Comparison of Endothelial Barrier Functional Recovery After Implantation of a Novel Biodegradable-Polymer Sirolimus-Eluting Stent in Comparison to Durable- and Biodegradable-Polymer Everolimus-Eluting Stents

被引:10
|
作者
Sakamoto, Atsushi [1 ]
Torii, Sho [1 ]
Jinnouchi, Hiroyuki [1 ]
Guo, Liang [1 ]
Cornelissen, Anne [1 ]
Kuntz, Salome [1 ]
Cheng, Qi [1 ]
Fernandez, Raquel [1 ]
Paek, Ka Hyun [1 ]
Harris, Kathryn [2 ]
Srivastava, Mukta C. [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
Finn, Aloke, V [1 ,2 ]
机构
[1] CVPath Inst Inc, 19 Firstfield Rd, Gaithersburg, MD 20878 USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
Drug eluting stent; Biodegradable polymer; Durable polymer; Endothelial function; Vascular permeability;
D O I
10.1016/j.carrev.2020.08.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The advantage of biodegradable-polymer drug-eluting stents (BP-DES) versus durable-polymer (DP) DES remains uncertain. We compared neointimal formation and endothelial barrier function of new BP sirolimus-eluting stents (BP-SES, BuMA Supreme (R)) to other contemporary BP-DES, DP-DES, and bare metal stents (BMS). Methods and results: Light microscopic assessment in swine coronary arteries showed comparable neointimal formation between BP-SES and DP everolimus-eluting stent (DP-EES). The performance of BP-SES was compared with DP-EES (Xience Xpedition (R)), BP-EES (Synergy (R)), and BMS (Multi-Link Vision (R)) at 45- and 90-days in rabbit ilio-femoral arteries using Evans blue dye (EBD) followed by immunostaining for endothelial barrier proteins (p120/vascular endothelial-cadherin [VE-cad]) to evaluate endothelial barrier function and scanning electron microscopy (SEM) to determine strut tissue coverage. BMS followed by BP-SES and BP-EES exhibited smaller EBD positive areas versus that of DP-EES at 45- and 90-days. p120/VE-cad immunostaining and SEM-determined strut coverage was greater at 45- and 90-days for BMS followed by all DESs. Regardless of stent type, the lack of p120/VE-cad co-localization showed greater leukocyte and platelet aggregation. Conclusion: Three types of DES showed different endothelial healing pattern regardless their equivalent suppression of neointimal formation. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent 5-Year Outcomes of the Randomized BIOFLOW-II Trial
    Lefevre, Thierry
    Haude, Michael
    Neumann, Franz-Josef
    Stangl, Karl
    Skurk, Carsten
    Slagboom, Ton
    Sabate, Manel
    Goicolea, Javier
    Barragan, Paul
    Cook, Stephane
    Macia, Jean-Christophe
    Windecker, Stephan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (10) : 995 - 1002
  • [22] Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial
    Pilgrim, Thomas
    Roffi, Marco
    Tueller, David
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Heg, Dik
    Jueni, Peter
    Windecker, Stephan
    AMERICAN HEART JOURNAL, 2014, 168 (03) : 256 - 261
  • [23] DIFFERENTIAL VASCULAR HEALING PATTERNS WITH RAPID ABSORPTION BIODEGRADABLE POLYMER SIROLIMUS-ELUTING STENTS VERSUS DURABLE POLYMER EVEROLIMUS-ELUTING STENTS
    Tada, Tomohisa
    Byrne, Robert
    Cuni, Rezarta
    King, Lamin
    Joner, Michael
    Schomig, Albert
    Kastrati, Adnan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E316 - E316
  • [24] Unselected use of ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for coronary revascularization
    Yamaji, Kyohei
    Zanchin, Thomas
    Zanchin, Christian
    Stortecky, Stefan
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raber, Lorenz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B265 - B266
  • [25] Unselected Use of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Coronary Revascularization
    Yamaji, Kyohei
    Zanchin, Thomas
    Zanchin, Christian
    Stortecky, Stefan
    Koskinas, Konstantinos C.
    Hunziker, Lukas
    Praz, Fabien
    Bloechlinger, Stefan
    Moro, Christina
    Moschovitis, Aris
    Seiler, Christian
    Valgimigli, Marco
    Billinger, Michael
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raeber, Lorenz
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (09)
  • [26] Comparison between a novel bioabsorbable polymer everolimus-eluting stent and a durable polymer everolimus-eluting stent
    Tsutsumi, M.
    Ito, Y.
    Hirano, K.
    Yamawaki, M.
    Araki, M.
    Kobayashi, N.
    Mori, S.
    Sakamoto, Y.
    Honda, Y.
    Tokuda, T.
    Makino, K.
    Shirai, S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 135 - 135
  • [27] Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents
    Kandzari, David E.
    Koolen, Jacques J.
    Doros, Gheorghe
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (18) : 1852 - 1860
  • [28] Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction
    Pilgrim, Thomas
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Vuilliomenet, Andre
    Muller, Olivier
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Khattab, Ahmed A.
    Taniwaki, Masanori
    Rigamonti, Fabio
    Nietlispach, Fabian
    Blochlinger, Stefan
    Wenaweser, Peter
    Juni, Peter
    Windecker, Stephan
    EUROINTERVENTION, 2016, 12 (11) : E1343 - E1354
  • [29] Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations
    Costopoulos, Charis
    Latib, Azeem
    Naganuma, Toru
    Sticchi, Alessandro
    Ferrarello, Santo
    Regazzoli, Damiano
    Chieffo, Alaide
    Figini, Filippo
    Carlino, Mauro
    Montorfano, Matteo
    Naim, Charbel
    Kawaguchi, Masanori
    Gerasimou, Argyrios
    Giannini, Francesco
    Godino, Cosmo
    Colombo, Antonio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (06) : 889 - 895
  • [30] Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents
    Kandzari, David E.
    Koolen, Jacques J.
    Doros, Gheorghe
    Massaro, Joseph J.
    Garcia-Garcia, Hector M.
    Bennett, Johan
    Roguin, Ariel
    Gharib, Elie G.
    Cutlip, Donald E.
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (25) : 3287 - 3297