Radiochromic 3D Detectors

被引:18
|
作者
Oldham, Mark [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
OPTICAL COMPUTED-TOMOGRAPHY; POLYMER GEL DOSIMETRY; RADIATION-DOSE DISTRIBUTIONS; CT SCANNER; QUALITY-ASSURANCE; 3-DIMENSIONAL DOSIMETRY; SYSTEM; VERIFICATION; PRESAGE(TM); PERFORMANCE;
D O I
10.1088/1742-6596/573/1/012006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiochromic materials exhibit a colour change when exposed to ionising radiation. Radiochromic film has been used for clinical dosimetry for many years and increasingly so recently, as films of higher sensitivities have become available. The two principle advantages of radiochromic dosimetry include greater tissue equivalence (radiologically) and the lack of requirement for development of the colour change. In a radiochromic material, the colour change arises direct from ionising interactions affecting dye molecules, without requiring any latent chemical, optical or thermal development, with important implications for increased accuracy and convenience. It is only relatively recently however, that 3D radiochromic dosimetry has become possible. In this article we review recent developments and the current state-of-the-art of 3D radiochromic dosimetry, and the potential for a more comprehensive solution for the verification of complex radiation therapy treatments, and 3D dose measurement in general.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Methods and Applications of 3D Radiochromic Dosimetry
    Oldham, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3790 - 3790
  • [2] Radiochromic gels for UV radiation measurements in 3D
    Kozicki, Marek
    Kwiatos, Klaudia
    Dudek, Mariusz
    Stempien, Zbigniew
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2018, 351 : 197 - 207
  • [3] Investigation of a bleaching dye for 3D radiochromic dosimetry
    Hoye, E.
    Skyt, P. S.
    Muren, L. P.
    Petersen, J. B. B.
    Balling, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S142 - S142
  • [4] 3D silicon detectors
    Bates, R. L.
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 829 - 840
  • [5] Feasibility of radiochromic gels for 3D dosimetry of brachytherapy sources
    Solc, Jaroslav
    Sochor, Vladimir
    METROLOGIA, 2012, 49 (05) : S231 - S236
  • [6] An Investigation of the Dosimetric Characteristics of a Novel Radiochromic 3D Dosimeter
    Jackson, J.
    Juang, T.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Dosimetric characteristics of a reusable 3D radiochromic dosimetry material
    Park, Jong Min
    Park, So-Yeon
    Choi, Chang Heon
    Chun, Minsoo
    Han, Ji Hye
    Cho, Jin Dong
    Kim, Jung-in
    PLOS ONE, 2017, 12 (07):
  • [8] Full 3D simulations of BNL one-sided silicon 3D detectors and comparisons with other types of 3D detectors
    Gronlund, Tanja
    Li, Zheng
    Carini, Gabriella
    Li, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02): : 180 - 189
  • [9] On the Robustness of 3D Object Detectors
    Albreiki, Fatima
    Abu Ghazal, Sultan
    Lahoud, Jean
    Anwer, Rao
    Cholakkal, Hisham
    Khan, Fahad
    PROCEEDINGS OF THE 4TH ACM INTERNATIONAL CONFERENCE ON MULTIMEDIA IN ASIA, MMASIA 2022, 2022,
  • [10] Study of irradiated 3D detectors
    Roy, P
    Pellegrini, G
    Al-Ajili, A
    Bates, R
    Haddad, L
    Melone, J
    O'Shea, V
    Smith, KM
    Wright, V
    Rahman, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 132 - 137