Calibration of an industrial pulsed field magnetometer

被引:10
|
作者
Grössinger, R [1 ]
Taraba, M
Wimmer, A
Dudding, J
Cornelius, R
Knell, R
Bissel, P
Enzberg-Mahlke, B
Fernengel, W
Toussaint, JC
Edwards, D
机构
[1] Vienna Univ Technol, Inst Festkorperphys, A-1040 Vienna, Austria
[2] Univ Cent Lancashire, Preston PR1 2HE, Lancs, England
[3] Magnetfabrik Schramberg, D-78713 Schramberg Sulgen, Germany
[4] VACUUMSCHMELZE, D-63450 Hanau, Germany
[5] CNRS, F-38042 Grenoble, France
[6] Mecelec Dev Ltd, Gloucester GL2 5QT, England
关键词
magnetometer; permanent magnets; pulsed fields;
D O I
10.1109/TMAG.2002.803199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An industrial design of a pulsed field magnetometer (PFM) which generates in a bore of 30 nun a maximum field of 5 tesla with two different pulse durations (40 and 57 ms) is described. The field is calibrated using a small pickup coil where the effective winding area is known from a nuclear magnetic resonance calibration. The magnetization is calibrated using Fe3O4, an industrial ferrite, but also Fe and Ni.
引用
收藏
页码:2982 / 2984
页数:3
相关论文
共 50 条
  • [21] Improvement of Formula and Uncertainty of the Reference Magnetic Field for AC Magnetometer Calibration
    Ishii, Masanori
    Ketzler, Rainer
    Albrecht, Martin
    Kurokawa, Satoru
    Shimada, Yozo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1443 - 1449
  • [22] Statistical Analysis of In-Field Magnetometer Calibration for Two Representative Methods
    Yu, Hairong
    Guo, Ying
    Ye, Lin
    Su, Steven Weidong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [23] Multiprobe magnetometer for analysis of local field distortions induced by pulsed gradients
    Lab de Resonance Magnetique, Nucleaire, Villeurbanne, France
    Meas Sci Technol, 3 (332-337):
  • [24] Springback calibration using pulsed electromagnetic field
    Golovashchenko, SF
    NUMISHEET 2005: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE AND WORKSHOP ON NUMERICAL SIMULATION OF 3D SHEET METAL FORMING PROCESSES, PTS A AND B, 2005, 778 : 284 - 285
  • [25] A multiprobe magnetometer for analysis of local field distortions induced by pulsed gradients
    Chaabane, L
    Favre, B
    Desgoutte, P
    Deguin, A
    Lapray, C
    Briguet, A
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (03) : 332 - 337
  • [26] Shipboard Vector Magnetometer Calibration
    Frontera, Paul J.
    Alessandrini, Stephen M.
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 211 - 218
  • [27] CALIBRATION OF AC INDUCTION MAGNETOMETER
    Koprivica, Branko
    Sucurovic, Marko
    Milovanovic, Alenka
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2018, 31 (04) : 613 - 626
  • [28] Calibration of the Orsted vector magnetometer
    Olsen, N
    Toffner-Clausen, L
    Sabaka, TJ
    Brauer, P
    Merayo, JMG
    Jorgensen, JL
    Léger, JM
    Nielsen, OV
    Primdahl, F
    Risbo, T
    EARTH PLANETS AND SPACE, 2003, 55 (01): : 11 - 18
  • [29] Explicit Solution for Magnetometer Calibration
    Hemerly, Elder M.
    Coelho, Fernando A. A.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (08) : 2093 - 2095
  • [30] ABSOLUTE CALIBRATION OF A SPINNING MAGNETOMETER
    ROBERTSON, DJ
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (05): : 393 - 394