The optimal angle of screw for using cement-screw technique to repair tibial defect in total knee arthroplasty: a finite element analysis

被引:6
|
作者
Zhao, Guanghui [1 ]
Yao, Shuxin [1 ]
Ma, Jianbing [1 ]
Wang, Jianpeng [1 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Joint Surg, 555 East Youyi Rd, Xian, Shanxi, Peoples R China
关键词
Cement-screw technique; Bone defect; Total knee arthroplasty; Finite element analysis; BONE DEFECTS; AUGMENTATION; REPLACEMENT; MANAGEMENT; INTERFACE; FRACTURE; STRESS; TKA;
D O I
10.1186/s13018-022-03251-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The cement-screw technique is a convenient method to repair tibial plateau defects in primary and revision total knee arthroplasty (TKA). However, the optimal angle of screw insertions is unknown. This study aimed to perform a finite element analysis (FEA) to determine the optimal screw angle for the repair of tibial plateau defects in TKA. Methods Seven FEA models were set and two common different defects (defect 1: area < 12%, depth < 12 mm; defect 2: area > 12%, depth > 12 mm) were simulated. One screw was used in defect 1, and one or two screws were used in defect 2. Screws were parallel to the proximal cortical bone (oblique screw) or perpendicular to the upper surface (vertical screw) of the tibia. Contact stresses on cancellous bone in different areas were determined. Maximum principal stress on the cancellous bone around each screw was also compared. Results The FEA models showed that stresses on the surface of cancellous bone in tibial defect (0.13-0.39 MPa) and stress focus spot (0.45 MPa) around the screw were lower when one vertical screw was used in defect 1. The stresses on the surface of cancellous bone in tibial defect (0.09-0.44 MPa), stresses in the medial tibial plateau (0.14-0.21 MPa), and stress focus spot around the screws were lowest (0.42 MPa and 1.37 MPa) when two vertical screws were used in defect 2, followed by of one vertical and one oblique (0.16-0.48 MPa; 0.15-0.21 MPa; 1.63 MPa and 1.11 MPa). No other statistically significant differences were found. Conclusions Either for one or two screws, those perpendicular to the upper surface achieve better stability than those parallel to the proximal cortical bone of the tibia. If two vertical screws cannot be performed, one vertical and one oblique is also acceptable.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Medial-lateral translational malalignment of the prosthesis on tibial stress distribution in total knee arthroplasty: A finite element analysis
    Zheng, Zhiqian
    Liu, Yang
    Zhang, Aobo
    Chen, Hao
    Wan, Qian
    Zhong, Lei
    Wang, Xiaonan
    Han, Qing
    Wang, Jincheng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [42] Optimisation of the posterior stabilised tibial post for greater femoral rollback after total knee arthroplasty—a finite element analysis
    Nagarajan Chandran
    Farid Amirouche
    Mark H. Gonzalez
    Kevin M. Hilton
    Riad Barmada
    Wayne Goldstein
    International Orthopaedics, 2009, 33 : 687 - 693
  • [43] FINITE ELEMENT ANALYSIS MODEL VALIDATION TO EVALUATE TRABECULAR METAL TIBIAL CONES USED IN REVISION TOTAL KNEE ARTHROPLASTY
    Dharia, Mehul A.
    Stoller, Alex P.
    ASME 2013 CONFERENCE ON FRONTIERS IN MEDICAL DEVICES: APPLICATIONS OF COMPUTER MODELING AND SIMULATION, 2013,
  • [44] Cementing technique for total knee arthroplasty in cadavers using a pastry bone cement
    Boesebeck, Hans
    Holl, Anna-Maria
    Ochsner, Peter
    Groth, Manuel
    Stippich, Kevin
    Nowakowski, Andrej M.
    Egloff, Christian
    Hoechel, Sebastian
    Goepfert, Beat
    Vogt, Sebastian
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [45] Cementing technique for total knee arthroplasty in cadavers using a pastry bone cement
    Hans Bösebeck
    Anna-Maria Holl
    Peter Ochsner
    Manuel Groth
    Kevin Stippich
    Andrej M. Nowakowski
    Christian Egloff
    Sebastian Hoechel
    Beat Göpfert
    Sebastian Vogt
    Journal of Orthopaedic Surgery and Research, 16
  • [46] Prediction of Wear on Tibial Inserts Made of UHMWPE, PEEK, and CFR-PEEK in Total Knee Arthroplasty Using Finite-Element Analysis
    Koh, Yong-Gon
    Lee, Jin-Ah
    Kang, Kyoung-Tak
    LUBRICANTS, 2019, 7 (04)
  • [47] The benefits of cement augmentation of pedicle screw fixation are increased in Osteoporotic bone: A finite element analysis
    Wang W.
    Baran G.R.
    Garg H.
    Betz R.R.
    Moumene M.
    Cahill P.J.
    Spine Deformity, 2014, 2 (4) : 248 - 259
  • [48] Biomechanical investigation of the hybrid modified cortical bone screw-pedicle screw fixation technique: Finite-element analysis
    Kahaer, Alafate
    Maimaiti, Xieraili
    Maitirouzi, Julaiti
    Wang, Shuiquan
    Shi, Wenjie
    Abuduwaili, Nueraihemaiti
    Zhou, Zhihao
    Liu, Dongshan
    Maimaiti, Abulikemu
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [49] A Crossed Screw Patellar Reconstruction Technique for the Treatment of the Severely Deficient Scaphoid Shaped Patella in Total Knee Arthroplasty
    Poon, Glenys
    Siow, Wei Ming
    Poon, Kein Boon
    ARTHROPLASTY TODAY, 2023, 24
  • [50] Effect of hybrid screw placement technique on adjacent segment degeneration: a finite element analysis
    Zhang, Rui
    Xiao, Yang
    Wang, Yixi
    Chen, Qihao
    Tuoheti, Abudusalamu
    Rexiti, Paerhati
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025,