TLD array for precise dose measurements in stereotactic radiation techniques

被引:15
|
作者
Ertl, A
Hartl, RFE
Zehetmayer, M
Kitz, K
Griffitt, W
机构
[1] VIENNA TECH UNIV,INST NUCL RES,VIENNA,AUSTRIA
[2] UNIV VIENNA,DEPT OPHTHALMOL,ONCOL SERV,VIENNA,AUSTRIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1996年 / 41卷 / 12期
关键词
D O I
10.1088/0031-9155/41/12/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy.
引用
收藏
页码:2679 / 2686
页数:8
相关论文
共 50 条
  • [1] PRECISE MEASUREMENT OF STEREOTACTIC LINAC RADIATION POSITION PARAMETERS USING A PHOTODIODE ARRAY
    Spencer, D.
    Nygren, I.
    Balderson, M.
    Brown, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S114 - S114
  • [2] AMBIENT DOSE AND DOSE RATE MEASUREMENTS IN THE VICINITY OF ELEKTA PRECISE ACCELERATORS FOR RADIATION THERAPY
    Zutz, H.
    Hupe, O.
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (04) : 431 - 437
  • [3] FACTORS AFFECTING THE PRECISION OF TLD DOSE MEASUREMENTS USING AN AUTOMATIC TLD READER
    WOOD, JJ
    MAYLES, WPM
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02): : 309 - 313
  • [4] Comparative study of precise measurements of natural radionuclides and radiation dose using in-situ and laboratory γ-ray spectroscopy techniques
    N. M. Hassan
    Y. J. Kim
    J. Jang
    B. U. Chang
    J. S. Chae
    Scientific Reports, 8
  • [5] Comparative study of precise measurements of natural radionuclides and radiation dose using in-situ and laboratory γ-ray spectroscopy techniques
    Hassan, N. M.
    Kim, Y. J.
    Jang, J.
    Chang, B. U.
    Chae, J. S.
    SCIENTIFIC REPORTS, 2018, 8
  • [6] Practical Treatment Techniques for Fetal Dose Reduction in Intracranial Stereotactic Radiation Therapy
    Giles, W.
    Yin, F.
    Torok, J.
    Rodrigues, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E373 - E373
  • [7] Absolute dose measurements for lung gated delivery stereotactic body radiation therapy
    Savanovic, M.
    Jaros, D.
    Chauchat, P.
    Foulquier, J. N.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [8] Tumour dose estimation using automated TLD techniques
    Ferguson, HM
    Lambert, GD
    Gustard, D
    Harrison, RM
    ACTA ONCOLOGICA, 1998, 37 (05) : 479 - 484
  • [9] TLD extrapolation measurements for entrance and exit dose in radiotherapy
    Kron, T
    Ostwald, PM
    Hamilton, CS
    Denham, JW
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 323 - 326