PREVENTION OF BACTERIAL LEAKAGE AT IMPLANT-ABUTMENT CONNECTION LEVEL: AN IN VITRO STUDY OF THE EFFICACY OF THREE DIFFERENT IMPLANT SYSTEMS

被引:0
|
作者
Carinci, F. [1 ]
Lauritano, D. [2 ]
Cura, F. [3 ]
Lopez, M. A.
Bassi, M. Andreasi
Confalone, L.
Pezzetti, F. [3 ]
机构
[1] Univ Ferrara, Dept Morphol Surg & Expt Med, Ferrara, Italy
[2] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[3] Univ Bologna, Dept Expt Diagnost & Specialty Med, Bologna, Italy
关键词
dental implants; microleakage; dental abutments; microbiology; CHRONIC PERIODONTITIS; INTERFACE; MICROLEAKAGE; DIOXIDE; SEAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peri-implantitis is the main cause of implant failures. Peri-implantitis is provoked by the presence of bacterial infiltration around Implant-Abutment Connection (IAC). Reduction of bacterial leakage may be achieved by improving the accuracy and precision of the two pieces of IAC. The aim of the present in vitro study was to evaluate bacterial microleakage from the inside to the outside of the IAC, testing the efficacy of three new designs of internal conical connection (FN - nano-fix - NQ - uNiQo - and Elisir implant systems by FMD, Rome, Italy). To identify the efficacy of three new IAC, the passage of genetically modified Escherichia coli across IAC was evaluated. A total of 17 implants were used (5 FN, 6 NQ and 6 Elisir). All implants were immerged in a bacterial culture for 48 h and bacteria amount was then measured inside and outside IAC with Real-time PCR. Bacterial quantification was performed by Real-Time Polymerase Chain Reaction using the absolute quantification with the standard curve method. In all the tested implants, bacteria were found in the inner side, with a median percentage of 1.9% FN, 1.4% NQ and 2.6% Elisir. The analysis revealed that in both cases (internally and externally), bacteria grew in the first 48 hours but subsequently started to die, probably due to nutrient consumption. Of the three, the most efficacious connection was NQ. Within the limitations of this study, it was concluded that the best implant connection reducing bacterial leakage al IAC level was NQ (NQ implant system by FMD, Rome, Italy).
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [1] Bacterial Leakage and Microgap along Implant-Abutment Connection in Three Different Implant Systems
    Bajoghli, Farshad
    Amjadi, Mehrak
    Akouchekian, Mohadese
    Narimani, Tahmineh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 1284 - 1290
  • [2] In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    Steinebrunner, L
    Wolfart, S
    Bössmann, K
    Kern, M
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (06) : 875 - 881
  • [3] Bacterial Leakage in Implants With Different Implant-Abutment Connections: An In Vitro Study
    Assenza, Bartolomeo
    Tripodi, Domenico
    Scarano, Antonio
    Perrotti, Vittoria
    Piattelli, Adriano
    Iezzi, Giovanna
    D'Ercole, Simonetta
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (04) : 491 - 497
  • [4] THE ROLE OF IMPLANT-ABUTMENT CONNECTION IN PREVENTING BACTERIAL LEAKAGE: A REVIEW
    Candotto, V
    Gabrione, F.
    Oberti, L.
    Lento, D.
    Severino, M.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (03): : 129 - 134
  • [5] Association Between Implant-Abutment Microgap and Implant Circularity to Bacterial Leakage: An In Vitro Study Using Tapered Connection Implants
    Lopes de Chaves e Mello Dias, Eduardo Claudio
    Sperandio, Marcelo
    Napimoga, Marcelo Henrique
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (03) : 505 - 511
  • [6] Evaluation of Implant-Abutment Microgap and Bacterial Leakage in Five External-Hex Implant Systems: An In Vitro Study
    Lopes de Chaves e Mello Dias, Eduardo Claudio
    Cargnin Bisognin, Edecir Decio
    Harari, Nassim David
    Machado, Silvio Jorge
    da Silva, Cristiano Pereira
    de Almeida Soares, Gloria Dulce
    Vidigal, Guaracilei Maciel, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 346 - 351
  • [7] In Vitro Evaluation of Leakage at Implant-Abutment Connection of Three Implant Systems Having the Same Prosthetic Interface Using Rhodamine B
    Berberi, Antoine
    Tehini, Georges
    Rifai, Khaldoun
    Eddine, Farah Bou Nasser
    El Zein, Nabil
    Badran, Bassam
    Akl, Haidar
    INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014
  • [8] Bacterial Leakage at Implant-Abutment Interface With Different Intermediate Materials
    Mohammadi, Farnoush
    Hajmousaei, Maryam
    Vaziri, Nastaran
    Arshad, Mahnaz
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (06) : 451 - 455
  • [9] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [10] Analysis of Implant Strength After Implantoplasty in Three Implant-Abutment Connection Designs: An In Vitro Study
    Alexandre Gehrke, Sergio
    Aramburu Junior, Jaime Sarda
    Dedavid, Berenice Anina
    Shibli, Jamil Awad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E65 - E70