Bacterial Colonization of the Implant-Abutment Interface (IAI) of Dental Implants with a Sloped Marginal Design: An in-vitro Study

被引:30
|
作者
Koutouzis, Theofilos [1 ]
Gadalla, Hana [2 ]
Lundgren, Tord [3 ]
机构
[1] Nova SE Univ, Coll Dent Med, Dept Periodontol, 3200 South Univ Dr, Ft Lauderdale, FL 33327 USA
[2] Univ Detroit Mercy, Sch Dent, Dept Periodontol, Detroit, MI 48221 USA
[3] King Faisal Specialist Hosp & Res Ctr, Dept Dent, Jeddah, Saudi Arabia
关键词
bacterial counts; bacterial leakage; dental implants; in vitro; titanium; FIXED PARTIAL DENTURES; CRESTAL BONE CHANGES; SUBMERGED IMPLANTS; INTERNAL SURFACES; ALVEOLAR RIDGE; LEVEL CHANGES; MICROGAP; INFLAMMATION; LEAKAGE; PART;
D O I
10.1111/cid.12287
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this study is to utilize an in vitro dynamic loading model to assess the potential risk of bacterial invasion into the Implant Abutment Interface (IAI) microgap of dental implants with sloped marginal design. Materials and MethodsForty implants were divided into two groups (n=20 per group) based on implant marginal design. Group 1 was comprised of implants with Morse-taper connection and conventional marginal design that connected to titanium abutments. Group 2 was comprised of implants with Morse-taper connection and sloped marginal design that connected to titanium abutments. The specimens were immersed in a bacterial solution of E.coli and loaded with 500,000 cycles of 160N using a chewing simulator. Following disconnection of fixtures and abutments, microbial samples were taken from the threaded portion of the abutment, plated and cultured under appropriate conditions. ResultsTen out of twenty implants of Group 1 and eight out of twenty implants of Group 2 had IAI microgaps colonized by E.Coli. There was not a statistically significant difference in the mean number of E.ColiCFU detected between implants of Group 1 (mean 19.2, SD 23.6) and Group 2 (mean 12.5, SD18.9) (p>.05). ConclusionsThe present study demonstrated that implants with a sloped marginal design exhibited similar risk for bacterial invasion into the IAI microgap under in vitro dynamic loading conditions compared to implants with conventional marginal design.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 50 条
  • [31] Mechanical Outcomes, Microleakage, and Marginal Accuracy at the Implant-Abutment Interface of Original versus Nonoriginal Implant Abutments: A Systematic Review of In Vitro Studies
    Tallarico, Marco
    Fiorellini, Joseph
    Nakajima, Yasushi
    Omori, Yuki
    Takahisa, Iida
    Canullo, Luigi
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [32] PREVENTION OF BACTERIAL LEAKAGE AT IMPLANT-ABUTMENT CONNECTION LEVEL: AN IN VITRO STUDY OF THE EFFICACY OF THREE DIFFERENT IMPLANT SYSTEMS
    Carinci, F.
    Lauritano, D.
    Cura, F.
    Lopez, M. A.
    Bassi, M. Andreasi
    Confalone, L.
    Pezzetti, F.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2016, 30 (02): : 69 - 73
  • [33] In vitro study of the correlation between the simulated clinical and radiographic examination of microgaps at the implant-abutment interface
    Konermann, Anna C.
    Zoellner, Axel
    Chang, Brian M.
    Wright, Robert F.
    QUINTESSENCE INTERNATIONAL, 2010, 41 (08): : 681 - 687
  • [34] Effect of Repeated Moist Heat Sterilization on Titanium Implant-Abutment Interface-An In Vitro Study
    Morsy, Mohamed S. M.
    Hassan, Ali Abdel-Halim Abdel-Azim
    Alshawkani, Hamed A.
    Mattoo, Khurshid A.
    Mathur, Ankita
    Fiorillo, Luca
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (03) : 860 - 868
  • [35] Effects of Taper Angle and Sealant Agents on Bacterial Leakage Along the Implant-Abutment Interface: An In Vitro Study Under Loaded Conditions
    Ozdiler, Arda
    Bakir-Topcuoglu, Nursen
    Kulekci, Guven
    Isik-Ozkol, Gulbahar
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) : 1071 - 1077
  • [36] Evaluation of Implant-Abutment Microgap and Bacterial Leakage in Five External-Hex Implant Systems: An In Vitro Study
    Lopes de Chaves e Mello Dias, Eduardo Claudio
    Cargnin Bisognin, Edecir Decio
    Harari, Nassim David
    Machado, Silvio Jorge
    da Silva, Cristiano Pereira
    de Almeida Soares, Gloria Dulce
    Vidigal, Guaracilei Maciel, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 346 - 351
  • [37] Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants
    Schwitalla, Andreas Dominik
    Zimmermann, Tycho
    Spintig, Tobias
    Abou-Emara, Mohamed
    Lackmann, Justus
    Mueller, Wolf-Dieter
    Houshmand, Alireza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 77 : 85 - 89
  • [38] Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study
    Cascos, Rocio
    Celemin-Vinuela, Alicia
    Mory-Rubinos, Nataly
    Gomez-Polo, Cristina
    Ortega, Rocio
    Agustin-Panadero, Ruben
    Gomez-Polo, Miguel
    MATERIALS, 2023, 16 (19)
  • [39] Human osteoblasts response to different dental implant abutment materials: An in-vitro study
    Osman, Muataz A.
    Alamoush, Rasha A.
    Kushnerev, Evgeny
    Seymour, Kevin G.
    Shawcross, Susan
    Yates, Julian M.
    DENTAL MATERIALS, 2022, 38 (09) : 1547 - 1557
  • [40] Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: A comparative in vitro study
    Stimmelmayr, Michael
    Edelhoff, Daniel
    Gueth, Jan-Frederik
    Erdelt, Kurt
    Happe, Arndt
    Beuer, Florian
    DENTAL MATERIALS, 2012, 28 (12) : 1215 - 1220