Characterization and Ex Vivo evaluation of an extracorporeal high-intensity focused ultrasound (HIFU) system

被引:11
|
作者
Zhou, Yufeng [1 ]
Cunitz, Bryan W. [2 ]
Dunmire, Barbrina [2 ]
Wang, Yak-Nam [2 ]
Karl, Steven G. [2 ]
Warren, Cinderella [3 ]
Mitchell, Stuart [2 ]
Hwang, Joo Ha [2 ,3 ]
机构
[1] Northwestern Ploytech Univ, Sch Mech Engn, Xian, Peoples R China
[2] Univ Washington, Dept Med, Div Gastroenterol, Seattle, WA USA
[3] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
来源
关键词
acoustic nonlinearity; characterization; In-situ acoustic energy; high-intensity focused ultrasound; lesion; CANCER; TEMPERATURE; HYDROPHONE; LESIONS; FIELDS;
D O I
10.1002/acm2.13074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required. Methods The acoustic pressure and power output was characterized by a fiber optic probe and a radiation force balance, respectively, with the electrical power up to 2000 W. An in situ acoustic energy was established as the clinical protocol at the electrical power up to 500 W. Temperature elevation inside the tissue sample was measured by a thermocouple array. Generated lesion volume at different in situ acoustic energies and pathological examination of the lesions was evaluated ex vivo. Results Acoustic pressure mapping showed the insignificant presence of side/grating lobes and pre- or post-focal peaks (<=-12 dB). Although distorted acoustic pressure waveform was found in the free field, the nonlinearity was reduced significantly after the beam propagating through tissue samples (i.e., the second harmonic of -11.8 dB at 500 W). Temperature elevation was <10 degrees C at a distance of 10 mm away from a 20-mm target, which suggests the well-controlled HIFU energy deposition and no damage to the surrounding tissue. An acoustic energy in the range of 750-1250 J resulted in discrete lesions with an interval space of 5 mm between the treatment spots. Histology confirmed that the lesions represented a region of permanently damaged cells by heat fixation, without causing cell lysis by either cavitation or boiling. Conclusions Our characterization and ex vivo evaluation protocol met the IDE requirement. The in-situ acoustic energy model will be used in clinical trials to deliver almost consistent energy to the various targets.
引用
下载
收藏
页码:345 / 359
页数:15
相关论文
共 50 条
  • [31] Extracorporeal ablation of renal tumours with high-intensity focused ultrasound
    Marberger, M
    Schatzl, G
    Cranston, D
    Kennedy, JE
    BJU INTERNATIONAL, 2005, 95 : 52 - 55
  • [32] Extracorporeal ablation of uterine fibroids with high-intensity focused ultrasound
    Mahajan, Niraj N.
    Gaikwad, Nilima L.
    Soni, Rajani N.
    Mahajan, Kshitija N.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (05) : 702 - 702
  • [33] Ablation of renal tumours with extracorporeal high-intensity focused ultrasound
    Marberger, Michael
    BJU INTERNATIONAL, 2007, 99 (05) : 1273 - 1276
  • [34] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Khaldon Lweesy
    Luay Fraiwan
    Alaa Shatat
    Ghassan Abdo
    Abduallah Dawodiah
    Mohammad Sameer
    Medical & Biological Engineering & Computing, 2010, 48 : 269 - 276
  • [35] Numerical and Experimental Evaluation of High-Intensity Focused Ultrasound-Induced Lesions in Liver Tissue Ex Vivo
    Haddadi, Samaneh
    Ahmadian, Mohammad Taghi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (06) : 1481 - 1491
  • [36] High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity
    Marinova, Milka
    Rauch, Maximilian
    Muecke, Martin
    Rolke, Roman
    Gonzalez-Carmona, Maria A.
    Henseler, Jana
    Cuhls, Henning
    Radbruch, Lukas
    Strassburg, Christian P.
    Zhang, Lian
    Schild, Hans H.
    Strunk, Holger M.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 4047 - 4056
  • [37] Ultrasound-Guided High-Intensity Focused Ultrasound (HIFU) Treatment of Breast Fibroadenoma
    Kovatcheva, Roussanka
    Stoinov, Julian Ivanov
    Abehsera, Marc
    Seror, Bernard
    Guglielmina, Jean-Noel
    ANNALS OF SURGICAL ONCOLOGY, 2013, 20 : 52 - 52
  • [38] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Lweesy, Khaldon
    Fraiwan, Luay
    Shatat, Alaa
    Abdo, Ghassan
    Dawodiah, Abduallah
    Sameer, Mohammad
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (03) : 269 - 276
  • [39] High-intensity focused ultrasound (HIFU) for pancreatic carcinoma: evaluation of feasibility, reduction of tumour volume and pain intensity
    Milka Marinova
    Maximilian Rauch
    Martin Mücke
    Roman Rolke
    Maria A. Gonzalez-Carmona
    Jana Henseler
    Henning Cuhls
    Lukas Radbruch
    Christian P. Strassburg
    Lian Zhang
    Hans H. Schild
    Holger M. Strunk
    European Radiology, 2016, 26 : 4047 - 4056
  • [40] High-intensity focussed ultrasound (HIFU)
    Hunold, Peter
    Hoellen, F.
    Beldoch, M. P.
    Eckey, T.
    Bohlmann, M. K.
    GYNAKOLOGISCHE ENDOKRINOLOGIE, 2015, 13 (04): : 238 - 244