Numerical investigation on stress intensity around Bone-Implant interface by 3-Dimensional FEA and experimental verification by optical technique

被引:12
|
作者
Dhatrak, Pankaj [1 ]
Shirsat, Uddhav [2 ]
Sumanth, S. [3 ]
Deshmukh, Vijay [4 ]
机构
[1] Dr Vishwanath Karad MIT WPU, MAEERS MIT, Sch Mech Engn, Pune 38, Maharashtra, India
[2] Bhivarabai Swanat Coll Engn & Researach, Dept Mech Engn, Pune 41, Maharashtra, India
[3] MA Rangoonwal Coll Dent Sci & Res Ctr, Dept Periodont, Pune 01, Maharashtra, India
[4] Int Clin Dent Res Org, Pune 38, Maharashtra, India
关键词
Cancellous bone; Dental Implant; FEA; Optical Technique; Photoelastic stress;
D O I
10.1016/j.matpr.2020.06.097
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of the current study is to examine numerically the stress intensity along bone-implant interface for selected implant systems under occlusal load using finite element analysis (FEA) and confirming the result experimentally by optical technique. To see the biomechanical performance at bone-implant interface the five types of implant systems are chosen for the current study. A three-dimensional (3D) computer aided design (CAD) is prepared using CreO Parametric modeling software. A non-linear contact between implant and surrounding bone is defined to analyze the stress intensity in the cancellous bone under the applied load of 100 N axial directions, 40 N laterals (Bucco-lingual) direction and 100 N oblique at 45 degree to the longitudinal axis of implant. An experimental photoelastic technique (Optical technique) is used to predict the stress intensity in a cancellous bone near the bone-implant interface using Tardy's method of compensation. A homogeneous blend of Araldite and hardener material is used to prepare a photoelastic block model. The maximum value of stress intensity is noted in Type-I implant system at apical part of implant whereas minimum value was noted in Type-III implant systemunder lateral and oblique loads. Stress intensity in cancellous bone at the bone interface is found to be more significant to the applied oblique load. (C) 2020 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [11] THE 3-DIMENSIONAL BONE INTERFACE OF AN OSSEOINTEGRATED IMPLANT - A METHOD FOR STUDY
    AKAGAWA, Y
    WADAMOTO, M
    SATO, Y
    TSURU, H
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (05): : 813 - 816
  • [12] Stress and Strain Analysis of the Bone-Implant Interface: A Comparison of Fiber-Reinforced Composite and Titanium Implants Utilizing 3-Dimensional Finite Element Study
    Shinya, Akikazu
    Ballo, Ahmed M.
    Lassila, Lippo V. J.
    Shinya, Akiyoshi
    Narhi, Timo O.
    Vallittu, Pekka K.
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 : 133 - 140
  • [13] Reflection of an ultrasonic wave on the bone-implant interface: Comparison of two-dimensional and three-dimensional numerical models
    Heriveaux, Yoann
    Haiat, Guillaume
    Vu-Hieu Nguyen
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (01): : EL32 - EL36
  • [14] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF A PROPELLER WITH 3-DIMENSIONAL INFLOW
    SCHETZ, JA
    PELLETIER, D
    MALLORY, DA
    JOURNAL OF PROPULSION AND POWER, 1988, 4 (04) : 341 - 349
  • [15] Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography
    Choi, Jung-Yoo Chesaria
    Choi, Cham Albert
    Yeo, In-Sung Luke
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (04): : 202 - 212
  • [16] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [17] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF THE 3-DIMENSIONAL TRANSITION IN PLANE WAKES
    MEIBURG, E
    LASHERAS, JC
    JOURNAL OF FLUID MECHANICS, 1988, 190 : 1 - 37
  • [18] NUMERICAL AND EXPERIMENTAL INVESTIGATION OF 3-DIMENSIONAL FLOW IN EXTRUSION DIES
    GUPTA, M
    JALURIA, Y
    SERNAS, V
    ESSEGHIR, M
    KWON, TH
    POLYMER ENGINEERING AND SCIENCE, 1993, 33 (07): : 393 - 399
  • [19] NUMERICAL INVESTIGATION OF THE INTERFACE TENSION IN THE 3-DIMENSIONAL ISING-MODEL
    KLESSINGER, S
    MUNSTER, G
    NUCLEAR PHYSICS B, 1992, 386 (03) : 701 - 713
  • [20] Effect of vertical bone loss on stress distribution at the bone-implant interface around implants of varying diameters-an in silico 3D finite element analysis
    Gupta, Shipra
    Chopra, Priyanka
    Goyal, Parveen
    Jain, Ashish
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 4581 - 4586