PREVENTION OF BACTERIAL LEAKAGE AT IMPLANT-ABUTMENT CONNECTION LEVEL: AN IN VITRO STUDY OF THE EFFICACY OF THREE DIFFERENT IMPLANT SYSTEMS

被引:0
|
作者
Carinci, F. [1 ]
Lauritano, D. [2 ]
Cura, F. [3 ]
Lopez, M. A.
Bassi, M. Andreasi
Confalone, L.
Pezzetti, F. [3 ]
机构
[1] Univ Ferrara, Dept Morphol Surg & Expt Med, Ferrara, Italy
[2] Univ Milano Bicocca, Dept Med & Surg, Milan, Italy
[3] Univ Bologna, Dept Expt Diagnost & Specialty Med, Bologna, Italy
关键词
dental implants; microleakage; dental abutments; microbiology; CHRONIC PERIODONTITIS; INTERFACE; MICROLEAKAGE; DIOXIDE; SEAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peri-implantitis is the main cause of implant failures. Peri-implantitis is provoked by the presence of bacterial infiltration around Implant-Abutment Connection (IAC). Reduction of bacterial leakage may be achieved by improving the accuracy and precision of the two pieces of IAC. The aim of the present in vitro study was to evaluate bacterial microleakage from the inside to the outside of the IAC, testing the efficacy of three new designs of internal conical connection (FN - nano-fix - NQ - uNiQo - and Elisir implant systems by FMD, Rome, Italy). To identify the efficacy of three new IAC, the passage of genetically modified Escherichia coli across IAC was evaluated. A total of 17 implants were used (5 FN, 6 NQ and 6 Elisir). All implants were immerged in a bacterial culture for 48 h and bacteria amount was then measured inside and outside IAC with Real-time PCR. Bacterial quantification was performed by Real-Time Polymerase Chain Reaction using the absolute quantification with the standard curve method. In all the tested implants, bacteria were found in the inner side, with a median percentage of 1.9% FN, 1.4% NQ and 2.6% Elisir. The analysis revealed that in both cases (internally and externally), bacteria grew in the first 48 hours but subsequently started to die, probably due to nutrient consumption. Of the three, the most efficacious connection was NQ. Within the limitations of this study, it was concluded that the best implant connection reducing bacterial leakage al IAC level was NQ (NQ implant system by FMD, Rome, Italy).
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [41] In vitro assessment of connection strength and stability of internal implant-abutment connections
    Kofron, Michelle D.
    Carstens, Matthew
    Fu, Cong
    Wen, Hai Bo
    CLINICAL BIOMECHANICS, 2019, 65 : 92 - 99
  • [42] Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs
    Bordin, Dimorvan
    Witek, Lukasz
    Fardin, Vinicius P.
    Bonfante, Estevam A.
    Coelho, Paulo G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 659 - 664
  • [43] Fracture resistance after implantoplasty in three implant-abutment connection designs
    Camps-Font, Octavi
    Gonzalez-Barnadas, Albert
    Mir-Mari, Javier
    Figueiredo, Rui
    Gay-Escoda, Cosme
    Valmaseda-Castellon, Eduard
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2020, 25 (05): : E691 - E699
  • [44] Microbiological Evaluation of Bacterial and Mycotic Seal in Implant Systems With Different Implant-Abutment Interfaces and Closing Torque Values
    Baggi, Luigi
    Di Girolamo, Michele
    Mirisola, Concetta
    Calcaterra, Roberta
    IMPLANT DENTISTRY, 2013, 22 (04) : 344 - 350
  • [45] Evaluation of different debridement strategies for implant-abutment connections: An in vitro
    Lang, Lilly K.
    Karl, Matthias
    Klaer, Virgilia
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 738.e1 - 738.e8
  • [46] Assessment of Microgap and Bacterial Leakage of Two Types of Internal Implant-Abutment Union
    Basha, Shaik Riyaz
    Channamsetty, Praveena
    Janapati, Divya
    Badugu, Satyavathi
    Kodipalli, Sravalli
    Ireddy, Kavya Sri
    Mitra, Nirban
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S792 - S793
  • [47] Abutment Coating With Diamond-Like Carbon Films to Reduce Implant-Abutment Bacterial Leakage
    Cardoso, Mayra
    Sangalli, Jorgiana
    Koga-Ito, Cristiane Yumi
    Ferreira, Leandro Lameirao
    da Silva Sobrinho, Argemiro Soares
    Nogueira, Lafayette, Jr.
    JOURNAL OF PERIODONTOLOGY, 2016, 87 (02) : 168 - 174
  • [48] Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface
    do Nascimento, Cassio
    Pedrazzi, Vinicius
    Miani, Paola Kirsten
    Moreira, Larissa Daher
    de Albuquerque Junior, Rubens Ferreira
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (12) : 1394 - 1397
  • [49] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113
  • [50] An In Vitro Investigation Concerning the Bacterial Leakage at Implants With Internal Hexagon and Morse Taper Implant-Abutment Connections
    Tripodi, Domenico
    Vantaggiato, Giovanni
    Scarano, Antonio
    Perrotti, Vittoria
    Piattelli, Adriano
    Iezzi, Giovanna
    D'Ercole, Simonetta
    IMPLANT DENTISTRY, 2012, 21 (04) : 335 - 339