Comparison of Endothelial Barrier Functional Recovery After Implantation of a Novel Biodegradable-Polymer Sirolimus-Eluting Stent in Comparison to Durable- and Biodegradable-Polymer Everolimus-Eluting Stents

被引:10
|
作者
Sakamoto, Atsushi [1 ]
Torii, Sho [1 ]
Jinnouchi, Hiroyuki [1 ]
Guo, Liang [1 ]
Cornelissen, Anne [1 ]
Kuntz, Salome [1 ]
Cheng, Qi [1 ]
Fernandez, Raquel [1 ]
Paek, Ka Hyun [1 ]
Harris, Kathryn [2 ]
Srivastava, Mukta C. [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
Finn, Aloke, V [1 ,2 ]
机构
[1] CVPath Inst Inc, 19 Firstfield Rd, Gaithersburg, MD 20878 USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
Drug eluting stent; Biodegradable polymer; Durable polymer; Endothelial function; Vascular permeability;
D O I
10.1016/j.carrev.2020.08.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The advantage of biodegradable-polymer drug-eluting stents (BP-DES) versus durable-polymer (DP) DES remains uncertain. We compared neointimal formation and endothelial barrier function of new BP sirolimus-eluting stents (BP-SES, BuMA Supreme (R)) to other contemporary BP-DES, DP-DES, and bare metal stents (BMS). Methods and results: Light microscopic assessment in swine coronary arteries showed comparable neointimal formation between BP-SES and DP everolimus-eluting stent (DP-EES). The performance of BP-SES was compared with DP-EES (Xience Xpedition (R)), BP-EES (Synergy (R)), and BMS (Multi-Link Vision (R)) at 45- and 90-days in rabbit ilio-femoral arteries using Evans blue dye (EBD) followed by immunostaining for endothelial barrier proteins (p120/vascular endothelial-cadherin [VE-cad]) to evaluate endothelial barrier function and scanning electron microscopy (SEM) to determine strut tissue coverage. BMS followed by BP-SES and BP-EES exhibited smaller EBD positive areas versus that of DP-EES at 45- and 90-days. p120/VE-cad immunostaining and SEM-determined strut coverage was greater at 45- and 90-days for BMS followed by all DESs. Regardless of stent type, the lack of p120/VE-cad co-localization showed greater leukocyte and platelet aggregation. Conclusion: Three types of DES showed different endothelial healing pattern regardless their equivalent suppression of neointimal formation. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial
    Gao, Run-Lin
    Xu, Bo
    Lansky, Alexandra J.
    Yang, Yue-Jin
    Ma, Chang-Sheng
    Han, Ya-Ling
    Chen, Shao-Liang
    Li, Hui
    Zhang, Rui-Yan
    Fu, Guo-Sheng
    Yuan, Zu-Yi
    Jiang, Hong
    Huo, Yong
    Li, Wei
    Zhang, Yao-Jun
    Leon, Martin B.
    EUROINTERVENTION, 2013, 9 (01) : 75 - 83
  • [42] NOBORI™ biodegradable-polymer biolimus-eluting stent versus durable-polymer drug-eluting stents: A meta-analysis
    Zhang, Yao-Jun
    Ye, Fei
    Iqbal, Javaid
    Dong, Sheng-Jie
    Bourantas, Christos V.
    Tian, Nai-Liang
    Serruys, Patrick W.
    Chen, Shao-Liang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (01) : 151 - 153
  • [43] Everolimus-Eluting Biodegradable Polymer Versus Everolimus-Eluting Durable Polymer Stent for Coronary Revascularization in Routine Clinical Practice
    Zanchin, Christian
    Ueki, Yasushi
    Zanchin, Thomas
    Haner, Jonas
    Otsuka, Tatsuhiko
    Stortecky, Stefan
    Koskinas, Konstantinos C.
    Siontis, George C. M.
    Praz, Fabien
    Moschovitis, Aris
    Hunziker, Lukas
    Valgimigli, Marco
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raber, Lorenz
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (17) : 1665 - 1675
  • [44] Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography
    Tada, Tomohisa
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    Kitabata, Hironori
    Tiroch, Klaus
    Dirninger, Alfred
    Gratze, Franz
    Kaspar, Klaus
    Zenker, Gerald
    Joner, Michael
    Schomig, Albert
    Kastrati, Adnan
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2013, 14 (02) : 84 - 89
  • [45] Acute Thrombogenicity and Inflammation in Response to a Durable Fluoropolymer Everolimus-Eluting Stent Relative to a Contemporary Sirolimus-Eluting Stent with an Abluminal Biodegradable Polymer Coating
    Torii, Sho
    Cheng, Qi
    Kolodgie, Frank
    Acampado, Eduardo
    Yahagi, Kazuyuki
    Mori, Hiroyoshi
    Romero, Maria
    Perkins, Laura
    Hossainy, Syed
    Pacetti, Stephen
    Finn, Aloke
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B188 - B188
  • [46] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Akito Kawamura
    Yasuyuki Egami
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Hitoshi Nakamura
    Yutaka Matsuhiro
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Masami Nishino
    Jun Tanouchi
    Cardiovascular Intervention and Therapeutics, 2022, 37 : 681 - 690
  • [48] Preferable vascular healing of ultrathin strut biodegradable-polymer sirolimus-eluting stents in patients with acute coronary syndrome
    Kawamura, Akito
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Nishino, Masami
    Tanouchi, Jun
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 681 - 690
  • [49] Efficacy and safety of domestic biodegradable polymer sirolimus-eluting stents and durable polymer sirolimus-eluting stents in the treatment of coronary artery disease
    Fang, Yi
    Bin, Wang
    Jing, Li
    Qiu Miaohan
    Han Yaling
    Shuang, Wang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C106 - C107
  • [50] Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study
    Parsa, Ehsan
    Saroukhani, Sepideh
    Majlessi, Fereshteh
    Poorhosseini, Hamidreza
    Lofti-Tokaldany, Masoumeh
    Jalali, Arash
    Salarifar, Mojtaba
    Nematipour, Ebrahim
    Alidoosti, Mohammad
    Aghajani, Hassan
    Amirzadegan, Alireza
    Kassaian, Seyed Ebrahim
    TEXAS HEART INSTITUTE JOURNAL, 2016, 43 (02): : 126 - 130