TLD array for precise dose measurements in stereotactic radiation techniques

被引:15
|
作者
Ertl, A
Hartl, RFE
Zehetmayer, M
Kitz, K
Griffitt, W
机构
[1] VIENNA TECH UNIV,INST NUCL RES,VIENNA,AUSTRIA
[2] UNIV VIENNA,DEPT OPHTHALMOL,ONCOL SERV,VIENNA,AUSTRIA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1996年 / 41卷 / 12期
关键词
D O I
10.1088/0031-9155/41/12/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy.
引用
收藏
页码:2679 / 2686
页数:8
相关论文
共 50 条
  • [21] Characteristics of TLD and PSLD Films for Photon and Electron Dose Measurements
    Kurokawa, C.
    Urushiyama, A.
    Nishio, T.
    Sugimoto, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Dose and energy measurements in radio therapy by a combination of TLD100 and TLD100H
    Hauri, Pascal
    Schneider, Uwe
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 837 - 838
  • [23] ENVIRONMENTAL RADIATION MEASUREMENTS USING TLD IN AND AROUND AERE, DHAKA
    MOLLAH, AS
    HUSAIN, SR
    RAHMAN, MM
    RADIATION PROTECTION DOSIMETRY, 1986, 14 (03) : 261 - 263
  • [24] Dose Tolerance for Stereotactic Body Radiation Therapy
    Grimm, Jimm
    SEMINARS IN RADIATION ONCOLOGY, 2016, 26 (02) : 87 - 88
  • [25] TLD MEASUREMENTS OF DOSE DISTRIBUTION AROUND A BETA-RAY APPLICATOR
    RUDEN, BI
    BENGTSSON, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (02): : 186 - 195
  • [26] SUPERFICIAL TLD DOSE MEASUREMENTS FOR HEAD AND NECK CANCERS TREATED BY TOMOTHERAPY
    Pasquie, I.
    Poupon, E.
    Caradec, P.
    Munos, C.
    Bardet, E.
    Lisbona, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S393 - S393
  • [27] Stereotactic radiation techniques in the treatment of acoustic schwannomas
    Abram, Steven
    Rosenblatt, Paul
    Holcomb, Stephen
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2007, 40 (03) : 571 - +
  • [28] X-RAY SURFACE DOSE MEASUREMENTS USING TLD EXTRAPOLATION
    KRON, T
    ELLIOT, A
    WONG, T
    SHOWELL, G
    CLUBB, B
    METCALFE, P
    MEDICAL PHYSICS, 1993, 20 (03) : 703 - 711
  • [29] Simultaneous Double Dose Measurements Using TLD-100H
    Stella, Giuseppe
    Sallah, Antouman
    Galvagno, Rosaria
    D'Anna, Alessia
    Gueli, Anna Maria
    CRYSTALS, 2024, 14 (07)
  • [30] MIXED FIELD RADIATION MEASUREMENTS USING LIF-7 TLD
    GOMAA, MA