THE 3-DIMENSIONAL BONE INTERFACE OF AN OSSEOINTEGRATED IMPLANT - A METHOD FOR STUDY

被引:21
|
作者
AKAGAWA, Y
WADAMOTO, M
SATO, Y
TSURU, H
机构
[1] Hiroshima University School of Dentistry, Hiroshima
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1992年 / 68卷 / 05期
关键词
D O I
10.1016/0022-3913(92)90208-R
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To clarify the three-dimensional bone structure around a plasma-sprayed hydroxyapatite-coated endosseous dental implant, bone contact with the implant at 75 mum intervals was evaluated. Based on digitized data, three-dimensional graphics of the bone around the implant was clearly shown. These graphics provide adequate information on the bone-implant interface and also suggest development of a realistic finite element model.
引用
收藏
页码:813 / 816
页数:4
相关论文
共 50 条
  • [1] Micromechanical modeling of the contact stiffness of an osseointegrated bone–implant interface
    Maria Letizia Raffa
    Vu-Hieu Nguyen
    Guillaume Haiat
    BioMedical Engineering OnLine, 18
  • [2] COMPUTERIZED 3-DIMENSIONAL ANALYSIS OF BONE-STRUCTURE AROUND OSSEOINTEGRATED IMPLANTS
    WADAMOTO, M
    AKAGAWA, Y
    SATO, Y
    HASHIMOTO, M
    SAGARA, M
    KOMURA, I
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 330 - 330
  • [3] A study of force distribution of loading stresses on implant-bone interface on short implant length using 3-dimensional finite element analysis
    Kang, Ning
    Wu, Yan-yun
    Gong, Ping
    Yue, Li
    Ou, Guo-min
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 118 (05): : 519 - 523
  • [4] The three-dimensional bone interface of an osseointegrated implant .1. A morphometric evaluation in initial healing
    Wadamoto, M
    Akagawa, Y
    Sato, Y
    Kubo, T
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02): : 170 - 175
  • [5] Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface
    Raffa, Maria Letizia
    Vu-Hieu Nguyen
    Haiat, Guillaume
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (01)
  • [6] The Impact of Bone Compression on Bone-to-Implant Contact of an Osseointegrated Implant: A Canine Study
    Nevins, Myron
    Nevins, Marc L.
    Schupbach, Peter
    Fiorellini, Joseph
    Lin, Zhao
    Kim, David M.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2012, 32 (06) : 637 - 646
  • [7] STUDY OF A 3-DIMENSIONAL CRACK TERMINATING AT AN INTERFACE
    LEE, JC
    KEER, LM
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1986, 53 (02): : 311 - 316
  • [8] Imaging of Osseointegrated Implants in the Temporal Bone by Accuitomo 3-Dimensional Cone Beam Computed Tomography
    Granstrom, Gosta
    Grondahl, Hans-Goran
    OTOLOGY & NEUROTOLOGY, 2011, 32 (02) : 199 - 203
  • [9] The three-dimensional bone interface of an osseointegrated implant .2. A morphometric evaluation after three months of loading
    Sahin, S
    Akagawa, Y
    Wadamoto, M
    Sato, Y
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02): : 176 - 180
  • [10] Influence of location of osseointegrated implant on stress distribution in implant supported longitudinal removable partial dentures: 3-dimensional finite element analysis
    Liu, Yang
    Zhang, Yi-Nan
    Sasaki, Keiichi
    Chen, Xiao-Dong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 10399 - 10410