Influence of High-Intensity Focused Ultrasound (HIFU) Ablation on Arteries: Ex Vivo Studies

被引:8
|
作者
Zhou, Yufeng [1 ,2 ,3 ]
Lim, Wei Chun Daniel [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[2] Chongqing Med Univ, Coll Biomed Engn, State Key Lab Ultrasound Med & Engn, Chongqing 400016, Peoples R China
[3] Chongqing Med Univ, Chongqing Key Lab Biomed Engn, Chongqing 400016, Peoples R China
关键词
high-intensity focused ultrasound (HIFU); thermal lesion; mechanical effect; cavitation; BLOOD-VESSELS; EXPOSURE;
D O I
10.3390/mi12050485
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-intensity focused ultrasound (HIFU) has been used to ablate solid tumors and cancers. Because of the hypervascular structure of the tumor and circulating blood inside it, the interaction between the HIFU burst and vessel is a critical issue in the clinical environment. Influences on lesion production and the potential of vessel rupture were investigated in this study for the efficiency and safety of clinical ablation. An extracted porcine artery was embedded in a transparent polyacrylamide gel phantom, with bovine serum albumin (BSA) as an indicator of the thermal lesion, and degassed water was driven through the artery sample. The HIFU focus was aligned to the anterior wall, middle of the artery, and posterior wall. After HIFU ablation, the produced lesion was photographically recorded, and then its size was quantified and compared with that in the gel phantom without artery. In addition, the bubble dynamics (i.e., generation, expansion, motion, and shrinkage of bubbles and their interaction with the artery) were captured using high-speed imaging. It was found that the presence of the artery resulted in a decrease in lesion size in both the axial and lateral directions. The characteristics of the lesion are dependent on the focus alignment. Acoustic and hydrodynamic cavitation play important roles in lesion production and interaction with the artery. Both thermal and mechanical effects were found on the surface of the artery wall after HIFU ablation. However, no vessel rupture was found in this ex vivo study.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Control parameters for high-intensity focused ultrasound (HIFU) for tissue ablation in the ex-vivo kidney
    Köhrmann, KU
    Michel, MS
    Steidler, A
    Marlinghaus, EH
    Kraut, O
    Alken, P
    [J]. AKTUELLE UROLOGIE, 2002, 33 (01) : 58 - 63
  • [2] Characterization and Ex Vivo evaluation of an extracorporeal high-intensity focused ultrasound (HIFU) system
    Zhou, Yufeng
    Cunitz, Bryan W.
    Dunmire, Barbrina
    Wang, Yak-Nam
    Karl, Steven G.
    Warren, Cinderella
    Mitchell, Stuart
    Hwang, Joo Ha
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 345 - 359
  • [3] HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION OF EX VIVO BOVINE ACHILLES TENDON
    Muratore, Robert
    Akabas, Tal
    Muratore, Isabella B.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (12): : 2043 - 2050
  • [4] Transsclera Drug Delivery by Pulsed High-Intensity Focused Ultrasound (HIFU): An Ex Vivo Study
    Murugappan, Suresh Kanna
    Zhou, Yufeng
    [J]. CURRENT EYE RESEARCH, 2015, 40 (11) : 1172 - 1180
  • [5] High-intensity focused ultrasound (HIFU) ablation in patients with hepatocellular carcinoma
    Jung, S. E.
    Cho, S. H.
    Han, J. Y.
    Hahn, S. T.
    Piao, X.
    [J]. JOURNAL OF HEPATOLOGY, 2008, 48 : S147 - S147
  • [6] In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode
    Dai, Hongya
    Chen, Fei
    Yan, Sijing
    Ding, Xiaoya
    Ma, Dazhao
    Wen, Jing
    Xu, Die
    Zou, Jianzhong
    [J]. MEDICAL SCIENCE MONITOR, 2017, 23 : 3373 - 3382
  • [7] High-intensity focused ultrasound for ex vivo kidney tissue ablation:: Influence of generator power and pulse duration
    Häcker, A
    Köhrmann, KU
    Knoll, T
    Langbein, S
    Steidler, A
    Kraut, O
    Marlinghaus, E
    Alken, P
    Michel, MS
    [J]. JOURNAL OF ENDOUROLOGY, 2004, 18 (09) : 917 - 924
  • [8] Noninvasive cardiac arrhythmia therapy using High-Intensity Focused Ultrasound (HIFU) ablation
    Wu, Qi
    Zhou, Qi
    Zhu, Que
    Rong, Shunkang
    Wang, Qi
    Guo, Rui
    Deng, Changming
    Liu, Dichuan
    Yang, Gang
    Jiang, Yonghong
    Wang, Zhigang
    Lei, Han
    He, Tong-Chuan
    Wang, Zhibiao
    Huang, Jing
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B224 - B224
  • [9] Noninvasive cardiac arrhythmia therapy using High-Intensity Focused Ultrasound (HIFU) ablation
    Wu, Qi
    Zhou, Qi
    Zhu, Que
    Rong, Shunkang
    Wang, Qi
    Guo, Rui
    Deng, Changming
    Liu, Dichuan
    Yang, Gang
    Jiang, Yonghong
    Wang, ZhiGang
    Lei, Han
    He, Tong-Chuan
    Wang, ZhiBiao
    Huang, Jing
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (02) : E28 - E30
  • [10] High-intensity focused ultrasound treatment for skin: ex vivo evaluation
    Park, J. -H.
    Lim, S. -D.
    Oh, S. H.
    Lee, J. H.
    Yeo, U. C.
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2017, 23 (03) : 384 - 391