Enhancement and validation of Geant4 Brachytherapy application on clinical HDR 192Ir source

被引:9
|
作者
Ababneh, Eshraq [1 ]
Dababneh, Saed [1 ]
Qatarneh, Sharif [2 ]
Wadi-Ramahi, Shada [3 ]
机构
[1] Al Balqa Appl Univ, Dept Phys, Fac Sci, Amman 11941, Jordan
[2] North West Armed Forces Hosp, Prince Sultan Oncol Ctr, Tabuk, Saudi Arabia
[3] King Hussein Canc Ctr, Amman, Jordan
关键词
Brachytherapy; HDR; Monte Carlo simulation; Geant4; Scatter dose; MONTE-CARLO; DOSIMETRY PARAMETERS; DOSE CALCULATIONS; SIMULATIONS; ATTENUATION; ESTRO; SEEDS; WATER; AAPM;
D O I
10.1016/j.radphyschem.2014.05.040
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Geant4 Monte Carlo MC associated Brachytherapy example was adapted, enhanced and several analysis techniques have been developed. The simulation studies the isodose distribution of the total, primary and scattered doses around a Nucletron microSelectron Ir-192 source. Different phantom materials were used (water, tissue and bone) and the calculation was conducted at various depths and planes. The work provides an early estimate of the required number of primary events to ultimately achieve a given uncertainty at a given distance, in the otherwise CPU and time consuming clinical MC calculation. The adaptation of the Geant4 toolkit and the enhancements introduced to the code are all validated including the comprehensive decay of the Ir-192 source, the materials used to build the geometry, the geometry itself and the calculated scatter to primary dose ratio. The simulation quantitatively illustrates that the scattered dose in the bone medium is larger than its value in water and tissue. As the distance away from the source increases, scatter contribution to dose becomes more significant as the primary dose decreases. The developed code could be viewed as a platform that contains detailed dose calculation model for clinical application of HDR Ir-192 in Brachytherapy. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 66
页数:10
相关论文
共 50 条
  • [1] The Application of Elliptic Cylindrical Phantom in Brachytherapy Dosimetric Study of HDR 192Ir Source
    Ahn, Woo Sang
    Park, Sung Ho
    Jung, Sang Hoon
    Choi, Wonsik
    Do Ahn, Seung
    Shin, Seong Soo
    [J]. SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [2] Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source
    Ayoobian, Navid
    Asl, Akbar Sarabi
    Poorbaygi, Hosein
    Javanshir, Mohammad Reza
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 194 - 205
  • [3] Calculation of Dosimetry Parameters for 192Ir and 125I Brachytherapy Sources Using Geant4
    Fonseca-Rodrigues, Sane S. O.
    Martins, Maximiano C.
    Begalli, Marcia
    Queiroz Filho, Pedro P.
    de Souza-Santos, Denison
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1190 - 1192
  • [4] Calibration of MOSFET detectors for absolute dosimetry with an 192IR HDR brachytherapy source
    Zilio, V
    Joneja, O.
    Popowski, Y.
    Rosenfeld, A.
    Chawla, R.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 175 - 175
  • [5] Energy dependence of a radiophotoluminescent glass dosimeter for HDR 192Ir brachytherapy source
    Hashimoto, Shimpei
    Nakajima, Yujiro
    Kadoya, Noriyuki
    Abe, Kota
    Karasawa, Katsuyuki
    [J]. MEDICAL PHYSICS, 2019, 46 (02) : 964 - 972
  • [6] Audit on source strength determination for HDR and PDR 192Ir brachytherapy in Sweden
    Tedgren, Asa Carlsson
    Grindborg, Jan-Erik
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 126 - 130
  • [7] GEANT4 Simulation of 192Ir Source to Study Voxelization and Number of Event Effect on the Dose Distribution
    Zerfaoui, Mustapha
    Rrhioua, Abdeslem
    Moussa, Abdelilah
    Didi, Samir
    Tayalati, Yahya
    Hamal, Mohamed
    [J]. PROCEEDINGS OF THE MEDITERRANEAN CONFERENCE ON INFORMATION & COMMUNICATION TECHNOLOGIES 2015 (MEDCT 2015), VOL 2, 2016, 381 : 575 - 580
  • [8] On source models for 192Ir HDR brachytherapy dosimetry using model based algorithms
    Pantelis, Evaggelos
    Zourari, Kyveli
    Zoros, Emmanouil
    Lahanas, Vasileios
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (11): : 4235 - 4246
  • [9] Dose optimization of breast balloon brachytherapy using a stepping 192Ir HDR source
    Choi, Chang Hyun
    Ye, Sung-Joon
    Parsai, E. Ishmael
    Shen, Sui
    Meredith, Ruby
    Brezovich, Ivan A.
    Ove, Roger
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 90 - 102
  • [10] Attenuation due to bronchial stents in 192Ir HDR brachytherapy
    Mota, H.
    Austerlitz, C.
    Gay, H.
    Allison, R.
    Bonnerup, C.
    Downie, G.
    Sibata, C.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2420 - 2421