Combined application of single-energy metal artifact reduction and reconstruction techniques in patients with Cochlear implants

被引:8
|
作者
Wei, Fanqin [1 ,2 ,3 ]
Li, Jiahui [1 ,2 ,3 ,4 ]
Zhou, Chunxiang [1 ,2 ,3 ]
Li, Yun [1 ,2 ,3 ]
Wang, Xianren [1 ,2 ,3 ]
Huang, Bixue [1 ,2 ,3 ]
Sun, Qiyang [1 ,2 ,3 ]
Xiong, Guanxia [1 ,2 ,3 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Otorhinolaryngol Head & Neck Surg, 2nd Zhongshan Rd 58, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Inst Otorhinolaryngol Head & Neck Surg, Guangzhou 510080, Guangdong, Peoples R China
[3] Guangzhou Key Lab Otorhinolaryngol, Guangzhou 510080, Guangdong, Peoples R China
[4] Guangzhou Women & Childrens Med Ctr, Guangzhou 510623, Guangdong, Peoples R China
关键词
SEMAR; electrode; Image quality; Computed tomography; ELECTRODE ARRAY; TEMPORAL BONE; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CT; SURGERY; LOCALIZATION; INSERTION; POSITION; HIP;
D O I
10.1186/s40463-020-00462-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background The purpose of this study was to develop an effective method of reducing metal artifacts in cochlear implant (CI) electrodes. Methods The temporal bones of 30 patients (34 ears) after CI were examined with 320-detector row computed tomography, which was evaluated by two senior radiologists using a double-blind method. Noise, artifact index, signal-to-noise ratio, and the subjective image quality score were compared before versus after using single-energy metal artifact reduction (SEMAR). The electrode position, single electrode visibility, and electrode count were evaluated using SEMAR combined with either multi-planar reconstruction (MPR) or maximum intensity projection. Results The two radiologists' measurements had good consistency. SEMAR significantly reduced the image noise and artifacts index and significantly improved the signal-to-noise ratio and subjective image quality score (P < 0.01). The combination of SEMAR with MPR was conducive to accurate assessment of electrode position and single-electrode visibility. The combination of SEMAR with MIP facilitated accurate and intuitive matching of the assessed electrode count with the number of electrodes implanted during the operation (P = 0.062). Conclusion SEMAR significantly reduces metal artifacts generated by CI electrodes and improves the quality of computed tomography images. The combination of SEMAR with MPR and maximum intensity projection is beneficial for evaluating the position and number of CI electrodes.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography
    Masaki Katsura
    Jiro Sato
    Masaaki Akahane
    Taku Tajima
    Toshihiro Furuta
    Harushi Mori
    Osamu Abe
    Neuroradiology, 2018, 60 : 1141 - 1150
  • [32] Metal Artifact Reduction for Orthopedic Implants: Brain CT Angiography in Patients with Intracranial Metallic Implants
    Sunwoo, Leonard
    Park, Sun-Won
    Rhim, Jung Hyo
    Kang, Yeonah
    Chung, Young Seob
    Son, Young-Je
    Kim, Soo Chin
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2018, 33 (21)
  • [33] Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers
    Hirata, Kenichiro
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kidoh, Masafumi
    Funama, Yoshinori
    Yuki, Hideaki
    Yoshida, Morikatsu
    Yamashita, Yasuyuki
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (10) : 650 - 656
  • [34] Metal Artifact Reduction Algorithm for Single Energy and Dual Energy CT Scans
    Chang, Yu-Bing
    Xu, Dan
    Zamyatin, Alexander A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3426 - 3429
  • [35] Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers
    Kenichiro Hirata
    Daisuke Utsunomiya
    Seitaro Oda
    Masafumi Kidoh
    Yoshinori Funama
    Hideaki Yuki
    Morikatsu Yoshida
    Yasuyuki Yamashita
    Japanese Journal of Radiology, 2015, 33 : 650 - 656
  • [36] Metal Artifact Reduction: Added Value of Rapid-Kilovoltage-Switching Dual-Energy CT in Relation to Single-Energy CT in a Piglet Animal Model
    Takrouri, Heba S.
    Alnassar, Mutaz M.
    Amirabadi, Afsaneh
    Babyn, Paul S.
    Moineddin, Rahim
    Padfield, Nancy L.
    BenDavid, Guila
    Doria, Andrea S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) : W352 - W359
  • [37] Metal Artifact Reduction Computed Tomography of Arthroplasty Implants Effects of Combined Modeled Iterative Reconstruction and Dual-Energy Virtual Monoenergetic Extrapolation at Higher Photon Energies
    Khodarahmi, Iman
    Haroun, Reham R.
    Lee, Moses
    Fung, George S. K.
    Fuld, Matthew K.
    Schon, Lew C.
    Fishman, Elliot K.
    Fritz, Jan
    INVESTIGATIVE RADIOLOGY, 2018, 53 (12) : 728 - 735
  • [38] Metal artifact reduction using mono-energy images combined with metal artifact reduction software in spectral computed tomography: a study on phantoms
    Sun, Xiaoli
    Zhao, Qingqing
    Sun, Pengtao
    Yao, Zhipeng
    Wang, Rengui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (07) : 1515 - 1525
  • [39] Single-energy versus dual-energy imaging during CT-guided biopsy using dedicated metal artifact reduction algorithm in an in vivo pig model
    Thuy Duong Do
    Heim, Julia
    Skornitzke, Stephan
    Melzig, Claudius
    Vollherbst, Dominik F.
    Faerber, Michael
    Pereira, Philippe L.
    Kauczor, Hans-Ulrich
    Sommer, Christof Matthias
    PLOS ONE, 2021, 16 (04):
  • [40] Potential of computed tomography with iterative metal artifact reduction algorithm for proton therapy of patients with metal implants
    Belloni, S.
    Peroni, M.
    Bolsi, A.
    Niemann, T.
    Engelhardt, D.
    Fachouri, N.
    Perrin, R.
    Walser, M.
    Fattori, G.
    Kubik-Huch, R. A.
    Lomax, A. J.
    Weber, D. C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 843 - 843