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 780 - 789
  • [39] Experimental correction of irregular corneal astigmatism using topography-based flying-spot-mode excimer laser photoablation
    Seitz, B
    Langenbucher, A
    Kus, MM
    Harrer, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (02) : 252 - 256
  • [40] A multivariate method for measurement error correction using pairs of concentration biomarkers
    Fraser, Gary E.
    Yan, Ru