Bacterial Leakage at Implant-Abutment Interface With Different Intermediate Materials

被引:5
|
作者
Mohammadi, Farnoush [1 ,2 ]
Hajmousaei, Maryam [3 ]
Vaziri, Nastaran [4 ]
Arshad, Mahnaz [1 ,5 ]
机构
[1] Univ Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Tehran, Iran
[3] Univ Tehran Med Sci, Tehran, Iran
[4] Univ Tehran Med Sci, Sch Dent, Int Campus, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Dent, Dept Prosthodont, Int Campus, Tehran, Iran
关键词
dental implant-abutment interface; bacterial leakage; implant; IN-VITRO EVALUATION; HISTOMETRIC EVALUATION; SUBMERGED IMPLANTS; TITANIUM IMPLANTS; PERI-IMPLANTITIS; CHLORHEXIDINE; MICROLEAKAGE; TETRACYCLINE; CONNECTIONS; BONE;
D O I
10.1563/aaid-joi-D-18-00313
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A gap exists at the implant-abutment interface in two-piece implants and can serve as a reservoir of bacteria and compromise the health of peri-implant tissue. This study aimed to compare the effect of different intermediate materials on bacterial leakage at the implant-abutment interface. A total of 75 implants were divided into 5 groups (n = 15) based on the material applied at the implant-abutment connection: (1) Atridox, (2) chlorhexidine, (3) Gapseal silicone, (4) saliva, and (5) no material. All the implants were inoculated with 0.1 mu L of Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans) suspension, and then the respective material was applied. The abutments were connected to the implants, and appropriate torque was applied as recommended by the manufacturer (Implantium, Dentium, Korea, Seoul). Bacterial leakage was determined by evaluating the turbidity of the broth. Bacterial contamination was found in all samples at different times; in groups 1, 2 and 3, contamination was noted after 7, 5, and 6 days, respectively, on average. Contamination occurred averagely after 4 days in groups 4 and 5. The present study showed that Atridox applied at the implant-abutment interface significantly delayed bacterial leakage.
引用
收藏
页码:451 / 455
页数:5
相关论文
共 50 条
  • [1] In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    Steinebrunner, L
    Wolfart, S
    Bössmann, K
    Kern, M
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (06) : 875 - 881
  • [2] Bacterial leakage along the implant-abutment interface of premachined or cast components
    do Nascimento, C.
    Barbosa, R. E. S.
    Issa, J. P. M.
    Watanabe, E.
    Ito, I. Y.
    Junior, R. F. Albuquerque
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (02) : 177 - 180
  • [3] Bacterial Leakage in Implants With Different Implant-Abutment Connections: An In Vitro Study
    Assenza, Bartolomeo
    Tripodi, Domenico
    Scarano, Antonio
    Perrotti, Vittoria
    Piattelli, Adriano
    Iezzi, Giovanna
    D'Ercole, Simonetta
    JOURNAL OF PERIODONTOLOGY, 2012, 83 (04) : 491 - 497
  • [4] Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface
    do Nascimento, Cassio
    Pedrazzi, Vinicius
    Miani, Paola Kirsten
    Moreira, Larissa Daher
    de Albuquerque Junior, Rubens Ferreira
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (12) : 1394 - 1397
  • [5] Bacterial Leakage and Microgap along Implant-Abutment Connection in Three Different Implant Systems
    Bajoghli, Farshad
    Amjadi, Mehrak
    Akouchekian, Mohadese
    Narimani, Tahmineh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 1284 - 1290
  • [6] Microbial leakage and marginal fit of the implant-abutment interface
    Jansen, VK
    Conrads, G
    Richter, EJ
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (04) : 527 - 540
  • [7] Micro-leakage at the implant-abutment interface with different tightening torques in vitro
    da Silva-Neto, Joao Paulo
    Prudente, Marcel Santana
    Prado Naves Carneiro, Thiago de Almeida
    de Arruda Nobilo, Mauro Antonio
    Amante Penatti, Mario Paulo
    das Neves, Flavio Domingues
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (05) : 581 - 587
  • [8] Bacterial leakage along the implant-abutment interface: culture and DNA Checkerboard hybridization analyses
    do Nascimento, Cassio
    Miani, Paola Kirsten
    Pedrazzi, Vinicius
    Muller, Katia
    de Albuquerque Junior, Rubens Ferreira
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1168 - 1172
  • [9] THE ROLE OF IMPLANT-ABUTMENT CONNECTION IN PREVENTING BACTERIAL LEAKAGE: A REVIEW
    Candotto, V
    Gabrione, F.
    Oberti, L.
    Lento, D.
    Severino, M.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (03): : 129 - 134
  • [10] Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study
    D'Ercole, Simonetta
    Dotta, Tatiane Cristina
    Farani, Marzieh Ramezani
    Etemadi, Niloofar
    Iezzi, Giovanna
    Comuzzi, Luca
    Piattelli, Adriano
    Petrini, Morena
    BIOENGINEERING-BASEL, 2022, 9 (07):