Bacterial Leakage at Implant-Abutment Interface With Different Intermediate Materials
被引:5
|
作者:
Mohammadi, Farnoush
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
Univ Tehran Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Tehran, IranUniv Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
Mohammadi, Farnoush
[1
,2
]
Hajmousaei, Maryam
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Tehran, IranUniv Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
Hajmousaei, Maryam
[3
]
Vaziri, Nastaran
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran Med Sci, Sch Dent, Int Campus, Tehran, IranUniv Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
Vaziri, Nastaran
[4
]
论文数: 引用数:
h-index:
机构:
Arshad, Mahnaz
[1
,5
]
机构:
[1] Univ Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Dent, Dept Oral & Maxillofacial Surg, Tehran, Iran
[3] Univ Tehran Med Sci, Tehran, Iran
[4] Univ Tehran Med Sci, Sch Dent, Int Campus, Tehran, Iran
[5] Univ Tehran Med Sci, Sch Dent, Dept Prosthodont, Int Campus, Tehran, Iran
A gap exists at the implant-abutment interface in two-piece implants and can serve as a reservoir of bacteria and compromise the health of peri-implant tissue. This study aimed to compare the effect of different intermediate materials on bacterial leakage at the implant-abutment interface. A total of 75 implants were divided into 5 groups (n = 15) based on the material applied at the implant-abutment connection: (1) Atridox, (2) chlorhexidine, (3) Gapseal silicone, (4) saliva, and (5) no material. All the implants were inoculated with 0.1 mu L of Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans) suspension, and then the respective material was applied. The abutments were connected to the implants, and appropriate torque was applied as recommended by the manufacturer (Implantium, Dentium, Korea, Seoul). Bacterial leakage was determined by evaluating the turbidity of the broth. Bacterial contamination was found in all samples at different times; in groups 1, 2 and 3, contamination was noted after 7, 5, and 6 days, respectively, on average. Contamination occurred averagely after 4 days in groups 4 and 5. The present study showed that Atridox applied at the implant-abutment interface significantly delayed bacterial leakage.
机构:
Univ Witwatersrand, Fac Hlth Sci, Sch Oral Hlth Sci, Clin Unit,Dept Oral Med & Periodontol, Johannesburg, South AfricaUniv Witwatersrand, Fac Hlth Sci, Sch Oral Hlth Sci, Dept Oral Med & Periodontol, 7 York Rd, ZA-2193 Johannesburg, South Africa
Mohangi, Govindrau
Malo, Paulo
论文数: 0引用数: 0
h-index: 0
机构:
Malo Clin Hlth & Wellness, Av Combatentes 43A, P-1600042 Lisbon, PortugalUniv Witwatersrand, Fac Hlth Sci, Sch Oral Hlth Sci, Dept Oral Med & Periodontol, 7 York Rd, ZA-2193 Johannesburg, South Africa
Malo, Paulo
Nobre, Miguel
论文数: 0引用数: 0
h-index: 0
机构:
Malo Clin, Dept Res & Dev, Av Combatentes 43A, P-1600042 Lisbon, Portugal
Malo Clin, Oral Hyg Dept, Av Combatentes 43A, P-1600042 Lisbon, PortugalUniv Witwatersrand, Fac Hlth Sci, Sch Oral Hlth Sci, Dept Oral Med & Periodontol, 7 York Rd, ZA-2193 Johannesburg, South Africa