Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants

被引:6
|
作者
Wei, Fanqin [1 ,2 ,3 ]
Li, Jiahui [1 ,2 ,3 ,4 ]
Zhou, Chunxiang [1 ,2 ,3 ]
Li, Yun [1 ,2 ,3 ]
Wang, Xianren [1 ,2 ,3 ]
Huang, Bixue [1 ,2 ,3 ]
Sun, Qiyang [1 ,2 ,3 ]
Xiong, Guanxia [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Otorhinolaryngol Head & Neck Surg, 2nd Zhongshan Rd 58, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Inst Otorhinolaryngol Head & Neck Surg, Guangzhou 510080, Guangdong, Peoples R China
[3] Guangzhou Key Lab Otorhinolaryngol, Guangzhou 510080, Guangdong, Peoples R China
[4] Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
关键词
SEMAR; electrode; Image quality; Computed tomography; ELECTRODE ARRAY; TEMPORAL BONE; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CT; SURGERY; LOCALIZATION; INSERTION; POSITION; HIP;
D O I
10.1186/s40463-020-00462-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background The purpose of this study was to develop an effective method of reducing metal artifacts in cochlear implant (CI) electrodes. Methods The temporal bones of 30 patients (34 ears) after CI were examined with 320-detector row computed tomography, which was evaluated by two senior radiologists using a double-blind method. Noise, artifact index, signal-to-noise ratio, and the subjective image quality score were compared before versus after using single-energy metal artifact reduction (SEMAR). The electrode position, single electrode visibility, and electrode count were evaluated using SEMAR combined with either multi-planar reconstruction (MPR) or maximum intensity projection. Results The two radiologists' measurements had good consistency. SEMAR significantly reduced the image noise and artifacts index and significantly improved the signal-to-noise ratio and subjective image quality score (P < 0.01). The combination of SEMAR with MPR was conducive to accurate assessment of electrode position and single-electrode visibility. The combination of SEMAR with MIP facilitated accurate and intuitive matching of the assessed electrode count with the number of electrodes implanted during the operation (P = 0.062). Conclusion SEMAR significantly reduces metal artifacts generated by CI electrodes and improves the quality of computed tomography images. The combination of SEMAR with MPR and maximum intensity projection is beneficial for evaluating the position and number of CI electrodes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants
    Fanqin Wei
    Jiahui Li
    Chunxiang Zhou
    Yun Li
    Xianren Wang
    Bixue Huang
    Qiyang Sun
    Guanxia Xiong
    Journal of Otolaryngology - Head & Neck Surgery, 49
  • [2] Combined Dual-Energy and Single-Energy Metal Artifact Reduction Techniques Versus Single-Energy Techniques Alone for Lesion Detection Near an Arthroplasty
    Chandrasekar, Suraj
    Colak, Ceylan
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Karim, Wadih
    Subhas, Naveen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 425 - 432
  • [3] Single-Energy Retrospective Metal Artifact Reduction Using Adaptive Thresholding for Metal Implants in the Abdomen and Pelvis
    Dommaraju, Sujithraj
    Nakhaei, Masoud
    Zhang, Da
    Camacho, Andres
    Boos, Johannes
    Appel, Elisabeth
    Brook, Olga R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 443 - 449
  • [4] Single-Energy Retrospective Metal Artifact Reduction Using Adaptive Thresholding for Metal Implants in the Abdomen and Pelvis
    Dommaraju, Sujithraj
    Nakhaei, Masoud
    Zhang, Da
    Camacho, Andres
    Boos, Johannes
    Appel, Elisabeth
    Brook, Olga R.
    Brook, Olga R. (obrook@bidmc.harvard.edu), 1600, Lippincott Williams and Wilkins (44): : 443 - 449
  • [5] Deep learning reconstruction with single-energy metal artifact reduction in pelvic computed tomography for patients with metal hip prostheses
    Hosoi, Reina
    Yasaka, Koichiro
    Mizuki, Masumi
    Yamaguchi, Haruomi
    Miyo, Rintaro
    Hamada, Akiyoshi
    Abe, Osamu
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (08) : 863 - 871
  • [6] Deep learning reconstruction with single-energy metal artifact reduction in pelvic computed tomography for patients with metal hip prostheses
    Reina Hosoi
    Koichiro Yasaka
    Masumi Mizuki
    Haruomi Yamaguchi
    Rintaro Miyo
    Akiyoshi Hamada
    Osamu Abe
    Japanese Journal of Radiology, 2023, 41 : 863 - 871
  • [7] Single-Energy Metal Artifact Reduction (SEMAR) in Ultra-High-Resolution CT Angiography of Patients with Intracranial Implants
    Jabas, Abdullah
    Mercado, Mario Alberto Abello
    Altmann, Sebastian
    Ringel, Florian
    Booz, Christian
    Kronfeld, Andrea
    Sanner, Antoine P.
    Brockmann, Marc A.
    Othman, Ahmed E.
    DIAGNOSTICS, 2023, 13 (04)
  • [8] Influence of field of view size and reconstruction methods on single-energy metal artifact reduction: a phantom study
    Tsuboi, Kunihito
    Osaki, Naoko
    Ohtani, Yuki
    Tanikawa, Ken
    Kaneko, Masanori
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (02) : 637 - 642
  • [9] Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses
    Koichiro Yasaka
    Eriko Maeda
    Shouhei Hanaoka
    Masaki Katsura
    Jiro Sato
    Kuni Ohtomo
    Japanese Journal of Radiology, 2016, 34 : 625 - 632
  • [10] Influence of field of view size and reconstruction methods on single-energy metal artifact reduction: a phantom study
    Kunihito Tsuboi
    Naoko Osaki
    Yuki Ohtani
    Ken Tanikawa
    Masanori Kaneko
    Physical and Engineering Sciences in Medicine, 2022, 45 : 637 - 642