Measurement and correction of misalignments in corneal topography using the null-screen method

被引:9
|
作者
Campos-Garcia, Manuel [1 ]
Aguirre-Aguirre, Daniel [1 ]
Ivan Moreno-Oliva, Victor [2 ]
Huerta-Carranza, Oliver [1 ]
de Emanuel Armengol-Cruz, Victor [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Ciencias Aplicadas & Tecnol, Apdo Postal 70-186, Mexico City 04510, DF, Mexico
[2] Univ Istmo, Ciudad Univ S-N, Tehuantepec 70760, Oax, Mexico
关键词
SURFACES;
D O I
10.1364/OSAC.409933
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Misalignments are a common problem in corneal topography reconstruction. To determine the topography of the surface using a corneal topographer based on the null-screen method, it is necessary to measure errors caused by mechanical misalignment of the topographer, which could influence the results of this technique but are not related to the quality of the corneal surface. To evaluate the variability in measurements, in this work, we simulate some misalignments in the optical system, for the simulation we design a semi-radial null-screen to test a reference spherical surface to identify the variations in results introduced by misalignment errors of the corneal topographer with respect to the test surface. According to the simulations, the accuracy of the null-screen method ranges from 0.81 mu m to 2.84 mu m for typical tilt, decentering, and defocusing errors. Experimental results for the testing of a spherical surface are shown. After removing the misalignments, we found that the variations are approximately 3.5 mu m rms value measured with respect to the best-fitting sphere, and the radius of curvature differs approximately 0.06% from the design value. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:158 / 170
页数:13
相关论文
共 50 条
  • [21] Sagittal and meridional radii of curvature for a surface with symmetry of revolution by using a null-screen testing method
    Estrada-Molina, Amilcar
    Campos-Garcia, Manuel
    Diaz-Uribe, Rufino
    APPLIED OPTICS, 2013, 52 (04) : 625 - 634
  • [22] Surface shape evaluation with a corneal topographer based on a conical null-screen with a novel radial point distribution
    Campos-Garcia, Manuel
    Cossio-Guerrero, Cesar
    Ivan Moreno-Oliva, Victor
    Huerta-Carranza, Oliver
    APPLIED OPTICS, 2015, 54 (17) : 5411 - 5419
  • [23] Improvements in the evaluation of parabolic trough solar collector using a dynamic flat null-screen
    Huerta-Carranza, Oliver
    Campos-Garcia, Manuel
    Aguirre-Aguirre, Daniel
    Villalobos-Mendoza, Brenda
    Ivan Moreno-Oliva, Victor
    OPTICAL FABRICATION, TESTING, AND METROLOGY VII, 2021, 11873
  • [24] Improved quantitative testing of a non-symmetric convex surface using a conical null-screen
    Campos-Garcia, Manuel
    Bautista-Clemente, Francisco Javier
    Cruz-Felix, Angel Sinue
    Santiago-Alvarado, Agustin
    Huerta-Carranza, Oliver
    Aguirre-Aguirre, Daniel
    Moreno-Oliva, Victor Ivan
    OPTICAL MANUFACTURING AND TESTING XIV, 2022, 12221
  • [25] Measurement of the topography of human cadaver lenses using the PAR Corneal Topography System
    Fernandez, V
    Manns, F
    Zipper, S
    Sandadi, S
    Hamaoui, M
    Tahi, H
    Ho, A
    Parel, JM
    OPHTHALMIC TECHNOLOGIES XI, 2001, 4245 : 113 - 118
  • [26] Dynamic point shifting with null screens using three LCDs as targets for corneal topography
    Rodriguez-Rodriguez, M. I.
    Jaramillo-Nunez, A.
    Diaz-Uribe, R.
    APPLIED OPTICS, 2015, 54 (22) : 6698 - 6710
  • [27] SILICON CAST METHOD FOR INVIVO MEASUREMENT OF CORNEAL TOPOGRAPHY (WOUND-HEALING) AFTER PRK
    BACHMANN, W
    JEAN, B
    BENDE, T
    SEILER, T
    THIEL, HJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 764 - 764
  • [28] ABSOLUTE MEASUREMENT OF HIGH VOLTAGE BY A NULL METHOD USING STRAIN GAUGES
    BROADBEN.TE
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (03): : 341 - &
  • [29] Prospects of Using a Modified Null Method for Temperature Measurement with Resistance Sensors
    Filatov, A. V.
    Serdyukov, K. A.
    Novikova, A. A.
    MEASUREMENT TECHNIQUES, 2020, 63 (07) : 567 - 572
  • [30] Prospects of Using a Modified Null Method for Temperature Measurement with Resistance Sensors
    A. V. Filatov
    K. A. Serdyukov
    A. A. Novikova
    Measurement Techniques, 2020, 63 : 567 - 572