Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours

被引:16
|
作者
Ertl, A
Zehetmayer, M
Schoggl, A
Kindl, P
Hartl, R
机构
[1] UNIV VIENNA, DEPT OPHTHALMOL, A-1090 VIENNA, AUSTRIA
[2] GRAZ TECH UNIV, INST TECH PHYS, A-8010 GRAZ, AUSTRIA
[3] TECH UNIV VIENNA, AUSTRIAN ATOM INST, A-1060 VIENNA, AUSTRIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 11期
关键词
D O I
10.1088/0031-9155/42/11/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Between March 1993 and January 1997, stereotactic radiation techniques were used to irradiate 66 intraocular tumour patients with the Gamma Knife (Leksell Gamma Knife(R), model B unit) at the University of Vienna, Austria. This study investigates the dosimetry for stereotactic irradiation of ocular structures. For the dosimetry program KULA 4.4, Gamma Knife stereotactic irradiation of the eye represents an extreme frontal skull position. In addition, irradiation of the eye may be performed in the usual supine position in exceptional cases only. With the patient in the prone position, the dose planning program has to calculate with a significantly large number of single-beam extrapolations. In our first experiment we measured the isocentre dose for eight different gamma-angle positions, both in prone and supine positions, using TLD measurements in an Alderson head phantom. We found a maximum deviation of +/-1.6% using these individually calibrated TLDs. In the second experiment we examined the dose cross profiles for the two most frequently used treatment positions (supine position, gamma = 65 degrees, and prone position, gamma = 140 degrees). For this purpose we implanted a specially designed TLD array into the orbit of a human cadaver head. We found excellent agreement of the dose values measured for the isocentre as well as the posterior part of the eye with orbit with deviations of less than -2.7%. However, for the anterior part of the eye, deviations between computer-generated calculations and the TLD measurements were found to range up to -30%. These differences were noticed both for supine and prone positions. For the Gamma Knife stereotactic irradiation of ocular tumours or pathologies, precautions should be taken to avoid significant underdosage in the anterior part of the radiation field.
引用
收藏
页码:2137 / 2145
页数:9
相关论文
共 50 条
  • [41] TLD array for precise dose measurements in stereotactic radiation techniques
    Ertl, A
    Hartl, RFE
    Zehetmayer, M
    Kitz, K
    Griffitt, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12): : 2679 - 2686
  • [42] A model in the optimisation of converging multiple field techniques in stereotactic radiation
    Hodapp, N.
    Wiehle, R.
    Roehner, F.
    Ioan, O.
    Koth, H. -J.
    Passmann, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 18 - 19
  • [43] Stereotactic body radiation therapy - Rationale, techniques, applications, and optimization
    Song, Danny Y.
    Kavanagh, Brian D.
    Benedict, Stanley H.
    Schefter, Tracey
    ONCOLOGY-NEW YORK, 2004, 18 (11): : 1419 - 1430
  • [44] In Vivo Dosimetry of Stereotactic Radiation Therapy Using Integral Quality Monitor (IQM) System
    Qian, J.
    Lin, L.
    Gonzales, R.
    Keck, J.
    Armour, E. P.
    Wong, J. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E614 - E614
  • [45] The impact of heterogeneity correction on tumor dosimetry for lung cancer stereotactic body radiation therapy
    Ding, M
    Newman, F
    Stuhr, K
    MEDICAL PHYSICS, 2005, 32 (06) : 2046 - 2046
  • [46] MONTE-CARLO DOSIMETRY FOR STEREOTACTIC SYNCHROTRON RADIATION THERAPY (SSRT) FOR BRAIN TUMORS
    Alonso, Y. Prezado
    Adam, J. F.
    Bravin, A.
    Edouard, M.
    Ellaume, H.
    Esteve, F.
    Nemoz, C.
    Renier, M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S115 - S115
  • [47] Early results of a remote dosimetry audit program for lung stereotactic body radiation therapy
    Yalvac, Burak
    Reulens, Nathalie
    Reniers, Brigitte
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [48] Validation and comparison of dosimetry for small lung targets in Stereotactic Body Radiation Therapy (SBRT)
    Boike, T.
    Park, K.
    Lee, P.
    Edwards, M.
    Shakouri, S.
    Shaddock, S.
    DeRose, P.
    Abdulrahman, R.
    Timmerman, R.
    Solberg, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S617 - S618
  • [49] IONIZING RADIATION DOSIMETRY IN HUMAN CELLS CYTOGENETIC STUDIES
    Mroz, Tomasz
    Kornas, Andrzej
    POSTEPY BIOLOGII KOMORKI, 2015, 42 (03) : 491 - 503
  • [50] NEUTRON DOSIMETRY IN RADIATION-DAMAGE STUDIES OF STEEL
    ROBINSON, GC
    NUCLEAR SAFETY, 1967, 8 (04): : 370 - &