3D silicon strip detectors

被引:1
|
作者
Parzefall, Ulrich [1 ]
Bates, Richard [2 ]
Boscardin, Maurizio [3 ]
Betta, Gian-Franco Dalla [4 ,5 ]
Eckert, Simon [1 ]
Eklund, Lars [2 ]
Fleta, Celeste [2 ]
Jakobs, Karl [1 ]
Kuehn, Susanne [1 ]
Lozano, Manuel [6 ]
Pahn, Gregor [1 ]
Parkes, Chris [2 ]
Pellegrini, Giulio [6 ]
Pennicard, David [2 ]
Piemonte, Claudio [3 ]
Ronchin, Sabina [3 ]
Szumlak, Tomasz [2 ]
Zoboli, Andrea [4 ,5 ]
Zorzi, Nicola [3 ]
机构
[1] Univ Freiburg, Inst Phys, D-79104 Freiburg, Germany
[2] Univ Glasgow, Dept Phys & Astron, Glasgow G12 8QQ, Lanark, Scotland
[3] Ctr Mat & Microsyst, FBK Irst, I-38050 Povo, Italy
[4] Univ Trent, I-38050 Povo, Italy
[5] Ist Nazl Fis Nucl, I-38050 Povo, Italy
[6] CSIC, IMB CNM, Inst Microelect Barcelona, Barcelona, Spain
关键词
Silicon detectors; 3D detectors; ATLAS SEMICONDUCTOR TRACKER; COLUMNAR ELECTRODES; DOPING TYPE; MODULE;
D O I
10.1016/j.nima.2009.01.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
While the Large Hadron Collider (LHC) at CERN has started operation in autumn 2008, plans for a luminosity upgrade to the Super-LHC (sLHC) have already been developed for several years. This projected luminosity increase by an order of magnitude gives rise to a challenging radiation environment for tracking detectors at the LHC experiments. Significant improvements in radiation hardness are required with respect to the LHC. Using a strawman layout for the new tracker of the ATLAS experiment as an example, silicon strip detectors (SSDs) with short strips of 2-3 cm length are foreseen to cover the region from 28 to 60 cm distance to the beam. These SSD will be exposed to radiation levels up to 10(15) N(eq)/cm(2), which makes radiation resistance a major concern for the upgraded ATLAS tracker. Several approaches to increasing the radiation hardness of silicon detectors exist. In this article, it is proposed to combine the radiation hard 3D-design originally conceived for pixel-style applications with the benefits of the established planar technology for strip detectors by using SSDs that have regularly spaced doped columns extending into the silicon bulk under the detector strips. The first 3D SSDs to become available for testing were made in the Single Type Column (STC) design, a technological simplification of the original 3D design. With such 3D SSDs, a small number of prototype sLHC detector modules with LHC-speed front-end electronics as used in the semiconductor tracking systems of present LHC experiments were built. Modules were tested before and after irradiation to fluences of 10(15) N(eq)/cm(2). The tests were performed with three systems: a highly focused IR-laser with 5 mu m spot size to make position-resolved scans of the charge collection efficiency, an Sr(90) beta-source set-up to measure the signal levels for a minimum ionizing particle (MIP), and a beam test with 180 GeV pions at CERN. This article gives a brief overview of the results obtained with 3D-STC-modules. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:234 / 237
页数:4
相关论文
共 50 条
  • [31] 3D silicon pixel detectors for the High-Luminosity LHC
    Lange, J.
    Areste, M. Carulla
    Cavallaro, E.
    Foerster, F.
    Grinstein, S.
    Paz, I. Lopez
    Manna, M.
    Pellegrini, G.
    Quirion, D.
    Terzo, S.
    Furelos, D. Vazquez
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [32] 3D simulations of new low capacitance silicon pixel detectors
    Long, Qiang
    Guo, Qinwen
    Long, Zhongliang
    Li, Zheng
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL FORUM ON MANAGEMENT, EDUCATION AND INFORMATION TECHNOLOGY APPLICATION (IFMEITA 2017), 2017, 130 : 566 - 569
  • [33] Slim edges in double-sided silicon 3D detectors
    Povoli, M.
    Bagolini, A.
    Boscardin, M.
    Dalla Betta, G. -F.
    Giacomini, G.
    Vianello, E.
    Zorzi, N.
    [J]. JOURNAL OF INSTRUMENTATION, 2012, 7
  • [34] 3D silicon pixel detectors for the ATLAS Forward Physics experiment
    Lange, J.
    Cavallaro, E.
    Grinstein, S.
    Lopez Paz, I.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [35] The geometrical dependence of radiation hardness in planar and 3D silicon detectors
    Davia, C.
    Watts, S. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 319 - 324
  • [36] New 3D Silicon detectors for dosimetry in Microbeam Radiation Therapy
    Lerch, M. L. F.
    Dipuglia, A.
    Cameron, M.
    Fournier, P.
    Davis, J.
    Petasecca, M.
    Cornelius, I.
    Perevertaylo, V.
    Rosenfeld, A. B.
    [J]. MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [37] Design, simulation, production and initial characterisation of 3D silicon detectors
    Pennicard, D.
    Pellegrini, G.
    Lozano, M.
    Fleta, C.
    Bates, R.
    Parkes, C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 67 - 70
  • [38] Evaluation of a Compton camera concept using the 3D CdZnTe drift strip detectors
    Owe, S. Howalt
    Kuvvetli, I.
    Budtz-Jorgensen, C.
    Zoglauer, A.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14
  • [39] CHARGE COLLECTION IN SILICON STRIP DETECTORS
    BELAU, E
    KLANNER, R
    LUTZ, G
    NEUGEBAUER, E
    SEEBRUNNER, HJ
    WYLIE, A
    BOHRINGER, T
    HUBBELING, L
    WEILHAMMER, P
    KEMMER, J
    KOTZ, U
    RIEBESELL, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 253 - 260
  • [40] Radiochromic 3D Detectors
    Oldham, Mark
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573