Calibration of an industrial pulsed field magnetometer

被引:10
|
作者
Grössinger, R [1 ]
Taraba, M
Wimmer, A
Dudding, J
Cornelius, R
Knell, R
Bissel, P
Enzberg-Mahlke, B
Fernengel, W
Toussaint, JC
Edwards, D
机构
[1] Vienna Univ Technol, Inst Festkorperphys, A-1040 Vienna, Austria
[2] Univ Cent Lancashire, Preston PR1 2HE, Lancs, England
[3] Magnetfabrik Schramberg, D-78713 Schramberg Sulgen, Germany
[4] VACUUMSCHMELZE, D-63450 Hanau, Germany
[5] CNRS, F-38042 Grenoble, France
[6] Mecelec Dev Ltd, Gloucester GL2 5QT, England
关键词
magnetometer; permanent magnets; pulsed fields;
D O I
10.1109/TMAG.2002.803199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An industrial design of a pulsed field magnetometer (PFM) which generates in a bore of 30 nun a maximum field of 5 tesla with two different pulse durations (40 and 57 ms) is described. The field is calibrated using a small pickup coil where the effective winding area is known from a nuclear magnetic resonance calibration. The magnetization is calibrated using Fe3O4, an industrial ferrite, but also Fe and Ni.
引用
收藏
页码:2982 / 2984
页数:3
相关论文
共 50 条
  • [31] Calibration and Error Compensation of Magnetometer
    Liu, Zhiping
    Zhu, Mingjing
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4122 - 4126
  • [32] Calibration of the Ørsted vector magnetometer
    Nils Olsen
    Lars Tøffner-Clausen
    Terence J. Sabaka
    Peter Brauer
    Jose M. G. Merayo
    John L. Jørgensen
    J. M. Léger
    Otto V. Nielsen
    Fritz Primdahl
    Torben Risbo
    Earth, Planets and Space, 2003, 55 : 11 - 18
  • [33] Gyroscope Calibration via Magnetometer
    Wu, Yuanxin
    Pei, Ling
    IEEE SENSORS JOURNAL, 2017, 17 (16) : 5269 - 5275
  • [34] Pulsed inductive microwave magnetometer
    Kos, AB
    Silva, TJ
    Kabos, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (10): : 3563 - 3569
  • [35] Online Magnetometer Calibration in Indoor Environments for Magnetic field-based SLAM
    Coulin, Jade
    Guillemard, Richard
    Gay-Bellile, Vincent
    Joly, Cyril
    De la Fortelle, Arnaud
    2022 IEEE 12TH INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION (IPIN 2022), 2022,
  • [36] HELIUM MAGNETOMETER WITH A PULSED PUMP
    YAKOBSON, NN
    ALEKSANDROV, EB
    ZHURNAL TEKHNICHESKOI FIZIKI, 1978, 48 (09): : 1914 - 1919
  • [37] PULSED-FIELD MAGNETOMETER FOR NONDESTRUCTIVE MONITORING OF ENCAPSULATED MAGNETIC-MATERIALS
    ROTHWARF, F
    SIMIZU, S
    HUANG, MQ
    SCHAEFER, RJ
    JOURNAL OF APPLIED PHYSICS, 1993, 73 (10) : 5614 - 5616
  • [38] Pulsed vector atomic magnetometer using an alternating fast-rotating field
    Wang, Tao
    Lee, Wonjae
    Limes, Mark
    Kornack, Thomas
    Foley, Elizabeth
    Romalis, Michael
    NATURE COMMUNICATIONS, 2025, 16 (01)
  • [39] CALIBRATION CHARACTERISTICS OF PULSED-FIELD ELECTROMAGNETIC FLOWMETER
    BECK, R
    MORRIS, JA
    ASSALI, NS
    AMERICAN JOURNAL OF MEDICAL ELECTRONICS, 1965, 4 (02): : 87 - &
  • [40] Field Sensor Bias Calibration With Angular-Rate Sensors: Theory and Experimental Evaluation With Application to Magnetometer Calibration
    Troni, Giancarlo
    Whitcomb, Louis L.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (04) : 1698 - 1710