Calibration of an industrial pulsed field magnetometer

被引:10
|
作者
Grössinger, R [1 ]
Taraba, M
Wimmer, A
Dudding, J
Cornelius, R
Knell, R
Bissel, P
Enzberg-Mahlke, B
Fernengel, W
Toussaint, JC
Edwards, D
机构
[1] Vienna Univ Technol, Inst Festkorperphys, A-1040 Vienna, Austria
[2] Univ Cent Lancashire, Preston PR1 2HE, Lancs, England
[3] Magnetfabrik Schramberg, D-78713 Schramberg Sulgen, Germany
[4] VACUUMSCHMELZE, D-63450 Hanau, Germany
[5] CNRS, F-38042 Grenoble, France
[6] Mecelec Dev Ltd, Gloucester GL2 5QT, England
关键词
magnetometer; permanent magnets; pulsed fields;
D O I
10.1109/TMAG.2002.803199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An industrial design of a pulsed field magnetometer (PFM) which generates in a bore of 30 nun a maximum field of 5 tesla with two different pulse durations (40 and 57 ms) is described. The field is calibrated using a small pickup coil where the effective winding area is known from a nuclear magnetic resonance calibration. The magnetization is calibrated using Fe3O4, an industrial ferrite, but also Fe and Ni.
引用
收藏
页码:2982 / 2984
页数:3
相关论文
共 50 条
  • [1] Pulsed field magnetometer for industrial use
    Cornelius, R
    Dudding, J
    Knell, P
    Grossinger, R
    Enzberg-Mahlke, B
    Fernengel, W
    Küpferling, M
    Taraba, M
    Toussaint, JC
    Wimmer, A
    Edwards, D
    IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (05) : 2462 - 2464
  • [2] Hysteresis measurements on industrial permanent magnets in a pulsed field magnetometer
    Grössinger, R
    Taraba, M
    Wimmer, A
    Dudding, J
    Cornelius, R
    Knell, P
    Enzberg-Mahlke, B
    Fernengel, W
    Toussaint, JC
    Edwards, D
    RARE EARTH MAGNETS AND THEIR APPLICATIONS, 2002, : 285 - 292
  • [3] A volt-second source for calibration of integrator in a pulsed field magnetometer
    Lin An-Li
    He Jian
    Zhang Yue
    John Dudding
    Michael Hall
    CHINESE PHYSICS LETTERS, 2007, 24 (11) : 3088 - 3091
  • [4] Design of a 20 T Pulsed Magnet for the Pulsed Field Magnetometer
    Chen, Jinqiao
    Wang, Shuang
    Peng, Tao
    Li, Liang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) : 1 - 5
  • [5] Calibration of Magnetometer Arrays in Magnetic Field Gradients
    Mu, Yaxin
    Zhang, Xiaojuan
    Xie, Wupeng
    IEEE MAGNETICS LETTERS, 2019, 10
  • [6] Development of pulsed field magnetometer with flexible structure
    Hu, Heng
    Shu, Chengzhe
    Chen, Jinqiao
    Peng, Tao
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2021, 538
  • [7] CALIBRATION OF PULSED MAGNETIC FIELD
    IMAMURA, N
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1968, 7 (08) : 958 - &
  • [8] Localization With Magnetic Field Distortions and Simultaneous Magnetometer Calibration
    Siebler, Benjamin
    Sand, Stephan
    Hanebeck, Uwe D.
    IEEE SENSORS JOURNAL, 2021, 21 (03) : 3388 - 3397
  • [9] Recommended Tolerances for Magnetometer Orientation and Field Calibration Procedure
    Ernst, Joseph M.
    Ault, Aaron
    Krogmeier, James V.
    Bullock, Darcy M.
    TRANSPORTATION RESEARCH RECORD, 2009, (2128) : 66 - 75
  • [10] A pulsed field magnetometer for the quality control of permanent magnets
    Dudding, J
    Knell, PA
    Cornelius, RN
    Enzberg-Mahlke, B
    Fernengel, W
    Grössinger, R
    Küpferling, M
    Lethuillier, P
    Reyne, G
    Taraba, M
    Toussaint, JC
    Wimmer, A
    Edwards, D
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2002, 242 : 1402 - 1404