Characterization and Ex Vivo evaluation of an extracorporeal high-intensity focused ultrasound (HIFU) system

被引:11
|
作者
Zhou, Yufeng [1 ]
Cunitz, Bryan W. [2 ]
Dunmire, Barbrina [2 ]
Wang, Yak-Nam [2 ]
Karl, Steven G. [2 ]
Warren, Cinderella [3 ]
Mitchell, Stuart [2 ]
Hwang, Joo Ha [2 ,3 ]
机构
[1] Northwestern Ploytech Univ, Sch Mech Engn, Xian, Peoples R China
[2] Univ Washington, Dept Med, Div Gastroenterol, Seattle, WA USA
[3] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
来源
关键词
acoustic nonlinearity; characterization; In-situ acoustic energy; high-intensity focused ultrasound; lesion; CANCER; TEMPERATURE; HYDROPHONE; LESIONS; FIELDS;
D O I
10.1002/acm2.13074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required. Methods The acoustic pressure and power output was characterized by a fiber optic probe and a radiation force balance, respectively, with the electrical power up to 2000 W. An in situ acoustic energy was established as the clinical protocol at the electrical power up to 500 W. Temperature elevation inside the tissue sample was measured by a thermocouple array. Generated lesion volume at different in situ acoustic energies and pathological examination of the lesions was evaluated ex vivo. Results Acoustic pressure mapping showed the insignificant presence of side/grating lobes and pre- or post-focal peaks (<=-12 dB). Although distorted acoustic pressure waveform was found in the free field, the nonlinearity was reduced significantly after the beam propagating through tissue samples (i.e., the second harmonic of -11.8 dB at 500 W). Temperature elevation was <10 degrees C at a distance of 10 mm away from a 20-mm target, which suggests the well-controlled HIFU energy deposition and no damage to the surrounding tissue. An acoustic energy in the range of 750-1250 J resulted in discrete lesions with an interval space of 5 mm between the treatment spots. Histology confirmed that the lesions represented a region of permanently damaged cells by heat fixation, without causing cell lysis by either cavitation or boiling. Conclusions Our characterization and ex vivo evaluation protocol met the IDE requirement. The in-situ acoustic energy model will be used in clinical trials to deliver almost consistent energy to the various targets.
引用
收藏
页码:345 / 359
页数:15
相关论文
共 50 条
  • [1] Influence of High-Intensity Focused Ultrasound (HIFU) Ablation on Arteries: Ex Vivo Studies
    Zhou, Yufeng
    Lim, Wei Chun Daniel
    [J]. MICROMACHINES, 2021, 12 (05)
  • [2] High-intensity focused ultrasound treatment for skin: ex vivo evaluation
    Park, J. -H.
    Lim, S. -D.
    Oh, S. H.
    Lee, J. H.
    Yeo, U. C.
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2017, 23 (03) : 384 - 391
  • [3] Transsclera Drug Delivery by Pulsed High-Intensity Focused Ultrasound (HIFU): An Ex Vivo Study
    Murugappan, Suresh Kanna
    Zhou, Yufeng
    [J]. CURRENT EYE RESEARCH, 2015, 40 (11) : 1172 - 1180
  • [4] Control parameters for high-intensity focused ultrasound (HIFU) for tissue ablation in the ex-vivo kidney
    Köhrmann, KU
    Michel, MS
    Steidler, A
    Marlinghaus, EH
    Kraut, O
    Alken, P
    [J]. AKTUELLE UROLOGIE, 2002, 33 (01) : 58 - 63
  • [5] Evaluation of High-Intensity Focused Ultrasound (HIFU) for Treatment of Localized Prostate Cancer
    Patel, Ronak
    Nahar, Bruno
    Bhat, Abhishek
    Becerra, Maria
    Madhusoodanan, Vinayak
    Jain, Anika
    Ritch, Chad
    Parekh, Dipen
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2020, 231 (04) : S337 - S337
  • [6] Ex vivo evaluation of high-intensity focused ultrasound with ultrasonic-induced cavitation bubbles
    Nobutaka Abe
    Hidekazu Nakamoto
    Takashi Suzuki
    Yoshihiro Muragaki
    Hiroshi Iseki
    [J]. Journal of Medical Ultrasonics, 2014, 41 : 3 - 9
  • [7] Ex vivo evaluation of high-intensity focused ultrasound with ultrasonic-induced cavitation bubbles
    Abe, Nobutaka
    Nakamoto, Hidekazu
    Suzuki, Takashi
    Muragaki, Yoshihiro
    Iseki, Hiroshi
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (01) : 3 - 9
  • [8] High-intensity focused ultrasound (HIFU) therapy for pancreatic cancer
    Asai, Yasutsugu
    Sofuni, Atsushi
    Itoi, Takao
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Kamada, Kentaro
    Tanaka, Reina
    Honjyou, Mitsuyoshi
    Mukai, Shuntaro
    Yamamoto, Kenjiro
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 261 - 261
  • [9] High-intensity focused ultrasound (HIFU) for localized prostate cancer
    Uchida, T
    Minei, S
    Satoh, T
    Shimura, S
    Irie, A
    Hyodo, T
    Omata, T
    Baba, S
    Narendra, ST
    Thomas, GA
    Michael, KO
    [J]. JOURNAL OF UROLOGY, 2002, 167 (04): : 358 - 358
  • [10] HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION OF EX VIVO BOVINE ACHILLES TENDON
    Muratore, Robert
    Akabas, Tal
    Muratore, Isabella B.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (12): : 2043 - 2050