Dosimetric assessment of a single-energy metal artifact reduction algorithm for computed tomography images in radiation therapy

被引:7
|
作者
Murazaki, Hiroo [1 ]
Fukunaga, Junichi [1 ]
Hirose, Taka-aki [1 ]
Funatsu, Naomi [1 ]
Matsumoto, Ryoji [1 ]
Hidaka, Kyohei [1 ]
Nagamine, Shuji [1 ]
Nakanishi, Daiki [1 ]
Kato, Toyoyuki [1 ]
机构
[1] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
关键词
Metal artifact reduction; Single-energy metal artifact reduction; Radiation treatment planning; Dose distribution; ANISOTROPIC ANALYTICAL ALGORITHM; ACUROS XB; DOSE CALCULATION; CT; QUALITY; IMPACT; SIMULATION; AAA;
D O I
10.1007/s12194-019-00517-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to evaluate the performance of a single-energy metal artifact reduction (SEMAR) algorithm for radiation therapy treatment using phantom cases with metal inserts, assess improvements in computed tomography (CT) number accuracy, and investigate its effects on treatment planning dosimetry. A standard electron density phantom was scanned with and without metal inserts. The numbers of tissue-equivalent materials on both uncorrected and SEMAR-corrected CT images were compared. Treatment planning accuracy was evaluated by comparing dose distributions computed using true density images (without metal inserts), uncorrected images (with metal inserts), and SEMAR-corrected images (with metal inserts) using three-dimensional gamma analysis. The numbers of the true density and uncorrected and SEMAR-corrected CT images in a muscle plug with unilateral inserts were 25.9 HU, - 281.8 HU, and 26.1 HU, respectively. A similar tendency was obtained for other tissue-equivalent materials, and the numbers on CT images were improved with the SEMAR algorithm. In cases involving 1 portal irradiation, 10-MV X-ray, and the Acuros XB algorithm, the pass ratio between the true density and uncorrected images was 89.89%, while that between the true density and SEMAR-corrected images was 95.03%. Improvements in dose distribution were evident using the SEMAR algorithm. Similar trends were found for different irradiation methods and dose calculation algorithms. The SEMAR algorithm can significantly reduce metal artifacts on CT images used for radiation treatment planning. This aspect influenced dosimetry in the region of the artifact and dose distribution was significantly improved with use of the SEMAR-corrected images.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 50 条
  • [31] Combined Dual-Energy and Single-Energy Metal Artifact Reduction Techniques Versus Single-Energy Techniques Alone for Lesion Detection Near an Arthroplasty
    Chandrasekar, Suraj
    Colak, Ceylan
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Karim, Wadih
    Subhas, Naveen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 425 - 432
  • [32] Metal Artifact Reduction and Metal Attenuation Estimation for On-Board Cone Beam Computed Tomography in Modern Radiation Therapy
    Xu, Q.
    Sano, M.
    Yang, Y.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E692 - E692
  • [33] Single-Energy Retrospective Metal Artifact Reduction Using Adaptive Thresholding for Metal Implants in the Abdomen and Pelvis
    Dommaraju, Sujithraj
    Nakhaei, Masoud
    Zhang, Da
    Camacho, Andres
    Boos, Johannes
    Appel, Elisabeth
    Brook, Olga R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 443 - 449
  • [34] Single-Energy Retrospective Metal Artifact Reduction Using Adaptive Thresholding for Metal Implants in the Abdomen and Pelvis
    Dommaraju, Sujithraj
    Nakhaei, Masoud
    Zhang, Da
    Camacho, Andres
    Boos, Johannes
    Appel, Elisabeth
    Brook, Olga R.
    Brook, Olga R. (obrook@bidmc.harvard.edu), 1600, Lippincott Williams and Wilkins (44): : 443 - 449
  • [35] Application of metal artifact reduction algorithm in reducing metal artifacts in post-surgery pediatric low radiation dose spine computed tomography (CT) images
    Sun, Jihang
    Li, Haoyan
    Yu, Tong
    Huo, Aihua
    Hua, Shan
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (07) : 4648 - 4658
  • [36] Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants
    Wei, Fanqin
    Li, Jiahui
    Zhou, Chunxiang
    Li, Yun
    Wang, Xianren
    Huang, Bixue
    Sun, Qiyang
    Xiong, Guanxia
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 49 (01)
  • [37] Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants
    Fanqin Wei
    Jiahui Li
    Chunxiang Zhou
    Yun Li
    Xianren Wang
    Bixue Huang
    Qiyang Sun
    Guanxia Xiong
    Journal of Otolaryngology - Head & Neck Surgery, 49
  • [38] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Fabian Bamberg
    Alexander Dierks
    Konstantin Nikolaou
    Maximilian F. Reiser
    Christoph R. Becker
    Thorsten R. C. Johnson
    European Radiology, 2011, 21 : 1424 - 1429
  • [39] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [40] Metal artifact reduction for oral and maxillofacial computed tomography images by a generative adversarial network
    Xu, Lei
    Zhou, Shanluo
    Guo, Jixiang
    Tian, Weidong
    Tang, Wei
    Yi, Zhang
    APPLIED INTELLIGENCE, 2022, 52 (11) : 13184 - 13194