Comparative Study of Pulsed Versus Continuous High-Intensity Focused Ultrasound Ablation Using in vitro and in vivo Models

被引:7
|
作者
Wang, Yanhao [1 ,2 ]
Wang, Qi [1 ]
Luo, Yong [1 ]
Jiang, Lu [1 ]
Zeng, Zihuan [1 ]
Gan, Lidan [1 ]
Chen, Jianli [1 ]
Han, Hongfei [1 ]
Zou, Jianzhong [1 ]
机构
[1] Chongqing Med Univ, State Key Lab Ultrasound Engn Med Cofounded Chon, Chongqing Collaborat Innovat Ctr Minimally Invasi, Coll Biomed Engn, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Coll Stomatol, Chongqing 401147, Peoples R China
基金
美国国家科学基金会;
关键词
ablation; comparison; duty cycle; high-intensity focused ultrasound; identical doses; CAVITATIONAL ULTRASOUND; NONINVASIVE THERAPY; TISSUE; HIFU; EMBOLIZATION; FEASIBILITY; BACKSCATTER;
D O I
10.1002/jum.15098
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To compare the efficacy of pulsed high-intensity focused ultrasound (PHIFU) versus continuous high-intensity focused ultrasound (CHIFU) ablation at identical doses. Methods Continuous and pulsed HIFU (1200 J) at duty cycles (DCs) of 60% and 20% were examined for their capacity to ablate bovine liver tissue in vitro and rabbit liver tissue in vivo. After ablation, grayscale changes and pathologic characteristics were observed or measured, and the tissue necrosis volume, energy efficiency factor, and average grayscale density were calculated. Results The pulsed mode generated greater liquefaction necrosis. An inconspicuous grayscale change was observed for PHIFU at a DC of 20% in some samples, which appeared as an elliptical cavity. The energy efficiency factor of PHIFU at a DC of 60% was significantly lower than that of CHIFU, as observed both in vitro and in vivo (P < .05). The grayscale value and average grayscale density in response to CHIFU were significantly greater than those in response to PHIFU (60% or 20%; P < .05). Histopathologic analysis revealed liquefaction necrosis in all PHIFU groups. Conclusions At identical doses, compared with CHIFU, a single session of PHIFU can generate liquefaction necrosis and at a higher DC can improve ablation efficiency. This increased efficacy of PHIFU may involve enhancement of tissue destruction by cavitation effects and a reduction in the obstruction effect of endogenous microbubbles through cavitation effects or a more effective diffusion of heat.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 50 条
  • [21] Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation
    Zhou, Yufeng
    [J]. ULTRASOUND QUARTERLY, 2017, 33 (04) : 253 - 260
  • [22] Focal High-Intensity Focused Ultrasound Ablation of the Prostate
    Abrams, Lauren R.
    Koch, Michael O.
    Bahler, Clinton D.
    [J]. JOURNAL OF ENDOUROLOGY, 2021, 35 : S24 - S32
  • [23] High-intensity focused ultrasound for endometrial ablation in adenomyosis: a clinical study
    Wu, Siyun
    Liu, Jun
    Liu, Xiaoshan
    Han, Yanhua
    [J]. FRONTIERS IN MEDICINE, 2024, 11
  • [24] High-intensity focused ultrasound ablation around the tubing
    Siu, Jun Yang
    Liu, Chenhui
    Zhou, Yufeng
    [J]. PLOS ONE, 2017, 12 (11):
  • [25] High-intensity focused ultrasound ablation of breast cancer
    Wu, Feng
    ter Haar, Gail
    Chen, Wei R.
    [J]. EXPERT REVIEW OF ANTICANCER THERAPY, 2007, 7 (06) : 823 - 831
  • [26] Comparative Study of Lesions Created by High-Intensity Focused Ultrasound Using Sequential Discrete and Continuous Scanning Strategies
    Fan, Tingbo
    Liu, Zhenbo
    Zhang, Dong
    Tang, Mengxing
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (03) : 763 - 769
  • [27] An in vitro and in vivo study on extracorporeal transducer optimization for high-intensity focused ultrasound to improve the safety and efficacy of breast tumor ablation
    Hong, Liu
    Zhang, Wendy
    Pan, Feibao
    Xiaobo, Gong
    Huang, Haoran
    You, Yaqing
    Deng, Lulu
    Wang, Zhibiao
    Zhang, Cai
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
  • [28] Influence of High-Intensity Focused Ultrasound (HIFU) Ablation on Arteries: Ex Vivo Studies
    Zhou, Yufeng
    Lim, Wei Chun Daniel
    [J]. MICROMACHINES, 2021, 12 (05)
  • [29] Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation
    Wen Luo
    Xiaodong Zhou
    Xue Tian
    Xialong Ren
    Minjuan Zheng
    Kejun Gu
    Guangbin He
    [J]. Advances in Therapy, 2006, 23 : 861 - 868
  • [30] Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation
    Luo, Wen
    Zhou, Xiaodong
    Tian, Xue
    Ren, Xialong
    Zheng, Minjuan
    Gu, Kejun
    He, Guangbin
    [J]. ADVANCES IN THERAPY, 2006, 23 (06) : 861 - 868