Calculation of Dosimetry Parameters for 192Ir and 125I Brachytherapy Sources Using Geant4

被引:0
|
作者
Fonseca-Rodrigues, Sane S. O. [1 ]
Martins, Maximiano C. [1 ]
Begalli, Marcia [2 ]
Queiroz Filho, Pedro P. [1 ]
de Souza-Santos, Denison [1 ]
机构
[1] Inst Radioprotecao & Dosimetria, Rio de Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Rio De Janeiro, Brazil
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In brachytherapy cancer treatments, methods for calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are na important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No.51. The present work is based on Monte Carlo simulations with the Geant4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source and an Iodine-125 LDR source were simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Lambda, the Geometry Factor G(r, theta), the Anisotropy Function F(r, theta) and the Radial Dose Function g(r, theta).
引用
收藏
页码:1190 / 1192
页数:3
相关论文
共 50 条
  • [1] Dosimetry of 192Ir sources used for endovascular brachytherapy
    Reynaert, N
    Van Eijkeren, M
    Taeymans, Y
    Thierens, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 499 - 516
  • [2] Enhancement and validation of Geant4 Brachytherapy application on clinical HDR 192Ir source
    Ababneh, Eshraq
    Dababneh, Saed
    Qatarneh, Sharif
    Wadi-Ramahi, Shada
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 103 : 57 - 66
  • [3] Dosimetric Study of HDR 192Ir and LDR 125I Brachytherapy Sources Using the Penelope Monte Carlo Code
    Benhabib, S. M.
    Zhu, D.
    Austerlitz, C.
    Mota, H.
    Sempau, J.
    Allison, R.
    Sibata, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [4] A standard dosimetry procedure for 192Ir sources used for endovascular brachytherapy
    Piermattei, A
    Fidanzio, A
    Azario, L
    Russo, A
    Perrone, F
    Capote, R
    Toni, MP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (23): : 4205 - 4221
  • [5] Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources
    Melhus, Christopher S.
    Rivard, Mark J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1729 - 1737
  • [6] Determination of Dose at the Reference Point for 192Ir HDR Brachytherapy Sources Using Fricke Dosimetry
    Austerlitz, Carlos
    Benhabib, Sidi
    Zhu, Dengsong
    Mota, Helvecio
    Campos, Diana
    Allison, Ron
    Sibina, Claudio
    [J]. AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2008, 31 (06): : 617 - 617
  • [7] EGSnrc Monte Carlo calculated dosimetry parameters for 192Ir and 169Yb brachytherapy sources
    Taylor, R. E. P.
    Rogers, D. W. O.
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4933 - 4944
  • [8] Radiochromic Film Based Reference Dosimetry System for 192Ir Brachytherapy Sources
    Aldelaijan, S.
    Mohammed, H.
    Tomic, N.
    Liang, L.
    Deblois, F.
    Sarfehnia, A.
    Abdel-Rahman, W.
    Seuntjens, J.
    Devic, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3574 - +
  • [9] DOSIMETRY ON TRANSVERSE AXES OF I-125 AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES
    NATH, R
    MEIGOONI, AS
    MELI, JA
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 1032 - 1040
  • [10] A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate 192Ir sources
    Guerra, A. S.
    Loreti, S.
    Pimpinella, M.
    Quini, M.
    D'Arienzo, M.
    Astefanoaei, I.
    Caporali, C.
    Bolzan, C.
    Pagliari, M.
    [J]. METROLOGIA, 2012, 49 (05) : S179 - S183