Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study

被引:25
|
作者
Yan, Shuang G. [1 ,2 ]
Chevalier, Yan [2 ]
Liu, Fanxiao [2 ,3 ]
Hua, Xingyi [1 ]
Schreiner, Anna [4 ]
Jansson, Volkmar [2 ]
Schmidutz, Florian [2 ,4 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, 1 Baicao Rd, Hefei 230088, Peoples R China
[2] Univ Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, 324 Rd Jing Wu Wei Qi, Jinan 250021, Shandong, Peoples R China
[4] Eberhard Karls Univ Tuebingen, BG Trauma Ctr Tuebingen, Schnarrenbergstr 95, D-72076 Tubingen, Germany
关键词
Stress shielding; Finite element analysis; Total hip arthroplasty; SHA; Stem; METHA SHORT STEM; PRIMARY STABILITY; DXA; AGE;
D O I
10.1186/s13018-020-02027-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Short stem total hip arthroplasty (SHA) preserves femoral bone stock and is supposed to provide a more natural load transfer compared to standard stem total hip arthroplasty (THA). As comparative biomechanical reference data are rare we used a finite element analysis (FEA) approach to compare cortical load transfer after implantations of a metaphyseal anchoring short and standard stem in native biomechanical femora. Methods The subject specific finite element models of biomechanical femora, one native and two with implanted metaphyseal anchoring SHA (Metha, B. Braun Aesculap) and standard THA (CLS, Zimmer-Biomet), were generated from computed tomography datasets. The loading configuration was performed with an axial force of 1400 N. Von Mises stress was used to investigate the change of cortical stress distribution. Results Compared to the native femur, a considerable reduction of cortical stress was recorded after implantation of SHA and standard THA. The SHA showed less reduction proximally with a significant higher metaphyseal cortical stress compared to standard THA. Moreover, the highest peak stresses were observed metaphyseal for the SHA stem while for the standard THA high stress pattern was observed more distally. Conclusions Both, short and standard THA, cause unloading of the proximal femur. However, the metaphyseal anchoring SHA features a clearly favorable pattern in terms of a lower reduction proximally and improved metaphyseal loading, while standard THA shows a higher proximal unloading and more distal load transfer. These load patterns implicate a reduced stress shielding proximally for metaphyseal anchoring SHA stems and might be able to translate in a better bone preservation.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis
    Shimasaki, Koshiro
    Nishino, Tomofumi
    Yoshizawa, Tomohiro
    Watanabe, Ryunosuke
    Hirose, Fumi
    Yasunaga, Shota
    Mishima, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [12] Development and Finite Element (FE) analysis of a novel short hip stem concept
    Jahnke, Alexander
    Harz, Torben
    Ulloa, Carlos Alfonso Fonseca
    Ishaque, Bernd Alexander
    Rickert, Markus
    JOURNAL OF ORTHOPAEDICS, 2023, 46 : 117 - 123
  • [13] A study on finite element analysis methodologies and approaches used for total hip arthroplasty
    Belwanshi, Manish
    Jayaswal, Pratesh
    Aherwar, Amit
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2596 - 2604
  • [14] Biomechanical study of the resurfacing hip arthroplasty - Finite element analysis of the femoral component
    Watanabe, Y
    Shiba, N
    Matsuo, S
    Higuchi, F
    Tagawa, Y
    Inoue, A
    JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 505 - 511
  • [15] Blood loss and transfusion rate in short stem hip arthroplasty. A comparative study
    Hochreiter, Josef
    Hejkrlik, Wilfried
    Emmanuel, Katja
    Hitzl, Wolfgang
    Ortmaier, Reinhold
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (07) : 1347 - 1353
  • [16] Blood loss and transfusion rate in short stem hip arthroplasty. A comparative study
    Josef Hochreiter
    Wilfried Hejkrlik
    Katja Emmanuel
    Wolfgang Hitzl
    Reinhold Ortmaier
    International Orthopaedics, 2017, 41 : 1347 - 1353
  • [17] A short stem with metaphyseal anchorage reveals a more physiological strain pattern compared to a standard stem - an experimental study in cadavaric bone
    Floerkemeier, Thilo
    Weltin, Jennifer
    Budde, Stefan
    Hurschler, Christof
    Windhagen, Henning
    von Lewinski, Gabriela
    Gronewold, Jens
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2019, 21 (02) : 153 - 159
  • [18] Biomechanical Behavior of an Hydroxyapatite-Coated Traditional Hip Stem and a Short One of Similar Design: Comparative Study Using Finite Element Analysis
    Gomez-Vallejo, Jesus
    Roces-Garcia, Jorge
    Moreta, Jesus
    Donaire-Hoyas, Daniel
    Gayoso, Oscar
    Marques-Lopez, Fernando
    Albareda, Jorge
    ARTHROPLASTY TODAY, 2021, 7 : 167 - 176
  • [19] Biomechanical Investigation of the Impact of Femoral Stem Size on Stress Distribution in Total Hip Arthroplasty: A Finite Element Analysis Study
    Rezaei, Shahabedine
    Rajaeirad, Mohadese
    Kamal, Zeinab
    Gilakjani, Hassan Asadi
    Khorsandi, Mohammad
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 279 - 283
  • [20] 'Pre-launch' finite element analysis of a short-stem total hip arthroplasty system consisting of two implant types
    Lerch, Matthias
    Windhagen, Henning
    Kurtz, Agnes-Elisabeth
    Budde, Stefan
    Behrens, Bernd-Arno
    Bouguecha, Anas
    Almohallami, Amer
    CLINICAL BIOMECHANICS, 2019, 61 : 31 - 37