Dosimetric assessment of a single-energy metal artifact reduction algorithm for computed tomography images in radiation therapy

被引:7
|
作者
Murazaki, Hiroo [1 ]
Fukunaga, Junichi [1 ]
Hirose, Taka-aki [1 ]
Funatsu, Naomi [1 ]
Matsumoto, Ryoji [1 ]
Hidaka, Kyohei [1 ]
Nagamine, Shuji [1 ]
Nakanishi, Daiki [1 ]
Kato, Toyoyuki [1 ]
机构
[1] Kyushu Univ Hosp, Dept Med Technol, Div Radiol, 3-1-1 Maidashi, Fukuoka, Fukuoka 8128582, Japan
关键词
Metal artifact reduction; Single-energy metal artifact reduction; Radiation treatment planning; Dose distribution; ANISOTROPIC ANALYTICAL ALGORITHM; ACUROS XB; DOSE CALCULATION; CT; QUALITY; IMPACT; SIMULATION; AAA;
D O I
10.1007/s12194-019-00517-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to evaluate the performance of a single-energy metal artifact reduction (SEMAR) algorithm for radiation therapy treatment using phantom cases with metal inserts, assess improvements in computed tomography (CT) number accuracy, and investigate its effects on treatment planning dosimetry. A standard electron density phantom was scanned with and without metal inserts. The numbers of tissue-equivalent materials on both uncorrected and SEMAR-corrected CT images were compared. Treatment planning accuracy was evaluated by comparing dose distributions computed using true density images (without metal inserts), uncorrected images (with metal inserts), and SEMAR-corrected images (with metal inserts) using three-dimensional gamma analysis. The numbers of the true density and uncorrected and SEMAR-corrected CT images in a muscle plug with unilateral inserts were 25.9 HU, - 281.8 HU, and 26.1 HU, respectively. A similar tendency was obtained for other tissue-equivalent materials, and the numbers on CT images were improved with the SEMAR algorithm. In cases involving 1 portal irradiation, 10-MV X-ray, and the Acuros XB algorithm, the pass ratio between the true density and uncorrected images was 89.89%, while that between the true density and SEMAR-corrected images was 95.03%. Improvements in dose distribution were evident using the SEMAR algorithm. Similar trends were found for different irradiation methods and dose calculation algorithms. The SEMAR algorithm can significantly reduce metal artifacts on CT images used for radiation treatment planning. This aspect influenced dosimetry in the region of the artifact and dose distribution was significantly improved with use of the SEMAR-corrected images.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 50 条
  • [21] Customized Total Variation Algorithm for Metal Artifact Reduction in Computed Tomography
    Deng, Ziheng
    Zhou, Yufu
    Zhang, Weikang
    Lin, Zefan
    Zhao, Jun
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3479 - 3482
  • [22] Dual-Energy Computed Tomography: Is There a Penalty in Image Quality and Radiation Dose Compared With Single-Energy Computed Tomography?
    Thomas, Christoph
    Ketelsen, Dominik
    Tsiflikas, Ilias
    Reimann, Anja
    Brodoefel, Harald
    Claussen, Claus D.
    Heuschmid, Martin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (02) : 309 - 315
  • [23] A methodical assessment of interpolation techniques to metal artifact reduction in Computed Tomography
    Souza Paulino, Jose Alberto
    de Sousa, Robson Pequeno
    Dantas de Almeida, Carlos Wilson
    Valadares Oliveira, Eduardo Jorge
    Galdino, Katia Elizabete
    de Morals, Misael Elias
    2019 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2019, : 2428 - 2432
  • [24] Flexible Generation of Prior Images for Metal Artifact Reduction in Industrial Computed Tomography
    Zemek, Marek
    Šalplachta, Jakub
    Zikmund, Tomáš
    Kaiser, Jozef
    e-Journal of Nondestructive Testing, 2022, 27 (03):
  • [25] Evaluation of Metal Artifact Reduction (MAR) Software On Computed Tomography (CT) Images
    Huang, V.
    Kohli, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3244 - 3244
  • [26] GATED CONVOLUTIONAL NETWORK FOR METAL ARTIFACT REDUCTION IN COMPUTED TOMOGRAPHY IMAGES.
    Bera, Sutanu
    Biswas, Prabir Kumar
    2022 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP, 2022, : 4118 - 4122
  • [27] Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomography Images
    Korpics, M.
    Alite, F.
    Block, A. M.
    Choi, M.
    Harkenrider, M. M.
    Solanki, A. A.
    Surucu, M.
    Roeske, J. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E663 - E663
  • [28] Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization
    Asano, Yudai
    Tada, Akihiro
    Shinya, Takayoshi
    Masaoka, Yoshihisa
    Iguchi, Toshihiro
    Sato, Shuhei
    Kanazawa, Susumu
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (04) : 285 - 294
  • [29] Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization
    Yudai Asano
    Akihiro Tada
    Takayoshi Shinya
    Yoshihisa Masaoka
    Toshihiro Iguchi
    Shuhei Sato
    Susumu Kanazawa
    Japanese Journal of Radiology, 2018, 36 : 285 - 294
  • [30] A Prior-interpolation Based Metal Artifact Reduction Algorithm in Computed Tomography
    Li, Ming
    Liu, Zhaobang
    Dong, Yuefang
    Su, Kai
    Luo, Kangxin
    2014 7TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2014), 2014, : 24 - 28