Bacterial Colonization of the Implant-Abutment Interface (IAI) of Dental Implants with a Sloped Marginal Design: An in-vitro Study

被引:30
|
作者
Koutouzis, Theofilos [1 ]
Gadalla, Hana [2 ]
Lundgren, Tord [3 ]
机构
[1] Nova SE Univ, Coll Dent Med, Dept Periodontol, 3200 South Univ Dr, Ft Lauderdale, FL 33327 USA
[2] Univ Detroit Mercy, Sch Dent, Dept Periodontol, Detroit, MI 48221 USA
[3] King Faisal Specialist Hosp & Res Ctr, Dept Dent, Jeddah, Saudi Arabia
关键词
bacterial counts; bacterial leakage; dental implants; in vitro; titanium; FIXED PARTIAL DENTURES; CRESTAL BONE CHANGES; SUBMERGED IMPLANTS; INTERNAL SURFACES; ALVEOLAR RIDGE; LEVEL CHANGES; MICROGAP; INFLAMMATION; LEAKAGE; PART;
D O I
10.1111/cid.12287
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim of this study is to utilize an in vitro dynamic loading model to assess the potential risk of bacterial invasion into the Implant Abutment Interface (IAI) microgap of dental implants with sloped marginal design. Materials and MethodsForty implants were divided into two groups (n=20 per group) based on implant marginal design. Group 1 was comprised of implants with Morse-taper connection and conventional marginal design that connected to titanium abutments. Group 2 was comprised of implants with Morse-taper connection and sloped marginal design that connected to titanium abutments. The specimens were immersed in a bacterial solution of E.coli and loaded with 500,000 cycles of 160N using a chewing simulator. Following disconnection of fixtures and abutments, microbial samples were taken from the threaded portion of the abutment, plated and cultured under appropriate conditions. ResultsTen out of twenty implants of Group 1 and eight out of twenty implants of Group 2 had IAI microgaps colonized by E.Coli. There was not a statistically significant difference in the mean number of E.ColiCFU detected between implants of Group 1 (mean 19.2, SD 23.6) and Group 2 (mean 12.5, SD18.9) (p>.05). ConclusionsThe present study demonstrated that implants with a sloped marginal design exhibited similar risk for bacterial invasion into the IAI microgap under in vitro dynamic loading conditions compared to implants with conventional marginal design.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 50 条
  • [41] Effect of initial placement level and wall thickness on maintenance of the marginal bone level in implants with a conical implant-abutment interface: a 5-year retrospective study
    Yoo, Jaehyun
    Moon, Ik-Sang
    Yun, Jeong-Ho
    Chung, Chooryung
    Huh, Jong-Ki
    Lee, Dong-Won
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2019, 49 (03): : 185 - 192
  • [42] Evaluation of Antimicrobial Efficacy and Permeability of Various Sealing Materials at the Implant-Abutment Interface-A Pilot In Vitro Study
    Smojver, Igor
    Vuletic, Marko
    Gerbl, Drazena
    Budimir, Ana
    Susic, Mato
    Gabric, Dragana
    MATERIALS, 2021, 14 (02) : 1 - 11
  • [43] Marginal Bone Loss Around Short Dental Implants Restored at Implant Level and with Transmucosal Abutment: A Retrospective Study
    Hernandez-Marcos, Gabriel
    Hernandez-Herrera, Mariela
    Anitua, Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1362 - 1367
  • [44] Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study
    He, Yiting
    Fok, Alex
    Aparicio, Conrado
    Teng, Wei
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (04) : 741 - 752
  • [45] Crestal and Subcrestal Placement of Morse Cone Implant-Abutment Connection Implants: An In Vitro Finite Element Analysis (FEA) Study
    Comuzzi, Luca
    Ceddia, Mario
    Di Pietro, Natalia
    Inchingolo, Francesco
    Inchingolo, Angelo Michele
    Romasco, Tea
    Tumedei, Margherita
    Specchiulli, Alessandro
    Piattelli, Adriano
    Trentadue, Bartolomeo
    BIOMEDICINES, 2023, 11 (11)
  • [46] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333
  • [47] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: An in-vitro study
    Rismanchian M.
    Afshari M.
    Afshari, Mojtaba (Afshari.m1989@gmail.com), 1600, Inderscience Publishers (34): : 319 - 333
  • [48] In Vitro Analysis of Post-fatigue Reverse-Torque Values at the Dental Abutment/Implant Interface for a Unitarian Abutment Design
    Cashman, Paul M.
    Schneider, Robert L.
    Schneider, Galen B.
    Stanford, Clark M.
    Clancy, James M.
    Qian, Fang
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (07): : 503 - 509
  • [49] Stereomicroscopic Evaluation of Marginal Fit of Premachined and Castable Abutments at Implant Abutment Connection Interface - An In Vitro Study
    Kumar, Prince
    Singh, Swarndeep
    Mishra, Sunil Kumar
    JOURNAL OF THE SCIENTIFIC SOCIETY, 2023, 50 (02) : 254 - 258
  • [50] Evaluation of resistance against bacterial microleakage of a new conical implant-abutment connection versus conventional connections: an in vitro study
    Gherlone, Enrico Felice
    Cappare, Paolo
    Pasciuta, Renee
    Grusovin, Maria Gabriella
    Mancini, Nicasio
    Burioni, Roberto