Optimal double screw configuration for subtalar arthrodesis: a finite element analysis (vol 19, pg 842, 2011)

被引:1
|
作者
Lee, Jun Young [2 ]
Lee, Yeon Soo [1 ]
机构
[1] Catholic Univ Daegu, Dept Biomed Engn, Coll Med Sci, Gyongsan 712702, Gyeongbuk, South Korea
[2] Chosun Univ, Dept Orthopaed Surg, Coll Med, Kwangju, South Korea
关键词
Ankle; Calcaneus; Finite element analysis; Screw fixation; Subtalar arthrodesis; Talus;
D O I
10.1007/s00167-011-1451-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The subtalar arthrodesis using screws has been performed to manage traumatic subtalar arthritis. Even though clinically there might not have been big difference between using single screw or double screws for subtalar arthrodesis, a double screw fixation is expected to bring a better initial stability in a mechanical view. This study aimed to assess the optimal configuration of double screw fixation for subtalar arthrodesis. From the CT-scanned images of an ankle of a Korean male (21 year old), polygon models of the talus and calcaneus were reconstructed. The polygon models were converted to tetrahedron finite elements. Young's modulus was assigned locally to each element based on the Hounsfield unit, and a Poisson's ratio of 0.4 was commonly. Four fixation configurations of double screw subtalar arthrodesis were modeled by combination of a same placement of a neck screw and one of four different placements of a dome screw, i.e., anterolateral (AL), anteromedial (AM), posterolateral (PL), and posteromedial (PM) placements. External and internal rotation torques of 4 N-m were applied when evaluating the stability of each fixation configuration. Among the four fixation configurations, the fixation configuration of a neck screw plus a PM dome screw had the least translation of 0.9 and 0.8 mm for external and internal rotational torques of 4 N-m, respectively. The fixation configuration of a neck screw plus a PM dome screw showed the least rotation of 5.0A degrees and 4.8A degrees for external and internal rotational torques of 4 N-m, respectively. The divergence angle or the contact length did not solely match well to the better stability. However, the integration of both the divergence angle of 2 screws and the contact length between screw and bones were proportionally related to the better rotational stability. A posteromedial dome screw combined with a neck screw can be the best surgical choice, which will bring out excellent union rate of the subtalar arthrodesis as well as the best mechanical stability.
引用
收藏
页码:867 / 867
页数:1
相关论文
共 50 条
  • [1] Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
    Jun Young Lee
    Yeon Soo Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 842 - 849
  • [2] Erratum to: Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
    Jun Young Lee
    Yeon Soo Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 867 - 867
  • [3] Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis
    Min Zhu
    Cheng-song Yuan
    Zhong-min Jin
    Yun-jiao Wang
    You-xing Shi
    Zhi-jin Yang
    Kanglai Tang
    Journal of Orthopaedic Surgery and Research, 13
  • [4] Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis
    Zhu, Min
    Yuan, Cheng-song
    Jin, Zhong-min
    Wang, Yun-jiao
    Shi, You-xing
    Yang, Zhi-jin
    Tang, Kanglai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [5] Finite element analysis of piezoelectric microgenerator - towards optimal configuration
    Dauksevicius, R.
    Kulvietis, G.
    Ostasevicius, V.
    Milasauskaite, I.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 1312 - 1315
  • [6] Initial stability of ankle arthrodesis with three-screw fixation.: A finite element analysis
    Alonso-Vázquez, A
    Lauge-Pedersen, H
    Lidgren, L
    Taylor, M
    CLINICAL BIOMECHANICS, 2004, 19 (07) : 751 - 759
  • [7] Melting in a Single Screw Extruder: Experiments and 3D Finite Element Simulations (vol 2, pg 182, 2011)
    Altinkaynak, A.
    Gupta, M.
    Spalding, M. A.
    Crabtree, S. L.
    INTERNATIONAL POLYMER PROCESSING, 2011, 26 (03) : 274 - 274
  • [8] Lapidus Arthrodesis with a Single Lag Screw and a Locking H-Plate (vol 50, pg 377, 2011)
    Menke, C. R. D.
    JOURNAL OF FOOT & ANKLE SURGERY, 2011, 50 (06): : 772 - 772
  • [9] Patient-specific finite element analysis of the human femur-A double-blinded biomechanical validation (vol 44, pg 1666, 2011)
    Trabelsi, Nir
    Yosibash, Zohar
    Wutte, Christof
    Augat, Peter
    Eberle, Sebastian
    JOURNAL OF BIOMECHANICS, 2012, 45 (04) : 724 - 725
  • [10] Fundamental considerations for the finite element analysis of shell structures. (vol 66, pg 19, 1998)
    Chapelle, D
    Bathe, KJ
    COMPUTERS & STRUCTURES, 1998, 66 (05) : 711 - 712