Characterization and Ex Vivo evaluation of an extracorporeal high-intensity focused ultrasound (HIFU) system

被引:11
|
作者
Zhou, Yufeng [1 ]
Cunitz, Bryan W. [2 ]
Dunmire, Barbrina [2 ]
Wang, Yak-Nam [2 ]
Karl, Steven G. [2 ]
Warren, Cinderella [3 ]
Mitchell, Stuart [2 ]
Hwang, Joo Ha [2 ,3 ]
机构
[1] Northwestern Ploytech Univ, Sch Mech Engn, Xian, Peoples R China
[2] Univ Washington, Dept Med, Div Gastroenterol, Seattle, WA USA
[3] Univ Washington, Appl Phys Lab, Ctr Ind & Med Ultrasound, Seattle, WA 98105 USA
来源
关键词
acoustic nonlinearity; characterization; In-situ acoustic energy; high-intensity focused ultrasound; lesion; CANCER; TEMPERATURE; HYDROPHONE; LESIONS; FIELDS;
D O I
10.1002/acm2.13074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background High-intensity focused ultrasound (HIFU) has been in clinical use for a variety of solid tumors and cancers. Accurate and reliable calibration is in a great need for clinical applications. An extracorporeal clinical HIFU system applied for the investigational device exemption (IDE) to the Food and Drug Administration (FDA) so that evaluation of its characteristics, performance, and safety was required. Methods The acoustic pressure and power output was characterized by a fiber optic probe and a radiation force balance, respectively, with the electrical power up to 2000 W. An in situ acoustic energy was established as the clinical protocol at the electrical power up to 500 W. Temperature elevation inside the tissue sample was measured by a thermocouple array. Generated lesion volume at different in situ acoustic energies and pathological examination of the lesions was evaluated ex vivo. Results Acoustic pressure mapping showed the insignificant presence of side/grating lobes and pre- or post-focal peaks (<=-12 dB). Although distorted acoustic pressure waveform was found in the free field, the nonlinearity was reduced significantly after the beam propagating through tissue samples (i.e., the second harmonic of -11.8 dB at 500 W). Temperature elevation was <10 degrees C at a distance of 10 mm away from a 20-mm target, which suggests the well-controlled HIFU energy deposition and no damage to the surrounding tissue. An acoustic energy in the range of 750-1250 J resulted in discrete lesions with an interval space of 5 mm between the treatment spots. Histology confirmed that the lesions represented a region of permanently damaged cells by heat fixation, without causing cell lysis by either cavitation or boiling. Conclusions Our characterization and ex vivo evaluation protocol met the IDE requirement. The in-situ acoustic energy model will be used in clinical trials to deliver almost consistent energy to the various targets.
引用
下载
收藏
页码:345 / 359
页数:15
相关论文
共 50 条
  • [21] The potential applications of high-intensity focused ultrasound (HIFU) in vascular neurosurgery
    Serrone, Joseph
    Kocaeli, Hasan
    Mast, T. Douglas
    Burgess, Mark T.
    Zuccarello, Mario
    JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (02) : 214 - 221
  • [22] High-Intensity Focused Ultrasound (HIFU) in Localized Prostate Cancer Treatment
    Alkhorayef, Mohammed
    Mahmoud, Mustafa Z.
    Alzimami, Khalid S.
    Sulieman, Abdelmoneim
    Fagiri, Maram A.
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 131 - 141
  • [23] Usefulness of High-Intensity Focused Ultrasound (HIFU) Therapy for Pancreatic Cancer
    Sofuni, Atsushi
    Moriyasu, Fuminori
    Sano, Takatomo
    Itokawa, Fumihide
    Tsuchiya, Takayoshi
    Ishii, Kentaro
    Tsuji, Shujiro
    Kurihara, Toshio
    Ikeuchi, Nobuhito
    Tanaka, Reina
    Umeda, Junko
    Tonozuka, Ryoske
    Honjo, Mitsuyoshi
    Itoi, Takao
    GASTROENTEROLOGY, 2013, 144 (05) : S213 - S214
  • [24] Fatal End of a Safety Algorithm for High-intensity Focused Ultrasound (HIFU)
    Neven, Kars
    Schmidt, Boris
    Metzner, Andreas
    Chun, K. R. Julian
    Ouyang, Feifan
    Kuck, Karl-Heinz
    CIRCULATION, 2009, 120 (18) : S659 - S659
  • [25] The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population
    R O Illing
    J E Kennedy
    F Wu
    G R ter Haar
    A S Protheroe
    P J Friend
    F V Gleeson
    D W Cranston
    R R Phillips
    M R Middleton
    British Journal of Cancer, 2005, 93 : 890 - 895
  • [26] High intensity focused ultrasound (HIFU)
    Barkin, Jack
    CANADIAN JOURNAL OF UROLOGY, 2011, 18 (02) : 5634 - 5643
  • [27] High intensity focused ultrasound (HIFU)
    Ganzer, R.
    RADIOLOGE, 2017, 57 (08): : 659 - 664
  • [28] Preliminary ex vivo feasibility study on targeted cell surgery by high intensity focused ultrasound (HIFU)
    Wang, Zhi Biao
    Wu, Junru
    Fang, Liao Qiong
    Wang, Hua
    Li, Fa Qi
    Tian, Yun Bo
    Gong, Xiao Bo
    Zhang, Hong
    Zhang, Lian
    Feng, Ruo
    ULTRASONICS, 2011, 51 (03) : 369 - 375
  • [29] The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population
    Illing, RO
    Kennedy, JE
    Wu, F
    ter Haar, GR
    Protheroe, AS
    Friend, PJ
    Gleeson, FV
    Cranston, DW
    Phillips, RR
    Middleton, MR
    BRITISH JOURNAL OF CANCER, 2005, 93 (08) : 890 - 895
  • [30] In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode
    Dai, Hongya
    Chen, Fei
    Yan, Sijing
    Ding, Xiaoya
    Ma, Dazhao
    Wen, Jing
    Xu, Die
    Zou, Jianzhong
    MEDICAL SCIENCE MONITOR, 2017, 23 : 3373 - 3382