The optimal angle of screw for using cement-screw technique to repair tibial defect in total knee arthroplasty: a finite element analysis

被引:6
|
作者
Zhao, Guanghui [1 ]
Yao, Shuxin [1 ]
Ma, Jianbing [1 ]
Wang, Jianpeng [1 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Joint Surg, 555 East Youyi Rd, Xian, Shanxi, Peoples R China
关键词
Cement-screw technique; Bone defect; Total knee arthroplasty; Finite element analysis; BONE DEFECTS; AUGMENTATION; REPLACEMENT; MANAGEMENT; INTERFACE; FRACTURE; STRESS; TKA;
D O I
10.1186/s13018-022-03251-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The cement-screw technique is a convenient method to repair tibial plateau defects in primary and revision total knee arthroplasty (TKA). However, the optimal angle of screw insertions is unknown. This study aimed to perform a finite element analysis (FEA) to determine the optimal screw angle for the repair of tibial plateau defects in TKA. Methods Seven FEA models were set and two common different defects (defect 1: area < 12%, depth < 12 mm; defect 2: area > 12%, depth > 12 mm) were simulated. One screw was used in defect 1, and one or two screws were used in defect 2. Screws were parallel to the proximal cortical bone (oblique screw) or perpendicular to the upper surface (vertical screw) of the tibia. Contact stresses on cancellous bone in different areas were determined. Maximum principal stress on the cancellous bone around each screw was also compared. Results The FEA models showed that stresses on the surface of cancellous bone in tibial defect (0.13-0.39 MPa) and stress focus spot (0.45 MPa) around the screw were lower when one vertical screw was used in defect 1. The stresses on the surface of cancellous bone in tibial defect (0.09-0.44 MPa), stresses in the medial tibial plateau (0.14-0.21 MPa), and stress focus spot around the screws were lowest (0.42 MPa and 1.37 MPa) when two vertical screws were used in defect 2, followed by of one vertical and one oblique (0.16-0.48 MPa; 0.15-0.21 MPa; 1.63 MPa and 1.11 MPa). No other statistically significant differences were found. Conclusions Either for one or two screws, those perpendicular to the upper surface achieve better stability than those parallel to the proximal cortical bone of the tibia. If two vertical screws cannot be performed, one vertical and one oblique is also acceptable.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Clinical results of unicompartmental arthroplasty for knee osteoarthritis using a tibial component with screw fixation
    Koshino, Tomihisa
    Sato, Koji
    Umemoto, Yusuke
    Akamatsu, Yasushi
    Kumagai, Ken
    Saito, Tomoyuki
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) : 1085 - 1091
  • [22] Clinical results of unicompartmental arthroplasty for knee osteoarthritis using a tibial component with screw fixation
    Tomihisa Koshino
    Koji Sato
    Yusuke Umemoto
    Yasushi Akamatsu
    Ken Kumagai
    Tomoyuki Saito
    International Orthopaedics, 2015, 39 : 1085 - 1091
  • [23] Stress Analysis in Conversion Total Hip Arthroplasty: A Finite Element Analysis on Stem Length and Distal Screw Hole
    Shimasaki, Koshiro
    Nishino, Tomofumi
    Yoshizawa, Tomohiro
    Watanabe, Ryunosuke
    Hirose, Fumi
    Yasunaga, Shota
    Mishima, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [24] Suction technique to improve cement penetration under the tibial component in total knee arthroplasty
    Stannage, K
    Shakespeare, D
    Bulsara, M
    KNEE, 2003, 10 (01): : 67 - 73
  • [25] Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty
    Ye-Ran Li
    Yu-Hang Gao
    Chen Yang
    Lu Ding
    Xuebo Zhang
    Hanzhe Chen
    Jianguo Liu
    Xin Qi
    BMC Musculoskeletal Disorders, 20
  • [26] Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty A FINITE ELEMENT ANALYSIS
    Suh, D-S.
    Kang, K-T.
    Son, J.
    Kwon, O-R.
    Baek, C.
    Koh, Y-G.
    BONE & JOINT RESEARCH, 2017, 6 (11): : 623 - 630
  • [27] Finite-element analysis of the proximal tibial sclerotic bone and different alignment in total knee arthroplasty
    Li, Ye-Ran
    Gao, Yu-Hang
    Yang, Chen
    Ding, Lu
    Zhang, Xuebo
    Chen, Hanzhe
    Liu, Jianguo
    Qi, Xin
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [28] Difference Between Screw Cement Filling and Adequate Osteotomy With Thick Liner for Primary Total Knee Arthroplasty in Patients With Rand IIb Tibial Defects
    Liu, Chengyan
    Li, Jintang
    Sun, Chao
    Wei, Zhilin
    Yang, Qifan
    Sun, Peng
    Li, Shuqiang
    JOURNAL OF ARTHROPLASTY, 2023, 38 (08): : 1510 - 1515
  • [29] Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
    Jun Young Lee
    Yeon Soo Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 842 - 849
  • [30] Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
    Lee, Jun Young
    Lee, Yeon Soo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (05) : 842 - 849